| Total | Frontend | Backend | SimCode | Templates | Compilation | Simulation | Verification |
|---|---|---|---|---|---|---|---|
| 1677 | 1662 | 1660 | 1660 | 1660 | 1660 | 1531 | 1465 |
Test started: 2026-08-30 19:32:56
Total time taken: 9:42:57
System info: ryzen-9950x: AMD Ryzen 9 9950X3D 16-Core Processor, 124 GB RAM, Ubuntu 26.04.1 LTS
OpenModelica Version: v1.28.0-dev-509-gc3414c00ed-rust
OpenModelicaLibraryTesting Changes
| Commit | Date | Author | Summary |
|---|---|---|---|
| b6bd412 | 2026-08-30 14:23:02 +0200 | Martin Sjölund | wasm-jit: run --daeMode models in DAE mode with the me runner (#344) |
Tested Library: Buildings_12 12.1.2
{
"convertFromVersion": [
"8.0.0",
"8.1.0",
"8.1.1",
"8.1.2",
"8.1.3",
"9.0.0",
"9.1.0",
"9.1.1",
"9.1.2",
"10.0.0",
"10.1.0",
"10.1.1",
"11.0.0",
"11.1.0",
"11.1.1"
],
"path": "Buildings",
"provides": [
"12.0.0",
"12.1.0",
"12.1.1"
],
"support": "noSupport",
"uses": {
"Modelica": "4.1.0"
},
"version": "12.1.2-maint.12.x",
"zipfile": "https://github.com/lbl-srg/modelica-buildings/archive/4e96182ec2ce24ea97d8d5b345603ad26760fe60.zip"
}
BuildModel time limit: 300s
Simulation time limit: 240s
Simulation time limit for Buildings.Examples.DualFanDualDuct.ClosedLoop: 390s
Simulation time limit for Buildings.Fluid.Geothermal.ZonedBorefields.Examples.SeriesConnectedZones: 390s
Simulation time limit for Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring: 450s
Simulation time limit for Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Summer: 420s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default
Reference Files: /mnt/ReferenceFiles/Buildings/csv/maint_12.x
commit 4e96182ec2ce24ea97d8d5b345603ad26760fe60 Author: Michael WetterVerified using: OpenModelica 1.27.0~5-ga0783c0 (diffSimulationResults)
Flags:setCommandLineOptions("--simCodeTarget=wasm-jit")
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
setCFlags(getCFlags() + " -Wno-error=implicit-function-declaration")
Config: {
"extraCustomCommands": [
"setCFlags(getCFlags() + \" -Wno-error=implicit-function-declaration\")"
],
"ignoreModelPrefix": [
"Buildings.Utilities.IO.BCVTB.Examples",
"Buildings.Obsolete"
],
"library": "Buildings",
"libraryVersion": "maint.12.x",
"libraryVersionNameForTests": "12",
"referenceFileExtension": "csv",
"referenceFileNameDelimiter": "_",
"referenceFiles": "/mnt/ReferenceFiles/Buildings/csv/maint_12.x",
"runOnceBeforeTesting": [
[
"$resourceLocation/src/ThermalZones/install.py",
"--binaries-for-os-only"
]
],
"ulimitExeModels": {
"Buildings.Examples.DualFanDualDuct.ClosedLoop": 390,
"Buildings.Fluid.Geothermal.ZonedBorefields.Examples.SeriesConnectedZones": 390,
"Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Spring": 450,
"Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Summer": 420
},
"ulimitOmc": 300
}
Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.