ThermoSysPro test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
245 245 237 237 234 234 93 0

Test started: 2026-08-01 18:12:41
Total time taken: 1:48:34
System info: AMD Ryzen 9 9950X3D 16-Core Processor, 124 GB RAM, Ubuntu 24.04.4 LTS

OpenModelica Version: OMCompiler v1.26.9

FMI tool: b'warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: \'"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"<U+000A>}_\'; expected end of input\nOMSimulator v3.0.0.post160-g564cb10-linux\ninfo: 1 warnings\ninfo: 0 errors'

FMI version: 2.0

OpenModelicaLibraryTesting Changes
CommitDateAuthorSummary
6697fc02026-07-06 18:25:17 +0200linuslangenkamp[GBODE] set Radau IIA 3-stage, remove embedded error estimate (#288)

Tested Library: ThermoSysPro 4.2 warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"<U+000A>}_'; expected end of input OMSimulator v3.0.0.post160-g564cb10-linux info: 1 warnings info: 0 errors

{
 "path": "ThermoSysPro",
 "sha": "a896ab75ce22162369e7fa4ce79927eeca44ad4a",
 "support": "noSupport",
 "version": "4.2.0-master",
 "zipfile": "https://gitlab.pam-retd.fr/thermosysproandco/ThermoSysPro/-/archive/a896ab75ce22162369e7fa4ce79927eeca44ad4a/ThermoSysPro-a896ab75ce22162369e7fa4ce79927eeca44ad4a.zip"
}

BuildModel time limit: 660s
Simulation time limit: 50s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Flags:
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config:
{
 "library": "ThermoSysPro",
 "libraryVersion": "master",
 "libraryVersionNameForTests": ""
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip (sim) 40.80247.280.643.4613.123.063.95223.70289.20
ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim) 40.10240.320.643.4713.463.024.59215.79281.52
ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC (sim) 11.90111.490.612.5115.212.122.8288.83124.48
ThermoSysPro.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant 0.0015.250.632.598.251.652.760.0065.48
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_1 (sim) 0.1011.610.661.550.070.020.089.9012.88
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 (sim) 0.0612.050.631.580.080.020.0710.2913.23
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_3 (sim) 1.1612.490.621.580.380.010.0810.4414.76
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 (sim) 0.7911.430.621.540.070.020.079.7413.35
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestStaticCentrifugalPump (sim) 0.0411.500.701.550.080.020.079.7712.79
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding 0.002.320.632.090.230.000.000.003.46
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.NegativeFlow 0.002.330.622.090.240.000.000.003.48
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow 0.002.440.602.160.280.000.000.003.56
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser (sim) 0.0716.280.641.620.590.060.3113.6917.46
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicOnePhaseFlowShell (sim) 0.0916.870.641.500.480.060.1514.6918.07
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicTwoPhaseFlowPipe (sim) 0.1021.710.621.521.100.170.4018.5222.89
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestStaticCondenser (sim) 0.0513.160.721.690.150.030.3010.9914.39
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestBend (sim) 0.0811.350.671.530.120.010.069.6312.57
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestCheckValve (sim) 0.1011.140.631.490.110.010.069.4712.35
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestControlValve (sim) 0.1311.220.631.460.110.010.089.5612.45
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDiaphragm (sim) 0.0711.150.641.530.120.010.069.4312.34
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicCheckValve (sim) 0.3111.130.671.500.110.010.069.4412.59
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicReliefValve (sim) 2.4311.970.641.630.390.020.079.8715.54
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestLumpedStraightPipe (sim) 0.0412.170.611.650.350.020.0610.0913.29
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestPipePressureLoss (sim) 0.0711.330.651.590.120.010.079.5512.55
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestSwitchValve (sim) 0.0512.200.591.600.350.010.0710.1813.31
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestThreeWayValve (sim) 1.2612.020.641.440.140.020.2210.2114.42
ThermoSysPro.Examples.Book.SimpleExamples.SolarCollector.TestFresnelField (sim) 1.0052.980.621.504.170.781.3945.1355.06
ThermoSysPro.Examples.Book.SimpleExamples.SteamTurbine.TestStodolaTurbine (sim) 1.1013.460.641.600.140.010.3011.4215.67
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestDynamicDrum (sim) 0.1622.550.642.031.230.240.4818.5723.80
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestMixer3 (sim) 0.2311.600.601.470.110.010.229.7812.90
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestPressurizer (sim) 0.0413.010.681.700.400.020.0710.8214.19
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSplitter3 (sim) 0.0311.180.631.450.110.010.069.5512.32
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestStaticDrum3 (sim) 0.1620.560.621.971.020.200.3916.9821.81
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSteamDryer (sim) 0.2711.440.641.440.100.010.069.8312.83
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestTank (sim) 0.0412.190.621.480.360.020.0610.2813.32
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestVolumeATh (sim) 1.5211.760.641.640.350.010.079.6814.41
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 34.94227.250.603.2313.523.434.02203.05263.27
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 35.94222.670.593.0413.054.013.80198.77259.66
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity (sim) 0.059.890.581.510.020.010.038.3210.96
ThermoSysPro.Examples.SimpleExamples.TestBend (sim) 0.0711.290.611.430.120.010.079.6712.46
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 0.0411.820.631.470.110.020.0810.1412.96
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 0.1112.140.611.540.100.020.0810.3913.32
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump2 (sim) 1.1612.420.631.710.380.020.0710.2414.65
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim) 0.0612.900.661.730.370.030.0810.6914.08
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 0.0812.870.651.620.330.020.3210.5914.10
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 0.4111.360.611.470.070.020.069.7312.86
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 0.4312.440.631.550.380.020.0610.4213.98
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 0.1312.620.641.540.200.220.1010.5713.87
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 0.0911.070.621.430.070.010.069.5012.25
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 0.0711.400.641.540.070.020.079.7112.59
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10 (sim) 0.1611.830.661.510.140.020.279.8913.13
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim) 0.2712.500.671.640.610.020.0710.1613.93
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim) 0.2711.720.681.570.070.020.079.9913.18
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump13 (sim) 0.0911.410.651.460.070.010.079.8012.64
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution (sim) 0.0410.030.651.400.020.010.038.5711.18
ThermoSysPro.Examples.SimpleExamples.TestCheckValve (sim) 0.8013.150.621.990.250.030.1010.7815.04
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim) 0.0512.940.621.930.140.020.0910.7614.11
ThermoSysPro.Examples.SimpleExamples.TestControlValve (sim) 0.1211.310.621.480.120.010.069.6412.54
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm (sim) 0.0711.290.621.530.110.010.069.5812.45
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 0.0312.160.631.520.080.020.0710.4713.30
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 0.0411.560.641.520.090.020.089.8512.70
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 0.0512.910.671.530.180.030.2710.9114.13
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve (sim) 0.2911.610.651.530.110.010.079.8813.04
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 0.1623.730.652.151.050.190.5019.8525.01
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 0.1722.870.632.121.070.190.5118.9924.18
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum2 (sim) 0.1524.940.662.151.270.250.5120.7626.25
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum3 (sim) 0.1522.320.652.151.280.240.5018.1523.61
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum_CC (sim) 0.1622.890.632.081.270.250.4818.8024.16
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 1.2915.130.641.560.470.070.1612.8617.52
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 1.1312.290.621.660.390.020.0810.1314.51
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 0.2732.010.651.552.310.590.8726.7033.41
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 9.8860.390.652.143.910.740.8652.7471.41
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding 0.002.260.612.030.230.000.000.003.36
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim) 0.5413.000.611.430.180.200.0911.1014.62
ThermoSysPro.Examples.SimpleExamples.TestFan 0.002.030.621.620.410.000.000.003.16
ThermoSysPro.Examples.SimpleExamples.TestFan_Pin 0.002.110.611.560.550.000.000.003.22
ThermoSysPro.Examples.SimpleExamples.TestFan_Qin 0.001.970.621.550.420.000.000.003.12
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions (sim) 1.129.760.621.530.030.010.038.1611.98
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes (sim) 0.0511.230.631.570.250.020.059.3412.39
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 0.001.900.641.600.080.020.200.0010.71
ThermoSysPro.Examples.SimpleExamples.TestFresnelField (sim) 1.0654.370.651.734.741.141.4545.3156.57
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim) 0.0913.340.641.970.240.020.1011.0114.57
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim) 0.0612.010.651.590.350.010.0510.0113.18
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss (sim) 0.0710.330.611.490.110.010.068.6611.49
ThermoSysPro.Examples.SimpleExamples.TestJunctions1 (sim) 0.0412.560.631.450.140.020.2410.7213.69
ThermoSysPro.Examples.SimpleExamples.TestJunctions2 (sim) 0.0413.070.661.520.170.200.1011.0814.24
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 1.5013.650.621.920.230.030.1011.3716.24
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim) 0.2211.420.641.430.150.010.239.5912.76
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim) 2.3613.560.611.870.240.020.0911.3217.01
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker (sim) 0.1412.000.631.420.060.010.0610.4513.21
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim) 0.0412.410.631.490.310.020.0610.5313.52
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier (sim) 0.1312.050.631.560.060.010.0810.3313.29
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 0.0513.000.621.440.180.020.2611.0814.13
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 0.0412.930.651.560.150.030.2710.9114.10
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 2.4113.570.681.490.350.030.0811.6217.19
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss (sim) 0.0711.280.621.540.110.010.069.5512.46
ThermoSysPro.Examples.SimpleExamples.TestPressurizer_CC (sim) 0.0513.190.611.640.390.020.0811.0714.33
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim) 0.1212.140.611.600.330.010.0710.1213.32
ThermoSysPro.Examples.SimpleExamples.TestSensors (sim) 1.1012.380.611.610.370.010.0610.3314.58
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim) 0.0311.220.631.530.250.010.069.3812.34
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim) 0.0412.040.661.490.100.010.0710.3713.20
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss (sim) 0.0711.430.651.560.120.010.069.6812.61
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 0.0411.900.671.490.080.020.0710.2513.09
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim) 0.0511.580.631.480.110.010.069.9112.73
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump2 (sim) 0.0411.460.671.450.080.020.069.8512.64
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim) 1.109.820.641.410.020.020.038.3512.05
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 0.0713.000.651.570.160.030.3010.9514.17
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 0.0311.680.671.520.110.010.079.9612.85
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum2 (sim) 0.2511.700.661.540.110.010.089.9713.13
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases (sim) 1.1211.410.681.680.060.180.069.4313.70
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger (sim) 0.1312.100.641.560.130.020.0710.3213.36
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff (sim) 0.2711.510.621.460.090.010.069.8812.87
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer1 (sim) 0.0311.430.631.490.120.010.249.5512.59
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim) 0.2511.550.641.520.110.010.069.8412.91
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine (sim) 0.1312.010.621.510.080.010.0810.3213.23
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter (sim) 0.2611.700.641.570.120.010.269.7313.07
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 1.1113.230.681.590.180.210.1111.1415.52
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 1.3813.610.661.580.160.020.2911.5616.10
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine2 (sim) 0.1613.060.701.610.140.020.3010.9814.43
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 1.3212.780.681.570.160.020.2810.7515.27
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve (sim) 0.0511.960.651.730.380.010.079.7813.19
ThermoSysPro.Examples.SimpleExamples.TestTank (sim) 0.0412.950.651.660.390.020.0810.8014.14
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 1.2411.860.671.530.130.010.259.9314.25
ThermoSysPro.Examples.SimpleExamples.TestVolumeATh (sim) 1.5112.060.611.530.330.010.0610.1214.68
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 4.2413.620.632.030.270.030.1211.1718.97
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim) 4.2114.020.641.880.250.030.1011.7719.36
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 1.7814.390.621.970.260.040.1112.0217.25
ThermoSysPro.Examples.SimpleExamples.TestWirelessSensor (sim) 0.0413.780.651.620.420.040.2611.4414.99
ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip (sim) 39.57233.250.623.1612.822.983.71210.58273.93
ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim) 38.99235.500.603.1012.653.233.65212.87275.55
ThermoSysPro.Fluid.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC (sim) 31.98172.540.602.8125.333.593.72137.09205.57
ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant 0.0014.240.602.317.531.802.600.0062.15
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_1 (sim) 0.1611.370.641.500.320.010.059.5012.65
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 (sim) 1.1011.630.601.550.340.010.069.6713.82
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_3 (sim) 1.1112.720.641.860.260.020.0810.5014.97
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 (sim) 0.0411.470.611.570.340.010.079.4912.57
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestStaticCentrifugalPump (sim) 0.0311.940.611.620.610.010.069.6313.06
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding (sim) 1.6136.410.642.054.610.700.7728.2839.15
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.NegativeFlow (sim) 1.6436.250.592.124.340.680.6628.4638.95
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow (sim) 1.6736.960.632.014.190.570.8829.3239.74
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser (sim) 1.1415.980.622.001.000.080.1612.7418.23
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicOnePhaseFlowShell (sim) 0.0815.010.601.880.820.070.1312.1116.16
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicTwoPhaseFlowPipe (sim) 0.1321.010.591.810.940.180.4017.6822.20
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestStaticCondenser (sim) 0.1713.190.601.910.410.030.2910.5614.42
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestBend (sim) 0.1412.150.591.520.330.010.0710.2213.34
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestCheckValve (sim) 0.1111.440.621.650.310.010.069.4112.64
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestControlValve (sim) 0.1511.850.641.580.310.010.069.8913.17
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDiaphragm (sim) 0.1311.530.601.510.310.010.059.6512.73
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDynamicCheckValve (sim) 0.2911.600.621.580.310.010.069.6412.98
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDynamicReliefValve (sim) 31.0512.840.622.010.380.030.0910.3345.02
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestLumpedStraightPipe (sim) 0.0412.660.621.900.360.030.0910.2913.80
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestPipePressureLoss (sim) 0.1111.440.601.520.290.010.069.5612.60
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestSwitchValve (sim) 0.0712.370.641.960.260.010.0810.0713.55
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestThreeWayValve (sim) 1.1512.690.641.990.250.020.0910.3414.93
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.SolarCollector.TestFresnelField (sim) 1.1567.560.622.074.261.001.3958.8469.81
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.SteamTurbine.TestStodolaTurbine (sim) 1.1012.570.601.990.140.020.1010.3114.75
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestDynamicDrum (sim) 0.1924.390.622.011.540.470.2920.0825.65
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestMixer3 (sim) 0.4312.430.621.610.420.020.0810.3013.92
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestPressurizer (sim) 0.0513.060.671.840.390.030.2710.5414.24
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSplitter3 (sim) 0.0411.930.611.610.490.010.069.7613.03
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestStaticDrum3 (sim) 0.1724.040.601.971.540.420.2619.8725.25
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSteamDryer (sim) 0.4712.030.631.610.510.010.219.6913.59
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestTank (sim) 0.0412.590.611.880.380.030.2610.0413.69
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestVolumeATh (sim) 1.4412.390.621.900.450.020.269.7614.94
ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 51.96237.080.704.2615.313.444.05210.01290.25
ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 45.54230.460.634.2314.173.064.16204.84277.14
ThermoSysPro.Fluid.Examples.SimpleExamples.TestAirHumidity (sim) 0.0311.780.641.950.410.010.089.3313.00
ThermoSysPro.Fluid.Examples.SimpleExamples.TestBend (sim) 0.1411.860.691.960.420.010.099.3813.18
ThermoSysPro.Fluid.Examples.SimpleExamples.TestCHPEngineBarkantineSystem (sim) 0.0513.590.662.450.790.030.1010.2214.78
ThermoSysPro.Fluid.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 0.1912.170.711.910.470.020.089.6913.56
ThermoSysPro.Fluid.Examples.SimpleExamples.TestCheckValve (sim) 1.2713.260.692.440.380.020.3110.1015.68
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiaphragm (sim) 0.1211.600.692.010.430.010.079.0813.01
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicOnePhaseFlowPipe (sim) 0.0818.980.652.481.010.100.4314.9520.20
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger (sim) 0.7717.030.692.530.960.120.1613.2518.99
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicTwoPhaseFlowPipe (sim) 0.1836.840.702.642.260.440.7930.7038.22
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_VolumeA (sim) 0.0311.760.691.920.460.010.079.2913.03
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicCheckValve (sim) 0.2911.600.652.050.400.020.089.0613.05
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicCondenser (sim) 0.1720.810.652.501.840.140.4415.8722.14
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicDrum (sim) 2.2823.860.632.561.360.400.2419.2927.35
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicDrum_CC (sim) 0.1825.650.632.571.560.480.2920.7527.04
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicFlueGasesMultiFluidHeatExchanger (sim) 0.0717.750.631.981.060.110.1814.4118.97
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicMultiFluidHeatExchanger (sim) 2.9014.720.602.030.870.060.1311.6218.71
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicMultiFluidHeatExchangerShell (sim) 1.8414.780.601.920.820.050.1211.8617.72
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 8.0915.230.632.000.880.070.1412.1424.47
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicPlateHeatExchanger (sim) 0.9117.980.642.021.080.140.3714.3620.03
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicReliefValve (sim) 0.0413.130.631.950.300.030.1010.7514.26
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 0.2635.980.621.941.990.580.6130.8537.36
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicTwoPhaseFlowRiser (sim) 0.4022.680.611.850.970.250.4919.1224.15
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 39.1133.650.601.913.540.550.7026.9573.85
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeatingOnePipe (sim) 19.8125.600.611.972.320.460.5320.3146.48
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterSteamMultiFluidHeatExchanger (sim) 1.6318.300.621.861.180.160.3914.7221.03
ThermoSysPro.Fluid.Examples.SimpleExamples.TestFixedPowerHeatExchanger (sim) 0.1110.800.641.560.250.010.068.9212.03
ThermoSysPro.Fluid.Examples.SimpleExamples.TestFresnelField (sim) 1.3060.790.601.944.260.931.3252.3563.16
ThermoSysPro.Fluid.Examples.SimpleExamples.TestGasTurbine (sim) 0.0511.780.631.770.150.030.099.7512.92
ThermoSysPro.Fluid.Examples.SimpleExamples.TestIdealCheckValve (sim) 0.1112.750.581.790.380.030.2610.2913.89
ThermoSysPro.Fluid.Examples.SimpleExamples.TestIdealSwitchValve (sim) 0.0712.060.631.760.250.010.079.9713.21
ThermoSysPro.Fluid.Examples.SimpleExamples.TestInvSingularPressureLoss (sim) 0.0910.370.621.520.400.010.058.4011.54
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions1 (sim) 0.0412.990.631.770.470.030.2410.4814.13
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions2 (sim) 0.0613.160.591.840.350.040.2810.6614.24
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions3 (sim) 0.2313.660.621.910.660.040.1010.9514.97
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions4 (sim) 0.3611.680.591.520.410.010.069.6713.07
ThermoSysPro.Fluid.Examples.SimpleExamples.TestLoopBreaker (sim) 0.2911.760.591.480.390.010.059.8313.09
ThermoSysPro.Fluid.Examples.SimpleExamples.TestMassFlowMultiplier (sim) 0.2711.660.621.520.440.010.059.6313.00
ThermoSysPro.Fluid.Examples.SimpleExamples.TestNTUWaterHeater0 (sim) 0.6612.790.601.850.690.020.0910.1414.52
ThermoSysPro.Fluid.Examples.SimpleExamples.TestPressurizer (sim) 0.0413.060.621.940.420.030.2710.4014.22
ThermoSysPro.Fluid.Examples.SimpleExamples.TestRefP (sim) 0.2312.260.591.900.350.020.089.9113.54
ThermoSysPro.Fluid.Examples.SimpleExamples.TestRefP1 (sim) 1.1012.050.611.820.310.010.079.8414.22
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSensors (sim) 0.2712.220.621.770.250.010.289.8913.55
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser (sim) 0.0413.040.651.920.470.030.2810.3414.20
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser1 (sim) 0.0514.720.611.950.660.040.1211.9515.83
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim) 0.0311.900.591.840.370.010.079.6112.99
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleStaticCondenser (sim) 0.0411.530.641.520.240.010.069.6912.64
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSingularPressureLoss (sim) 0.1011.150.591.590.260.010.069.2412.31
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser (sim) 0.0412.360.621.780.450.030.249.8613.49
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim) 1.1011.260.611.530.270.010.069.4013.44
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCondenser (sim) 0.3213.040.611.850.410.030.2610.5014.45
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCondenserHEI (sim) 0.8313.130.581.730.410.040.2810.6815.00
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticDrum1 (sim) 0.0412.310.591.770.190.020.0710.2613.40
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticDrum2 (sim) 0.4612.150.602.050.220.020.079.7813.66
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticExchangerDTorWorEff (sim) 0.3911.910.631.590.600.010.069.6513.38
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticExchangerKS (sim) 0.0311.500.571.580.340.010.069.5112.58
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticFan 0.002.580.601.880.700.000.000.003.66
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticPlateHeatExchanger (sim) 0.1412.190.611.560.250.020.0810.2913.40
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticWallFlueGasesExchanger (sim) 0.4213.420.651.860.190.050.1111.2114.96
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamDryer1 (sim) 0.0412.040.621.820.380.010.079.7613.16
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamDryer2 (sim) 0.4712.250.621.560.500.010.229.9513.83
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamEngine (sim) 0.1612.320.641.820.130.020.0910.2613.59
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamExtractionSplitter (sim) 0.5112.380.591.810.250.010.0710.2413.95
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 0.0413.650.641.860.280.030.1111.3714.81
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStodolaTurbine2 (sim) 1.1212.680.601.900.140.020.1010.5214.90
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSwitchValve (sim) 0.0712.310.641.910.270.020.0810.0213.50
ThermoSysPro.Fluid.Examples.SimpleExamples.TestTank (sim) 1.1112.520.631.790.350.020.0810.2814.71
ThermoSysPro.Fluid.Examples.SimpleExamples.TestTankHorizontal (sim) 0.0413.300.621.820.440.030.2610.7614.42
ThermoSysPro.Fluid.Examples.SimpleExamples.TestThreeWayValve (sim) 1.7912.320.641.820.240.020.0910.1515.24
ThermoSysPro.Fluid.Examples.SimpleExamples.TestVolumeA (sim) 4.9812.910.631.920.390.030.2610.3118.99
ThermoSysPro.Fluid.Examples.SimpleExamples.TestVolumeI (sim) 0.0513.090.601.930.370.030.2610.5114.19
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_IF97 (sim) 2.0412.840.621.580.360.020.0710.8116.00
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_polynomial (sim) 0.0412.850.631.630.410.020.0810.7214.00
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_IF97 (sim) 1.2112.120.661.610.370.020.0710.0514.48
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_polynomial (sim) 0.0312.070.661.700.370.010.079.9213.23
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test3_IF97 (sim) 0.0513.380.651.950.250.030.1111.0414.56
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_T (sim) 0.028.450.661.450.010.000.026.979.64
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_d (sim) 0.038.300.611.390.010.000.026.889.39
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_h (sim) 0.099.950.611.410.070.010.058.4211.12
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_p (sim) 0.0810.360.601.390.070.010.068.8311.49