/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_IDEAS_IDEAS_Fluid_HeatExchangers_Examples_EmbeddedPipeDp_fmu --startTime=0 --stopTime=10000 --stepSize=4 --timeout=50 --tolerance=1e-06 IDEAS_IDEAS_Fluid_HeatExchangers_Examples_EmbeddedPipeDp.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatExchangers.Examples.EmbeddedPipeDp" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatExchangers.Examples.EmbeddedPipeDp" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatExchangers.Examples.EmbeddedPipeDp/model-lm96nvie" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/IDEAS_IDEAS.Fluid.HeatExchangers.Examples.EmbeddedPipeDp" info: *** FMU Simulation Info *** - model: model (model exchange) - path: IDEAS_IDEAS_Fluid_HeatExchangers_Examples_EmbeddedPipeDp.fmu - startTime: 0.000000 - stopTime: 10000.000000 - tolerance: 0.000001 - stepSize: 4.000000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 4.0.0/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in EmbeddedPipeDp.pump: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." info: maximum step size for 'model.root': 4.000000 info: Result file: model_res.mat (bufferSize=10) info: Final Statistics for 'model.root': NumSteps = 719 NumRhsEvals = 728 NumLinSolvSetups = 42 NumNonlinSolvIters = 727 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 2 warnings info: 0 errors