/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU_fmu --startTime=0 --stopTime=7200 --stepSize=2.88 --timeout=50 --tolerance=1e-06 AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.GenericAHU" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.GenericAHU" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.GenericAHU/model-k61ukdh3" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Systems.ModularAHU.Examples.GenericAHU" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.fmu - startTime: 0.000000 - stopTime: 7200.000000 - tolerance: 0.000001 - stepSize: 2.880000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanSup.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanSup: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:391:3-398:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((genericAHU.fanRet.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in GenericAHU.genericAHU.fanRet: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:83:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eta, has value: -2.89462e-12" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.heaDis.etaHyd, has value: -4.34644e-09" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 2.1.1/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= genericAHU.preheater.hydraulicModule.PumpInterface.pump.eff.yMot, has value: -3.38214e-14" info: maximum step size for 'model.root': 2.880000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.cooler.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.heater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModule.pipe1.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModule.pipe2.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModule.pipe3.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModule.pipe4.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModule.pipe5.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModule.pipe6.pipeModel will not be stored in the result file, because the signal type is not supported info: Variable model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModule.pipeModel will not be stored in the result file, because the signal type is not supported info: Parameter model.root.AixLib_AixLib_Systems_ModularAHU_Examples_GenericAHU.genericAHU.preheater.hydraulicModuleIcon will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 2826 NumRhsEvals = 3091 NumLinSolvSetups = 204 NumNonlinSolvIters = 3090 NumNonlinSolvConvFails = 2 NumErrTestFails = 22 info: 2 warnings info: 0 errors