python3 -m fmpy simulate --output-file Buildings_12_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage_res.csv --start-time 0 --stop-time 345600 --timeout 400 --relative-tolerance 1e-06 --interface-type ModelExchange --solver CVode --output-interval 125.445 Buildings_12_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/HeatExchangers/BaseClasses/PartialEffectivenessNTU.mo:112:5-117:36:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pla.hexCoo.Q_flow_nominal / (300.05 - pla.hexCoo.T_a2_nominal) >= 0.0)) --> "In AllElectricCWStorage.pla.hexCoo: Q_flow_nominal is defined with the wrong sign. By convention, a positive value describes a heat flow from Medium1 to Medium2. The parameter T_a1_nominal should then be larger than T_a2_nominal.Future version of this library might enforce this convention and throw an error." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumChiWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.etaHyd, has value: -1.54008e-45" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumHeaWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumHeaWat.pum.etaHyd, has value: -1.32773e-42" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatCon.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatCon.pum.etaHyd, has value: -1.01043e-46" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatEva.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.etaHyd, has value: -4.60589e-40"