/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_11_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage_res.mat --tempDir=temp_Buildings_11_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage_fmu --startTime=0 --stopTime=345600 --stepSize=126.826 --timeout=400 --tolerance=1e-06 Buildings_11_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 3, column 2: syntax error while parsing value - invalid literal; last read: '"temp_AixLib_AixLib_Fluid_HeatPumps_Validation_ReciprocatingWaterToWater_Static_fmu"}_'; expected end of input info: Set temp directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage" info: New model "model" with corresponding temp directory "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage/model-87959o2e" info: Set working directory to "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_11_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage.fmu - startTime: 0.000000 - stopTime: 345600.000000 - tolerance: 0.000001 - stepSize: 126.826000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumChiWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumChiWat.pum.etaHyd, has value: -1.25038e-40" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumHeaWat.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumHeaWat.pum.etaHyd, has value: -9.41199e-41" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.1-maint.11.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.pumConWatEva.pum.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.pumConWatEva.pum.etaHyd, has value: -7.25537e-42" info: maximum step size for 'model.root': 126.826000 info: Result file: Buildings_11_Buildings.DHC.Plants.Combined.Validation.AllElectricCWStorage_res.mat (bufferSize=1) info: Parameter model.root.Buildings_11_Buildings_DHC_Plants_Combined_Validation_AllElectricCWStorage.pla.heaPum.heaPum.aleMes.message will not be stored in the result file, because the signal type is not supported