| Total | Frontend | Backend | SimCode | Templates | Compilation | Simulation | Verification |
|---|---|---|---|---|---|---|---|
| 1677 | 1573 | 1572 | 1572 | 1564 | 1564 | 1414 | 1359 |
Test started: 2025-11-24 02:41:30
Total time taken: 20:28:17
System info: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 22.04.5 LTS
OpenModelica Version: OMCompiler v1.24.5-v1.24.5.1+gb17346080d
FMI tool: b"usage: __main__.py [-h] [--version] [--validate] [--start-time START_TIME] FMPy version: 0.3.21 Python version: 3.10.12 (main, Aug 15 2025, 14:32:43) [GCC 11.4.0] --version show program's version number and exit"
FMI version: 2.0
OpenModelicaLibraryTesting Changes| Commit | Date | Author | Summary |
|---|---|---|---|
| 0e9a9de | 2025-11-20 12:59:33 +0100 | Andreas | Adding TILMedia_AddOn_Tests (#253) |
Tested Library: Buildings_12 12.1.1 usage: __main__.py [-h] [--version] [--validate] [--start-time START_TIME] FMPy version: 0.3.21 Python version: 3.10.12 (main, Aug 15 2025, 14:32:43) [GCC 11.4.0] --version show program's version number and exit
{
"convertFromVersion": [
"8.0.0",
"8.1.0",
"8.1.1",
"8.1.2",
"8.1.3",
"9.0.0",
"9.1.0",
"9.1.1",
"9.1.2",
"10.0.0",
"10.1.0",
"10.1.1",
"11.0.0",
"11.1.0"
],
"path": "Buildings",
"provides": [
"12.0.0",
"12.1.0"
],
"support": "noSupport",
"uses": {
"Modelica": "4.0.0"
},
"version": "12.1.1-maint.12.x",
"zipfile": "https://github.com/lbl-srg/modelica-buildings/archive/8a252a1e5ec2e46051ed52e215be1c8863a135ef.zip"
}
BuildModel time limit: 300s
Simulation time limit: 400s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default
Reference Files: /mnt/ReferenceFiles/Buildings/csv/maint_12.x
commit 8a252a1e5ec2e46051ed52e215be1c8863a135ef Author: Michael WetterVerified using: OpenModelica 1.25.0~dev-371-g1c5c528 (diffSimulationResults)
Flags:setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config: {
"ignoreModelPrefix": [
"Buildings.Utilities.IO.BCVTB.Examples",
"Buildings.Obsolete"
],
"library": "Buildings",
"libraryVersion": "maint.12.x",
"libraryVersionNameForTests": "12",
"referenceFileExtension": "csv",
"referenceFileNameDelimiter": "_",
"referenceFiles": "/mnt/ReferenceFiles/Buildings/csv/maint_12.x",
"runOnceBeforeTesting": [
[
"$resourceLocation/src/ThermalZones/install.py",
"--binaries-for-os-only"
]
],
"ulimitExe": 400,
"ulimitOmc": 300
}
Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.