Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo", uses=false) Using package ThermoSysPro with version 4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo) Running command: translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50") translateModel(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50,tolerance=0.001,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/package.mo): time 0.8441/0.8441, allocations: 150.9 MB / 166.5 MB, free: 14.39 MB / 142.1 MB Notification: Performance of FrontEnd - loaded program: time 0.0003007/0.0003007, allocations: 13.16 kB / 237.1 MB, free: 1.934 MB / 190.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.05446/0.05477, allocations: 31.34 MB / 268.5 MB, free: 7.137 MB / 222.1 MB Notification: Automatically loaded package Complex 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package ModelicaServices 4.0.0 due to uses annotation from Modelica. Notification: Automatically loaded package Modelica 4.0.0 due to usage. Notification: Performance of NFInst.instantiate(ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50): time 1.686/1.741, allocations: 377.4 MB / 0.6308 GB, free: 10.45 MB / 0.5137 GB Notification: Performance of NFInst.instExpressions: time 0.5523/2.294, allocations: 228.9 MB / 0.8544 GB, free: 8.348 MB / 0.6231 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01452/2.308, allocations: 217.6 kB / 0.8546 GB, free: 8.316 MB / 0.6231 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:35:3-37:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeB.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:96:3-98:48:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:99:3-101:48:writable] Warning: Connector Cm is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:102:3-104:50:writable] Warning: Connector Cd is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:105:3-107:46:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:121:3-123:47:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:124:3-126:49:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/DynamicDrum.mo:127:3-129:47:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SinkP.mo:16:3-18:16:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:89:3-91:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/HeatExchangers/StaticWallFlueGasesExchanger.mo:94:3-95:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:184:3-185:48:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/DynamicTwoPhaseFlowPipe.mo:188:3-189:46:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:35:3-36:82:writable] Warning: Connector Cfg1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:37:3-39:17:writable] Warning: Connector Cfg2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:40:3-42:16:writable] Warning: Connector Cws1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/MultiFluids/HeatExchangers/DynamicExchangerWaterSteamFlueGases.mo:43:3-44:83:writable] Warning: Connector Cws2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:59:3-61:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:62:3-63:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StodolaTurbine.mo:67:3-71:23:writable] Warning: Connector M is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:89:3-90:45:writable] Warning: Connector Cv is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:91:3-92:46:writable] Warning: Connector Cl is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:99:3-100:48:writable] Warning: Connector Cee is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/HeatExchangers/SimpleDynamicCondenser.mo:101:3-102:43:writable] Warning: Connector Cse is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourceQ.mo:24:3-25:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SinkP.mo:33:3-34:47:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:25:3-27:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:28:3-30:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:31:3-33:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeA.mo:38:3-40:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:16:3-18:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Junctions/MassFlowMultiplier.mo:19:3-20:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:60:3-62:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Machines/StaticCentrifugalPump.mo:63:3-65:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:19:3-21:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Sensors/SensorQ.mo:22:3-24:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:35:3-37:42:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/PipePressureLoss.mo:38:3-40:37:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:29:3-31:42:writable] Warning: Connector Ce is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:32:3-34:37:writable] Warning: Connector Cs1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:35:3-37:43:writable] Warning: Connector Cs2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeD.mo:38:3-40:37:writable] Warning: Connector Cs3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:29:3-31:42:writable] Warning: Connector Ce1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:32:3-34:37:writable] Warning: Connector Ce2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:35:3-37:37:writable] Warning: Connector Cs is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/Volumes/VolumeC.mo:38:3-40:43:writable] Warning: Connector Ce3 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:45:3-47:43:writable] Warning: Connector C1 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/PressureLosses/ControlValve.mo:48:3-50:38:writable] Warning: Connector C2 is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/BoundaryConditions/FuelSourcePQ.mo:21:3-22:65:writable] Warning: Connector C is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/WaterSteam/BoundaryConditions/SourcePQ.mo:29:3-30:52:writable] Warning: Connector C is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/SourcePQ.mo:18:3-19:83:writable] Warning: Connector C is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/AirHumidity.mo:33:3-35:16:writable] Warning: Connector C1 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/BoundaryConditions/AirHumidity.mo:42:3-43:83:writable] Warning: Connector C2 is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/Compressor.mo:50:3-52:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/Compressor.mo:53:3-55:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:101:3-103:16:writable] Warning: Connector Cfuel is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:104:3-106:16:writable] Warning: Connector Ca is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:107:3-108:83:writable] Warning: Connector Cfg is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Combustion/CombustionChambers/GTCombustionChamber.mo:109:3-111:17:writable] Warning: Connector Cws is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/CombustionTurbine.mo:33:3-35:16:writable] Warning: Connector Ce is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/Machines/CombustionTurbine.mo:36:3-38:52:writable] Warning: Connector Cs is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/TAC/GasTurbine.mo:63:3-64:83:writable] Warning: Connector Entree_air is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/TAC/GasTurbine.mo:65:3-66:81:writable] Warning: Connector Sortie_fumees is not balanced: The number of potential variables (7) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/TAC/GasTurbine.mo:67:3-69:17:writable] Warning: Connector Entree_eau_combustion is not balanced: The number of potential variables (4) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/FlueGases/TAC/GasTurbine.mo:70:3-71:82:writable] Warning: Connector Entree_combustible is not balanced: The number of potential variables (14) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.01532/2.324, allocations: 4.658 MB / 0.8591 GB, free: 4.414 MB / 0.6231 GB Notification: Performance of NFTyping.typeBindings: time 0.03509/2.359, allocations: 13.17 MB / 0.872 GB, free: 9.516 MB / 0.6387 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:783:9-783:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:850:9-850:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1088:9-1088:27:writable] Warning: cv was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph.mo:69:3-69:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du1satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ph_der.mo:167:3-170:49:writable] Warning: du2satp_der was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteam/IF97_packages.mo:1445:9-1445:35:writable] Warning: h was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh1satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoSysPro 4.0.0-master/Properties/WaterSteamSimple/prop4_Ps.mo:71:3-71:60:writable] Warning: dh2satp was used before it was defined (given a value). Additional such uses may exist for the variable, but some messages were suppressed. Notification: Performance of NFTyping.typeClassSections: time 0.06915/2.428, allocations: 28.08 MB / 0.8994 GB, free: 14.07 MB / 0.67 GB Notification: Performance of NFFlatten.flatten: time 0.09385/2.522, allocations: 84.38 MB / 0.9818 GB, free: 9.422 MB / 0.7481 GB Notification: Performance of NFFlatten.resolveConnections: time 0.7613/3.283, allocations: 29.05 MB / 1.01 GB, free: 31.54 MB / 0.7638 GB Notification: Performance of NFEvalConstants.evaluate: time 0.03915/3.322, allocations: 28.38 MB / 1.038 GB, free: 29.85 MB / 0.7638 GB Notification: Performance of NFSimplifyModel.simplify: time 0.04968/3.372, allocations: 31.68 MB / 1.069 GB, free: 26.32 MB / 0.7638 GB Notification: Performance of NFPackage.collectConstants: time 0.02151/3.393, allocations: 6.182 MB / 1.075 GB, free: 26.32 MB / 0.7638 GB Notification: Performance of NFFlatten.collectFunctions: time 0.06815/3.462, allocations: 35 MB / 1.109 GB, free: 26.32 MB / 0.7638 GB Notification: Performance of NFScalarize.scalarize: time 0.02885/3.491, allocations: 17.76 MB / 1.126 GB, free: 24.85 MB / 0.7638 GB Notification: Performance of NFVerifyModel.verify: time 0.05087/3.541, allocations: 26.02 MB / 1.152 GB, free: 4.441 MB / 0.7638 GB Notification: Performance of NFConvertDAE.convert: time 0.1212/3.663, allocations: 82.23 MB / 1.232 GB, free: 5.156 MB / 0.8419 GB Notification: Performance of FrontEnd - DAE generated: time 5.731e-06/3.663, allocations: 4.688 kB / 1.232 GB, free: 5.152 MB / 0.8419 GB Notification: Performance of FrontEnd: time 1.723e-06/3.663, allocations: 0 / 1.232 GB, free: 5.152 MB / 0.8419 GB Notification: Performance of Transformations before backend: time 0.001902/3.665, allocations: 0.8438 kB / 1.232 GB, free: 5.152 MB / 0.8419 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 10973 * Number of variables: 10973 Notification: Performance of Generate backend data structure: time 0.2303/3.895, allocations: 58.26 MB / 1.289 GB, free: 11.08 MB / 0.9044 GB Notification: Performance of prepare preOptimizeDAE: time 4.968e-05/3.895, allocations: 12.88 kB / 1.289 GB, free: 11.07 MB / 0.9044 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02129/3.916, allocations: 4.418 MB / 1.293 GB, free: 6.629 MB / 0.9044 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.04401/3.96, allocations: 16.77 MB / 1.31 GB, free: 6.965 MB / 0.92 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.01812/3.978, allocations: 12.07 MB / 1.321 GB, free: 9.18 MB / 0.9357 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01732/3.996, allocations: 2.976 MB / 1.324 GB, free: 6.203 MB / 0.9357 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.9717/4.968, allocations: 71.31 MB / 1.394 GB, free: 200.2 MB / 0.9514 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.001428/4.969, allocations: 44.16 kB / 1.394 GB, free: 200.2 MB / 0.9514 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.01513/4.984, allocations: 1.185 MB / 1.395 GB, free: 200.2 MB / 0.9514 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001278/4.985, allocations: 1.34 MB / 1.397 GB, free: 200.2 MB / 0.9514 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.2381/5.224, allocations: 87.94 MB / 1.482 GB, free: 167.4 MB / 0.9514 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.8994/6.123, allocations: 265.3 MB / 1.742 GB, free: 451.2 MB / 1.014 GB Notification: Performance of preOpt comSubExp (simulation): time 0.1612/6.284, allocations: 73.1 MB / 1.813 GB, free: 433.6 MB / 1.014 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.118/6.402, allocations: 53.07 MB / 1.865 GB, free: 411.1 MB / 1.014 GB Notification: Performance of preOpt evalFunc (simulation): time 0.2741/6.676, allocations: 157.2 MB / 2.018 GB, free: 244.2 MB / 1.014 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.1324/6.809, allocations: 56.03 MB / 2.073 GB, free: 188.1 MB / 1.014 GB Notification: Performance of pre-optimization done (n=7409): time 7.033e-05/6.809, allocations: 0 / 2.073 GB, free: 188.1 MB / 1.014 GB Notification: Performance of matching and sorting (n=7417): time 1.411/8.22, allocations: 351 MB / 2.416 GB, free: 430.4 MB / 1.014 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0003286/8.221, allocations: 0.9913 MB / 2.417 GB, free: 429.3 MB / 1.014 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.01266/8.233, allocations: 9.443 MB / 2.426 GB, free: 420 MB / 1.014 GB Notification: Performance of collectPreVariables (initialization): time 0.01237/8.246, allocations: 0.6774 MB / 2.427 GB, free: 419.3 MB / 1.014 GB Notification: Performance of collectInitialEqns (initialization): time 0.006632/8.253, allocations: 7.997 MB / 2.434 GB, free: 412.2 MB / 1.014 GB Notification: Performance of collectInitialBindings (initialization): time 0.02847/8.281, allocations: 26.13 MB / 2.46 GB, free: 388.5 MB / 1.014 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.04409/8.325, allocations: 9.507 MB / 2.469 GB, free: 379 MB / 1.014 GB Notification: Performance of setup shared object (initialization): time 3.807e-05/8.325, allocations: 307.8 kB / 2.469 GB, free: 378.7 MB / 1.014 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.1066/8.432, allocations: 44.36 MB / 2.513 GB, free: 334.6 MB / 1.014 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.1149/8.547, allocations: 50.73 MB / 2.562 GB, free: 282.9 MB / 1.014 GB Notification: It was not possible to check the given initialization system for consistency symbolically, because the relevant equations are part of an algebraic loop. This is not supported yet. Notification: Performance of analyzeInitialSystem (initialization): time 1.366/9.913, allocations: 299.9 MB / 2.855 GB, free: 396.5 MB / 1.014 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0001798/9.913, allocations: 32.25 kB / 2.855 GB, free: 396.5 MB / 1.014 GB Notification: Performance of matching and sorting (n=8175) (initialization): time 0.4176/10.33, allocations: 150.2 MB / 3.002 GB, free: 281.3 MB / 1.014 GB Notification: Performance of prepare postOptimizeDAE: time 0.0002526/10.33, allocations: 100.7 kB / 3.002 GB, free: 281.2 MB / 1.014 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0007285/10.33, allocations: 210.1 kB / 3.002 GB, free: 281 MB / 1.014 GB Notification: Performance of postOpt tearingSystem (initialization): time 5.004/15.34, allocations: 2.259 GB / 5.261 GB, free: 322.7 MB / 1.014 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01962/15.36, allocations: 3.495 MB / 5.264 GB, free: 320.2 MB / 1.014 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.461/15.82, allocations: 192.8 MB / 5.453 GB, free: 171 MB / 1.014 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.05929/15.88, allocations: 6.087 MB / 5.459 GB, free: 167.1 MB / 1.014 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.01537/15.89, allocations: 1.965 MB / 5.46 GB, free: 165.6 MB / 1.014 GB Warning: Assuming fixed start value for the following 5 variables: regulation_Niveau_HP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_MP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_BP.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0:DISCRETE(fixed = true protected = true ) type: Real Warning: The initial conditions are over specified. The following 4 initial equations are redundant, so they are removed from the initialization system: $DER.EconomiseurHP3.TwoPhaseFlowPipe.Q[4] = 0.0 $DER.SurchauffeurHP2.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurHP3.TwoPhaseFlowPipe.Q[1] = 0.0 $DER.SurchauffeurMP3.TwoPhaseFlowPipe.Q[1] = 0.0. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 437 * Number of states: 0 () * Number of discrete variables: 281 ($PRE.regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_HP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,$PRE.regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.reset.signal,regulation_Niveau_BP.pIsat.Integrateur1.reset.signal,regulation_Niveau_MP.pIsat.Integrateur1.reset.signal,regulation_Niveau_HP.pIsat.Integrateur1.reset.signal,regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal,$PRE.regulation_Niveau_Condenseur.edge.uL.signal,$whenCondition1,GasTurbine.TurbineAgaz.Cs.b,GasTurbine.TurbineAgaz.Ce.a,GasTurbine.chambreCombustionTAC.Cws.a,GasTurbine.chambreCombustionTAC.Cfg.b,GasTurbine.chambreCombustionTAC.Ca.a,GasTurbine.chambreCombustionTAC.Cfuel.a,GasTurbine.Compresseur.Cs.b,GasTurbine.Compresseur.Ce.a,GasTurbine.xAIR.C2.b,GasTurbine.xAIR.C1.a,SourceFumees.C.b,sourceEau.C.b,sourceCombustible.C.b,vanne_entree_TurbineMP.C2.b,vanne_entree_TurbineMP.C1.a,MelangeurPreTMP.Ce3.a,MelangeurPreTMP.Cs.b,MelangeurPreTMP.Ce2.a,MelangeurPreTMP.Ce1.a,VolumePreTHP.Cs3.b,VolumePreTHP.Cs2.b,VolumePreTHP.Cs1.b,VolumePreTHP.Ce.a,Vanne_alimentationMPHP2.C2.b,Vanne_alimentationMPHP2.C1.a,Vanne_alimentationMPHP1.C2.b,Vanne_alimentationMPHP1.C1.a,VolumeECO_HP2_3.Ce3.a,VolumeECO_HP2_3.Cs.b,VolumeECO_HP2_3.Ce2.a,VolumeECO_HP2_3.Ce1.a,VolumeECO_HP1_2.Ce3.a,VolumeECO_HP1_2.Cs.b,VolumeECO_HP1_2.Ce2.a,VolumeECO_HP1_2.Ce1.a,vanne_entree_TurbineHP.C2.b,vanne_entree_TurbineHP.C1.a,lumpedStraightPipeK2.C2.b,lumpedStraightPipeK2.C1.a,CapteurDebitVapCondenseur.C2.b,CapteurDebitVapCondenseur.C1.a,CapteurDebitEauCondenseur.C2.b,CapteurDebitEauCondenseur.C1.a,CapteurDebitEauBPsortie.C2.b,CapteurDebitEauBPsortie.C1.a,CapteurDebitEauBP.C2.b,CapteurDebitEauBP.C1.a,CapteurDebitVapBP.C2.b,CapteurDebitVapBP.C1.a,CapteurDebitVapMP.C2.b,CapteurDebitVapMP.C1.a,CapteurDebitEauMP.C2.b,CapteurDebitEauMP.C1.a,CapteurDebitEauHP.C2.b,CapteurDebitEauHP.C1.a,CapteurDebitVapHP.C2.b,CapteurDebitVapHP.C1.a,vanne_extraction.C2.b,vanne_extraction.C1.a,perteChargeK2.C2.b,perteChargeK2.C1.a,PompeAlimBP.C2.b,PompeAlimBP.C1.a,perteChargeK.C2.b,perteChargeK.C1.a,perteChargeK8.C2.b,perteChargeK8.C1.a,perteChargeK3.C2.b,perteChargeK3.C1.a,PerteChargeZero2.C2.b,PerteChargeZero2.C1.a,DoubleDebitBP.Cs.b,DoubleDebitBP.Ce.a,MoitieDebitBP.Cs.b,MoitieDebitBP.Ce.a,PompeAlimHP.C2.b,PompeAlimHP.C1.a,PompeAlimMP.C2.b,PompeAlimMP.C1.a,VolumeAlimMPHP.Cs2.b,VolumeAlimMPHP.Cs1.b,VolumeAlimMPHP.Ce2.a,VolumeAlimMPHP.Ce1.a,perteChargeKCond1.C2.b,perteChargeKCond1.C1.a,VolumeCond1.Ce3.a,VolumeCond1.Cs.b,VolumeCond1.Ce2.a,VolumeCond1.Ce1.a,perteChargeK1.C2.b,perteChargeK1.C1.a,PuitsCaloporteur.C.a,SourceCaloporteur.C.b,Condenseur.Cse.b,Condenseur.Cee.a,Condenseur.Cl.b,Condenseur.Cv.a,MoitieDebitHP.Cs.b,MoitieDebitHP.Ce.a,DoubleDebitMP.Cs.b,DoubleDebitMP.Ce.a,DoubleDebitHP.Cs.b,DoubleDebitHP.Ce.a,TurbineBP.Cs.b,TurbineBP.Ce.a,MelangeurPostTMP1.Ce3.a,MelangeurPostTMP1.Cs.b,MelangeurPostTMP1.Ce2.a,MelangeurPostTMP1.Ce1.a,TurbineMP.Cs.b,TurbineMP.Ce.a,TurbineHP.Cs.b,TurbineHP.Ce.a,EconomiseurBP.TwoPhaseFlowPipe.C2.b,EconomiseurBP.TwoPhaseFlowPipe.C1.a,EconomiseurBP.ExchangerFlueGasesMetal.C2.b,EconomiseurBP.ExchangerFlueGasesMetal.C1.a,PuitsFumees.C.a,SurchauffeurBP.TwoPhaseFlowPipe.C2.b,SurchauffeurBP.TwoPhaseFlowPipe.C1.a,SurchauffeurBP.ExchangerFlueGasesMetal.C2.b,SurchauffeurBP.ExchangerFlueGasesMetal.C1.a,Vanne_alimentationMPHP.C2.b,Vanne_alimentationMPHP.C1.a,EvaporateurBP.TwoPhaseFlowPipe.C2.b,EvaporateurBP.TwoPhaseFlowPipe.C1.a,EvaporateurBP.ExchangerFlueGasesMetal.C2.b,EvaporateurBP.ExchangerFlueGasesMetal.C1.a,VolumeEvapBP.Ce3.a,VolumeEvapBP.Cs.b,VolumeEvapBP.Ce2.a,VolumeEvapBP.Ce1.a,GainChargeBP.C2.b,GainChargeBP.C1.a,vanne_alimentationBP.C2.b,vanne_alimentationBP.C1.a,vanne_vapeurBP.C2.b,vanne_vapeurBP.C1.a,BallonBP.Cs.b,BallonBP.Ce3.a,BallonBP.Ce2.a,BallonBP.Cv.b,BallonBP.Cd.b,BallonBP.Cm.a,BallonBP.Ce1.a,SurchauffeurMP3.TwoPhaseFlowPipe.C2.b,SurchauffeurMP3.TwoPhaseFlowPipe.C1.a,SurchauffeurMP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurMP2.TwoPhaseFlowPipe.C2.b,SurchauffeurMP2.TwoPhaseFlowPipe.C1.a,SurchauffeurMP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP2.ExchangerFlueGasesMetal.C1.a,MelangeurHPMP.Cs2.b,MelangeurHPMP.Cs1.b,MelangeurHPMP.Ce2.a,MelangeurHPMP.Ce1.a,SurchauffeurMP1.TwoPhaseFlowPipe.C2.b,SurchauffeurMP1.TwoPhaseFlowPipe.C1.a,SurchauffeurMP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurMP1.ExchangerFlueGasesMetal.C1.a,EconomiseurMP.TwoPhaseFlowPipe.C2.b,EconomiseurMP.TwoPhaseFlowPipe.C1.a,EconomiseurMP.ExchangerFlueGasesMetal.C2.b,EconomiseurMP.ExchangerFlueGasesMetal.C1.a,VolumeEvapMP.Ce3.a,VolumeEvapMP.Cs.b,VolumeEvapMP.Ce2.a,VolumeEvapMP.Ce1.a,GainChargeMP.C2.b,GainChargeMP.C1.a,EvaporateurMP.TwoPhaseFlowPipe.C2.b,EvaporateurMP.TwoPhaseFlowPipe.C1.a,EvaporateurMP.ExchangerFlueGasesMetal.C2.b,EvaporateurMP.ExchangerFlueGasesMetal.C1.a,vanne_vapeurMP.C2.b,vanne_vapeurMP.C1.a,vanne_alimentationMP.C2.b,vanne_alimentationMP.C1.a,BallonMP.Cs.b,BallonMP.Ce3.a,BallonMP.Ce2.a,BallonMP.Cv.b,BallonMP.Cd.b,BallonMP.Cm.a,BallonMP.Ce1.a,SurchauffeurHP3.TwoPhaseFlowPipe.C2.b,SurchauffeurHP3.TwoPhaseFlowPipe.C1.a,SurchauffeurHP3.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP2.TwoPhaseFlowPipe.C2.b,SurchauffeurHP2.TwoPhaseFlowPipe.C1.a,SurchauffeurHP2.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP2.ExchangerFlueGasesMetal.C1.a,EconomiseurHP1.TwoPhaseFlowPipe.C2.b,EconomiseurHP1.TwoPhaseFlowPipe.C1.a,EconomiseurHP1.ExchangerFlueGasesMetal.C2.b,EconomiseurHP1.ExchangerFlueGasesMetal.C1.a,EconomiseurHP2.TwoPhaseFlowPipe.C2.b,EconomiseurHP2.TwoPhaseFlowPipe.C1.a,EconomiseurHP2.ExchangerFlueGasesMetal.C2.b,EconomiseurHP2.ExchangerFlueGasesMetal.C1.a,EconomiseurHP3.TwoPhaseFlowPipe.C2.b,EconomiseurHP3.TwoPhaseFlowPipe.C1.a,EconomiseurHP3.ExchangerFlueGasesMetal.C2.b,EconomiseurHP3.ExchangerFlueGasesMetal.C1.a,SurchauffeurHP1.TwoPhaseFlowPipe.C2.b,SurchauffeurHP1.TwoPhaseFlowPipe.C1.a,SurchauffeurHP1.ExchangerFlueGasesMetal.C2.b,SurchauffeurHP1.ExchangerFlueGasesMetal.C1.a,EconomiseurHP4.TwoPhaseFlowPipe.C2.b,EconomiseurHP4.TwoPhaseFlowPipe.C1.a,EconomiseurHP4.ExchangerFlueGasesMetal.C2.b,EconomiseurHP4.ExchangerFlueGasesMetal.C1.a,EvaporateurHP.TwoPhaseFlowPipe.C2.b,EvaporateurHP.TwoPhaseFlowPipe.C1.a,EvaporateurHP.ExchangerFlueGasesMetal.C2.b,EvaporateurHP.ExchangerFlueGasesMetal.C1.a,VolumeEvapHP.Ce3.a,VolumeEvapHP.Cs.b,VolumeEvapHP.Ce2.a,VolumeEvapHP.Ce1.a,GainChargeHP.C2.b,GainChargeHP.C1.a,vanne_vapeurHP.C2.b,vanne_vapeurHP.C1.a,vanne_alimentationHP.C2.b,vanne_alimentationHP.C1.a,BallonHP.Cs.b,BallonHP.Ce3.a,BallonHP.Ce2.a,BallonHP.Cv.b,BallonHP.Cd.b,BallonHP.Cm.a,BallonHP.Ce1.a,MelangeurPreTMP.Ce3.b,MelangeurPreTMP.Ce2.b,VolumePreTHP.Cs2.a,VolumePreTHP.Cs1.a,VolumeECO_HP2_3.Ce3.b,VolumeECO_HP2_3.Ce2.b,VolumeECO_HP1_2.Ce3.b,VolumeECO_HP1_2.Ce2.b,VolumeAlimMPHP.Ce2.b,VolumeCond1.Ce2.b,VolumeCond1.Ce1.b,MelangeurPostTMP1.Ce3.b,VolumeEvapBP.Ce3.b,VolumeEvapBP.Ce2.b,BallonBP.Ce3.b,BallonBP.Ce2.b,MelangeurHPMP.Cs1.a,VolumeEvapMP.Ce3.b,VolumeEvapMP.Ce2.b,BallonMP.Cs.a,BallonMP.Ce3.b,BallonMP.Ce2.b,VolumeEvapHP.Ce3.b,VolumeEvapHP.Ce2.b,BallonHP.Cs.a,BallonHP.Ce3.b,BallonHP.Ce2.b) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1433): * Single equations (assignments): 1359 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 50 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 7 * Torn equation systems: 15 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 7 systems {1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(4,1,62.5%), (1,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 13 systems {(1,1), (1,1), (1,15), (1,3), (2,11), (1,15), (318,2904), (1,1), (1,1), (1,1), (1,1), (5,14), (1,1)} Notification: Performance of prepare postOptimizeDAE: time 0.03868/15.93, allocations: 9.001 MB / 5.469 GB, free: 158 MB / 1.014 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.01837/15.95, allocations: 3.086 MB / 5.472 GB, free: 155.9 MB / 1.014 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.8167/16.76, allocations: 187.1 MB / 5.655 GB, free: 436 MB / 1.014 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.4351/17.2, allocations: 142.4 MB / 5.794 GB, free: 306.4 MB / 1.014 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 0.0002883/17.2, allocations: 24 kB / 5.794 GB, free: 306.4 MB / 1.014 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.001542/17.2, allocations: 286.9 kB / 5.794 GB, free: 306.1 MB / 1.014 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.9885/18.19, allocations: 253.3 MB / 6.042 GB, free: 390.2 MB / 1.014 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001055/18.19, allocations: 115.5 kB / 6.042 GB, free: 390.2 MB / 1.014 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.08968/18.28, allocations: 16.39 MB / 6.058 GB, free: 390.2 MB / 1.014 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.1308/18.41, allocations: 45.3 MB / 6.102 GB, free: 388.3 MB / 1.014 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0182/18.43, allocations: 1.923 MB / 6.104 GB, free: 388.3 MB / 1.014 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.4528/18.88, allocations: 341 MB / 6.437 GB, free: 86.19 MB / 1.014 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 7.223e-06/18.88, allocations: 11.75 kB / 6.437 GB, free: 86.18 MB / 1.014 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.963/19.85, allocations: 211.4 MB / 6.643 GB, free: 355.4 MB / 1.014 GB Notification: Performance of postOpt removeConstants (simulation): time 0.03538/19.88, allocations: 11.84 MB / 6.655 GB, free: 351.4 MB / 1.014 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.01871/19.9, allocations: 1.192 MB / 6.656 GB, free: 350.5 MB / 1.014 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.06267/19.96, allocations: 6.076 MB / 6.662 GB, free: 349.8 MB / 1.014 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.02213/19.98, allocations: 4.213 MB / 6.666 GB, free: 349.2 MB / 1.014 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.01554/20, allocations: 2.076 MB / 6.668 GB, free: 348.8 MB / 1.014 GB Notification: Performance of sorting global known variables: time 0.01159/20.01, allocations: 6.022 MB / 6.674 GB, free: 346.8 MB / 1.014 GB Notification: Performance of sort global known variables: time 3.1e-07/20.01, allocations: 0.5625 kB / 6.674 GB, free: 346.8 MB / 1.014 GB Notification: Performance of remove unused functions: time 0.06799/20.08, allocations: 15.69 MB / 6.689 GB, free: 345.2 MB / 1.014 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 27 * Number of states: 249 (BallonHP.P,BallonHP.hl,BallonHP.hv,BallonHP.Tp,BallonHP.Vv,VolumeEvapHP.h,EvaporateurHP.ExchangerWall.Tp[1],EvaporateurHP.ExchangerWall.Tp[2],EvaporateurHP.ExchangerWall.Tp[3],EvaporateurHP.TwoPhaseFlowPipe.P[2],EvaporateurHP.TwoPhaseFlowPipe.P[3],EvaporateurHP.TwoPhaseFlowPipe.P[4],EvaporateurHP.TwoPhaseFlowPipe.Q[1],EvaporateurHP.TwoPhaseFlowPipe.Q[2],EvaporateurHP.TwoPhaseFlowPipe.Q[3],EvaporateurHP.TwoPhaseFlowPipe.Q[4],EvaporateurHP.TwoPhaseFlowPipe.h[2],EvaporateurHP.TwoPhaseFlowPipe.h[3],EvaporateurHP.TwoPhaseFlowPipe.h[4],EconomiseurHP4.ExchangerWall.Tp[1],EconomiseurHP4.ExchangerWall.Tp[2],EconomiseurHP4.ExchangerWall.Tp[3],EconomiseurHP4.TwoPhaseFlowPipe.P[2],EconomiseurHP4.TwoPhaseFlowPipe.P[3],EconomiseurHP4.TwoPhaseFlowPipe.P[4],EconomiseurHP4.TwoPhaseFlowPipe.Q[2],EconomiseurHP4.TwoPhaseFlowPipe.Q[3],EconomiseurHP4.TwoPhaseFlowPipe.Q[4],EconomiseurHP4.TwoPhaseFlowPipe.h[2],EconomiseurHP4.TwoPhaseFlowPipe.h[3],EconomiseurHP4.TwoPhaseFlowPipe.h[4],SurchauffeurHP1.ExchangerWall.Tp[1],SurchauffeurHP1.ExchangerWall.Tp[2],SurchauffeurHP1.ExchangerWall.Tp[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[2],SurchauffeurHP1.TwoPhaseFlowPipe.P[3],SurchauffeurHP1.TwoPhaseFlowPipe.P[4],SurchauffeurHP1.TwoPhaseFlowPipe.Q[1],SurchauffeurHP1.TwoPhaseFlowPipe.Q[2],SurchauffeurHP1.TwoPhaseFlowPipe.Q[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[2],SurchauffeurHP1.TwoPhaseFlowPipe.h[3],SurchauffeurHP1.TwoPhaseFlowPipe.h[4],EconomiseurHP3.ExchangerWall.Tp[1],EconomiseurHP3.ExchangerWall.Tp[2],EconomiseurHP3.ExchangerWall.Tp[3],EconomiseurHP3.TwoPhaseFlowPipe.P[2],EconomiseurHP3.TwoPhaseFlowPipe.P[3],EconomiseurHP3.TwoPhaseFlowPipe.P[4],EconomiseurHP3.TwoPhaseFlowPipe.Q[1],EconomiseurHP3.TwoPhaseFlowPipe.Q[2],EconomiseurHP3.TwoPhaseFlowPipe.Q[3],EconomiseurHP3.TwoPhaseFlowPipe.Q[4],EconomiseurHP3.TwoPhaseFlowPipe.h[2],EconomiseurHP3.TwoPhaseFlowPipe.h[3],EconomiseurHP3.TwoPhaseFlowPipe.h[4],EconomiseurHP2.ExchangerWall.Tp[1],EconomiseurHP2.ExchangerWall.Tp[2],EconomiseurHP2.ExchangerWall.Tp[3],EconomiseurHP2.TwoPhaseFlowPipe.P[2],EconomiseurHP2.TwoPhaseFlowPipe.P[3],EconomiseurHP2.TwoPhaseFlowPipe.P[4],EconomiseurHP2.TwoPhaseFlowPipe.Q[1],EconomiseurHP2.TwoPhaseFlowPipe.Q[2],EconomiseurHP2.TwoPhaseFlowPipe.Q[3],EconomiseurHP2.TwoPhaseFlowPipe.Q[4],EconomiseurHP2.TwoPhaseFlowPipe.h[2],EconomiseurHP2.TwoPhaseFlowPipe.h[3],EconomiseurHP2.TwoPhaseFlowPipe.h[4],EconomiseurHP1.ExchangerWall.Tp[1],EconomiseurHP1.ExchangerWall.Tp[2],EconomiseurHP1.ExchangerWall.Tp[3],EconomiseurHP1.TwoPhaseFlowPipe.P[2],EconomiseurHP1.TwoPhaseFlowPipe.P[3],EconomiseurHP1.TwoPhaseFlowPipe.P[4],EconomiseurHP1.TwoPhaseFlowPipe.Q[1],EconomiseurHP1.TwoPhaseFlowPipe.Q[2],EconomiseurHP1.TwoPhaseFlowPipe.Q[3],EconomiseurHP1.TwoPhaseFlowPipe.Q[4],EconomiseurHP1.TwoPhaseFlowPipe.h[2],EconomiseurHP1.TwoPhaseFlowPipe.h[3],EconomiseurHP1.TwoPhaseFlowPipe.h[4],SurchauffeurHP2.ExchangerWall.Tp[1],SurchauffeurHP2.ExchangerWall.Tp[2],SurchauffeurHP2.ExchangerWall.Tp[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[2],SurchauffeurHP2.TwoPhaseFlowPipe.P[3],SurchauffeurHP2.TwoPhaseFlowPipe.P[4],SurchauffeurHP2.TwoPhaseFlowPipe.Q[1],SurchauffeurHP2.TwoPhaseFlowPipe.Q[2],SurchauffeurHP2.TwoPhaseFlowPipe.Q[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[2],SurchauffeurHP2.TwoPhaseFlowPipe.h[3],SurchauffeurHP2.TwoPhaseFlowPipe.h[4],SurchauffeurHP3.ExchangerWall.Tp[1],SurchauffeurHP3.ExchangerWall.Tp[2],SurchauffeurHP3.ExchangerWall.Tp[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[2],SurchauffeurHP3.TwoPhaseFlowPipe.P[3],SurchauffeurHP3.TwoPhaseFlowPipe.P[4],SurchauffeurHP3.TwoPhaseFlowPipe.Q[1],SurchauffeurHP3.TwoPhaseFlowPipe.Q[2],SurchauffeurHP3.TwoPhaseFlowPipe.Q[3],SurchauffeurHP3.TwoPhaseFlowPipe.Q[4],SurchauffeurHP3.TwoPhaseFlowPipe.h[2],SurchauffeurHP3.TwoPhaseFlowPipe.h[3],SurchauffeurHP3.TwoPhaseFlowPipe.h[4],BallonMP.P,BallonMP.hl,BallonMP.hv,BallonMP.Tp,BallonMP.Vv,EvaporateurMP.ExchangerWall.Tp[1],EvaporateurMP.ExchangerWall.Tp[2],EvaporateurMP.ExchangerWall.Tp[3],EvaporateurMP.TwoPhaseFlowPipe.P[2],EvaporateurMP.TwoPhaseFlowPipe.P[3],EvaporateurMP.TwoPhaseFlowPipe.P[4],EvaporateurMP.TwoPhaseFlowPipe.Q[1],EvaporateurMP.TwoPhaseFlowPipe.Q[2],EvaporateurMP.TwoPhaseFlowPipe.Q[3],EvaporateurMP.TwoPhaseFlowPipe.Q[4],EvaporateurMP.TwoPhaseFlowPipe.h[2],EvaporateurMP.TwoPhaseFlowPipe.h[3],EvaporateurMP.TwoPhaseFlowPipe.h[4],VolumeEvapMP.h,EconomiseurMP.ExchangerWall.Tp[1],EconomiseurMP.ExchangerWall.Tp[2],EconomiseurMP.ExchangerWall.Tp[3],EconomiseurMP.TwoPhaseFlowPipe.P[2],EconomiseurMP.TwoPhaseFlowPipe.P[3],EconomiseurMP.TwoPhaseFlowPipe.P[4],EconomiseurMP.TwoPhaseFlowPipe.Q[1],EconomiseurMP.TwoPhaseFlowPipe.Q[2],EconomiseurMP.TwoPhaseFlowPipe.Q[3],EconomiseurMP.TwoPhaseFlowPipe.Q[4],EconomiseurMP.TwoPhaseFlowPipe.h[2],EconomiseurMP.TwoPhaseFlowPipe.h[3],EconomiseurMP.TwoPhaseFlowPipe.h[4],SurchauffeurMP1.ExchangerWall.Tp[1],SurchauffeurMP1.ExchangerWall.Tp[2],SurchauffeurMP1.ExchangerWall.Tp[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[2],SurchauffeurMP1.TwoPhaseFlowPipe.P[3],SurchauffeurMP1.TwoPhaseFlowPipe.P[4],SurchauffeurMP1.TwoPhaseFlowPipe.Q[1],SurchauffeurMP1.TwoPhaseFlowPipe.Q[2],SurchauffeurMP1.TwoPhaseFlowPipe.Q[3],SurchauffeurMP1.TwoPhaseFlowPipe.Q[4],SurchauffeurMP1.TwoPhaseFlowPipe.h[2],SurchauffeurMP1.TwoPhaseFlowPipe.h[3],SurchauffeurMP1.TwoPhaseFlowPipe.h[4],MelangeurHPMP.h,SurchauffeurMP2.ExchangerWall.Tp[1],SurchauffeurMP2.ExchangerWall.Tp[2],SurchauffeurMP2.ExchangerWall.Tp[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[2],SurchauffeurMP2.TwoPhaseFlowPipe.P[3],SurchauffeurMP2.TwoPhaseFlowPipe.P[4],SurchauffeurMP2.TwoPhaseFlowPipe.Q[1],SurchauffeurMP2.TwoPhaseFlowPipe.Q[2],SurchauffeurMP2.TwoPhaseFlowPipe.Q[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[2],SurchauffeurMP2.TwoPhaseFlowPipe.h[3],SurchauffeurMP2.TwoPhaseFlowPipe.h[4],SurchauffeurMP3.ExchangerWall.Tp[1],SurchauffeurMP3.ExchangerWall.Tp[2],SurchauffeurMP3.ExchangerWall.Tp[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[2],SurchauffeurMP3.TwoPhaseFlowPipe.P[3],SurchauffeurMP3.TwoPhaseFlowPipe.P[4],SurchauffeurMP3.TwoPhaseFlowPipe.Q[1],SurchauffeurMP3.TwoPhaseFlowPipe.Q[2],SurchauffeurMP3.TwoPhaseFlowPipe.Q[3],SurchauffeurMP3.TwoPhaseFlowPipe.Q[4],SurchauffeurMP3.TwoPhaseFlowPipe.h[2],SurchauffeurMP3.TwoPhaseFlowPipe.h[3],SurchauffeurMP3.TwoPhaseFlowPipe.h[4],BallonBP.P,BallonBP.hl,BallonBP.hv,BallonBP.Tp,BallonBP.Vv,VolumeEvapBP.h,EvaporateurBP.ExchangerWall.Tp[1],EvaporateurBP.ExchangerWall.Tp[2],EvaporateurBP.ExchangerWall.Tp[3],EvaporateurBP.TwoPhaseFlowPipe.P[2],EvaporateurBP.TwoPhaseFlowPipe.P[3],EvaporateurBP.TwoPhaseFlowPipe.P[4],EvaporateurBP.TwoPhaseFlowPipe.Q[1],EvaporateurBP.TwoPhaseFlowPipe.Q[2],EvaporateurBP.TwoPhaseFlowPipe.Q[3],EvaporateurBP.TwoPhaseFlowPipe.Q[4],EvaporateurBP.TwoPhaseFlowPipe.h[2],EvaporateurBP.TwoPhaseFlowPipe.h[3],EvaporateurBP.TwoPhaseFlowPipe.h[4],SurchauffeurBP.ExchangerWall.Tp[1],SurchauffeurBP.ExchangerWall.Tp[2],SurchauffeurBP.ExchangerWall.Tp[3],SurchauffeurBP.TwoPhaseFlowPipe.P[2],SurchauffeurBP.TwoPhaseFlowPipe.P[3],SurchauffeurBP.TwoPhaseFlowPipe.P[4],SurchauffeurBP.TwoPhaseFlowPipe.Q[1],SurchauffeurBP.TwoPhaseFlowPipe.Q[2],SurchauffeurBP.TwoPhaseFlowPipe.Q[3],SurchauffeurBP.TwoPhaseFlowPipe.Q[4],SurchauffeurBP.TwoPhaseFlowPipe.h[2],SurchauffeurBP.TwoPhaseFlowPipe.h[3],SurchauffeurBP.TwoPhaseFlowPipe.h[4],EconomiseurBP.ExchangerWall.Tp[1],EconomiseurBP.ExchangerWall.Tp[2],EconomiseurBP.ExchangerWall.Tp[3],EconomiseurBP.TwoPhaseFlowPipe.P[2],EconomiseurBP.TwoPhaseFlowPipe.P[3],EconomiseurBP.TwoPhaseFlowPipe.P[4],EconomiseurBP.TwoPhaseFlowPipe.Q[1],EconomiseurBP.TwoPhaseFlowPipe.Q[2],EconomiseurBP.TwoPhaseFlowPipe.Q[3],EconomiseurBP.TwoPhaseFlowPipe.Q[4],EconomiseurBP.TwoPhaseFlowPipe.h[2],EconomiseurBP.TwoPhaseFlowPipe.h[3],EconomiseurBP.TwoPhaseFlowPipe.h[4],MelangeurPostTMP1.h,Condenseur.P,Condenseur.hl,Condenseur.hv,Condenseur.Vv,VolumeCond1.h,VolumeAlimMPHP.h,regulation_Niveau_HP.pIsat.Integrateur1.x,regulation_Niveau_HP.pT1_1.x,regulation_Niveau_MP.pIsat.Integrateur1.x,regulation_Niveau_MP.pT1_1.x,regulation_Niveau_BP.pIsat.Integrateur1.x,regulation_Niveau_BP.pT1_1.x,regulation_Niveau_Condenseur.pIsat.Integrateur1.x,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x,regulation_Niveau_Condenseur.pT1_1.x,regulation_Niveau_Condenseur.pT1_2.x,regulation_Niveau_Condenseur.pT1_3.x,VolumeECO_HP1_2.P,VolumeECO_HP1_2.h,VolumeECO_HP2_3.P,VolumeECO_HP2_3.h,VolumePreTHP.P,VolumePreTHP.h,MelangeurPreTMP.P,MelangeurPreTMP.h) * Number of discrete variables: 9 ($whenCondition1,regulation_Niveau_HP.pIsat.Integrateur1.x0,regulation_Niveau_MP.pIsat.Integrateur1.x0,regulation_Niveau_BP.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat.Integrateur1.x0,regulation_Niveau_Condenseur.pIsat1.Integrateur1.x0,regulation_Niveau_Condenseur.edge.uL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.echelon.yL.signal) * Number of discrete states: 3 (regulation_Niveau_Condenseur.echelon.yL.signal,regulation_Niveau_Condenseur.edge.yL.signal,regulation_Niveau_Condenseur.edge.uL.signal) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (4958): * Single equations (assignments): 4496 * Array equations: 0 * Algorithm blocks: 2 * Record equations: 276 * When equations: 5 * If-equations: 0 * Equation systems (not torn): 7 * Torn equation systems: 172 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 4 systems {(2,100.0%), (2,100.0%), (2,100.0%), (2,100.0%)} * Non-linear Jacobian (size): 3 systems {1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 69 systems {(4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (4,1,62.5%), (1,1,100.0%), (1,2,100.0%), (1,1,100.0%), (1,2,100.0%), (1,2,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%), (1,1,100.0%), (1,1,100.0%), (1,1,100.0%), (2,1,100.0%), (2,1,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 103 systems {(1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,3), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,34), (1,6), (1,6), (1,6), (1,5), (1,1), (1,6), (1,3), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,6), (1,2), (1,2), (1,5), (1,2), (1,2), (1,3), (1,5), (3,16), (1,5), (1,3), (6,14), (1,3), (6,14), (1,3), (1,3), (1,4), (1,4), (1,4), (1,5), (1,3), (8,15), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (6,24), (5,14), (1,1), (1,3)} Notification: Performance of Backend phase and start with SimCode phase: time 0.02942/20.11, allocations: 4.791 MB / 6.694 GB, free: 344.2 MB / 1.014 GB Notification: Performance of simCode: created initialization part: time 0.3545/20.46, allocations: 180.4 MB / 6.87 GB, free: 188.2 MB / 1.014 GB Notification: Performance of simCode: created event and clocks part: time 1.324e-05/20.46, allocations: 0 / 6.87 GB, free: 188.2 MB / 1.014 GB Notification: Performance of simCode: created simulation system equations: time 0.2108/20.68, allocations: 86.42 MB / 6.955 GB, free: 100.9 MB / 1.014 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.1117/20.79, allocations: 15.55 MB / 6.97 GB, free: 86.68 MB / 1.014 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.8002/21.59, allocations: 160.8 MB / 7.127 GB, free: 334 MB / 1.014 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.05122/21.64, allocations: 24.15 MB / 7.15 GB, free: 331.4 MB / 1.014 GB Notification: Performance of simCode: alias equations: time 0.04382/21.68, allocations: 8.688 MB / 7.159 GB, free: 329.9 MB / 1.014 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.02511/21.71, allocations: 3.057 MB / 7.162 GB, free: 329.9 MB / 1.014 GB Notification: Performance of SimCode: time 1.142e-06/21.71, allocations: 0 / 7.162 GB, free: 329.9 MB / 1.014 GB Notification: Performance of Templates: time 4.179/25.89, allocations: 1.574 GB / 8.736 GB, free: 361.8 MB / 1.015 GB make -j1 -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.makefile (rm -f ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.pipe ; mkfifo ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.pipe ; head -c 1048576 < ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.pipe >> ../files/ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.sim & ./ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 -abortSlowSimulation -alarm=480 -lv LOG_STATS > ThermoSysPro_ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50.pipe 2>&1)