Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-08 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./IDEAS_dev_IDEAS.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0323793s reading init.xml | | | | | | 0.00247592s reading info.xml | | | | | | 0.000158347s [ 0.0%] pre-initialization | | | | | | 0.0343006s [ 2.0%] initialization | | | | | | 7.3848e-05s [ 0.0%] steps | | | | | | 0.035651s [ 2.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.586013s [ 34.8%] event-handling | | | | | | 0.0232647s [ 1.4%] overhead | | | | | | 1.00624s [ 59.7%] simulation | | | | | | 1.68571s [100.0%] total | | | | | events | | | | | | 150 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 27286 steps taken | | | | | | 31269 calls of functionODE | | | | | | 3523 evaluations of jacobian | | | | | | 293 error test failures | | | | | | 0 convergence test failures | | | | | | 0.359745s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.