Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_10_Buildings.Fluid.HeatExchangers.RadiantSlabs.Examples.SingleCircuitMultipleCircuitFiniteDifference -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0890475s reading init.xml | | | | | | 0.00775985s reading info.xml | | | | | | 0.00179356s [ 1.1%] pre-initialization | | | | | | 0.00087977s [ 0.5%] initialization | | | | | | 6.9931e-05s [ 0.0%] steps | | | | | | 0.0167392s [ 10.2%] solver (excl. callbacks) | | | | | | 0.00974561s [ 5.9%] creating output-file | | | | | | 0.00129406s [ 0.8%] event-handling | | | | | | 0.0178139s [ 10.9%] overhead | | | | | | 0.115764s [ 70.5%] simulation | | | | | | 0.1641s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 918 steps taken | | | | | | 1131 calls of functionODE | | | | | | 121 evaluations of jacobian | | | | | | 5 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00816322s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.