Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-07 numberOfIntervals=1440 stepSize=60 Regular simulation: ./AixLib_AixLib.Fluid.DistrictHeatingCooling.Demands.Examples.DHCSubstationHeatPumpDirectCooling -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumHeaPri.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/AixLib 1.3.2/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((DHCsubstationHeatingDirectCooling.pumCoo.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0240701s reading init.xml | | | | | | 0.00202265s reading info.xml | | | | | | 0.000114866s [ 0.1%] pre-initialization | | | | | | 0.000463469s [ 0.5%] initialization | | | | | | 1.6652e-05s [ 0.0%] steps | | | | | | 0.00335624s [ 3.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000878553s [ 1.0%] event-handling | | | | | | 0.0193315s [ 21.9%] overhead | | | | | | 0.0641994s [ 72.7%] simulation | | | | | | 0.0883606s [100.0%] total | | | | | events | | | | | | 5 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 561 steps taken | | | | | | 699 calls of functionODE | | | | | | 115 evaluations of jacobian | | | | | | 13 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00460683s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.