Environment - simulationEnvironment: publicData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ privateData = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/ superstructureTables = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/Tables/ superstructureInput = /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/superstructure/RegionInformation/ startTime=0 stopTime=55000 tolerance=1e-06 numberOfIntervals=2500 stepSize=22 Regular simulation: ./TransiEnt_TransiEnt.Producer.Electrical.Conventional.Check.CheckBlackCoal -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.022356s reading init.xml | | | | | | 0.00170755s reading info.xml | | | | | | 0.000173335s [ 0.3%] pre-initialization | | | | | | 0.0430402s [ 68.6%] initialization | | | | | | 2.204e-06s [ 0.0%] steps | | | | | | 0.00116203s [ 1.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.00167384s [ 2.7%] event-handling | | | | | | 0.00411268s [ 6.6%] overhead | | | | | | 0.0125494s [ 20.0%] simulation | | | | | | 0.0627137s [100.0%] total | | | | | events | | | | | | 7 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 405 steps taken | | | | | | 520 calls of functionODE | | | | | | 187 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 0 convergence test failures | | | | | | 4.872e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.