Environment - simulationEnvironment: startTime=1.5552e+07 stopTime=1.56384e+07 tolerance=1e-07 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((hvaCon2.fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((hvaCon2.fan2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 15552069.120000 | | | | ((hvaCon2.fan2.filter.y >= 0.0 and hvaCon2.fan2.filter.y <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= hvaCon2.fan2.filter.y <= 100000.0, has value: -7.17338e-24" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0990942s reading init.xml | | | | | | 0.0067943s reading info.xml | | | | | | 0.00215928s [ 0.1%] pre-initialization | | | | | | 0.148842s [ 6.4%] initialization | | | | | | 7.488e-05s [ 0.0%] steps | | | | | | 0.100377s [ 4.3%] solver (excl. callbacks) | | | | | | 0.0178145s [ 0.8%] creating output-file | | | | | | 0.622908s [ 26.6%] event-handling | | | | | | 0.0473329s [ 2.0%] overhead | | | | | | 1.40083s [ 59.9%] simulation | | | | | | 2.34034s [100.0%] total | | | | | events | | | | | | 361 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 19382 steps taken | | | | | | 24485 calls of functionODE | | | | | | 4516 evaluations of jacobian | | | | | | 509 error test failures | | | | | | 0 convergence test failures | | | | | | 0.736643s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.