Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.MultipleBuildings.TwoIdenticalTwoZoneBuildings -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" LOG_STDOUT | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.29 11:13 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output TwoIdenticalTwoZoneBuildings.bui.inf1.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[2].zon1.duc.m_flow >= 0.0 and bui[2].zon1.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= bui[2].zon1.duc.m_flow <= 100000.0, has value: -2.73576e-14" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[2].zon2.duc.m_flow >= 0.0 and bui[2].zon2.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= bui[2].zon2.duc.m_flow <= 100000.0, has value: -1.36788e-14" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[1].zon1.duc.m_flow >= 0.0 and bui[1].zon1.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= bui[1].zon1.duc.m_flow <= 100000.0, has value: -2.73576e-14" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((bui[1].zon2.duc.m_flow >= 0.0 and bui[1].zon2.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= bui[1].zon2.duc.m_flow <= 100000.0, has value: -1.36788e-14" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0215253s reading init.xml | | | | | | 0.00187428s reading info.xml | | | | | | 0.000492063s [ 0.0%] pre-initialization | | | | | | 7.28122s [ 96.8%] initialization | | | | | | 1.3376e-05s [ 0.0%] steps | | | | | | 0.0129945s [ 0.2%] solver (excl. callbacks) | | | | | | 0.00520001s [ 0.1%] creating output-file | | | | | | 0.0697782s [ 0.9%] event-handling | | | | | | 0.0104822s [ 0.1%] overhead | | | | | | 0.139995s [ 1.9%] simulation | | | | | | 7.52017s [100.0%] total | | | | | events | | | | | | 287 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 4773 steps taken | | | | | | 5628 calls of functionODE | | | | | | 4045 evaluations of jacobian | | | | | | 15 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0359168s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.46sec EnergyPlus Completed Successfully. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf LOG_STDOUT | info | 172200.000 TwoIdenticalTwoZoneBuildings.bui.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. corrupted size vs. prev_size in fastbins