Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_10_Buildings.Examples.ScalableBenchmarks.BuildingVAV.Examples.OneFloor_OneZone -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (fan[1].per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fan[1].per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in OneFloor_OneZone.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fan[1].per.haveWMot_nominal or not (fan[1].per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fan[1].per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in OneFloor_OneZone.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((cooCoi[1].SHR >= 0.0 and cooCoi[1].SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= cooCoi[1].SHR <= 1.0, has value: -5.19989e-30" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fanRet[1].etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fanRet[1].etaHyd, has value: -1.24072e-22" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((fanRet[1].heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fanRet[1].heaDis.etaHyd, has value: -1.1556e-19" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Interfaces.mo:329:5-330:56:writable] | | | | The following assertion has been violated at time 604.800000 | | | | ((eco[1].filter.y >= 0.0 and eco[1].filter.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= eco[1].filter.y <= 1.0, has value: -6.26488e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Blocks/Interfaces.mo:346:5-347:56:writable] | | | | The following assertion has been violated at time 604.800000 | | | | ((eco[1].add.y >= 0.0 and eco[1].add.y <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= eco[1].add.y <= 1.0, has value: 1" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 23103.360000 | | | | ((fanRet[1].eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fanRet[1].eff.yMot, has value: -5.87037e-52" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 151320.960000 | | | | ((fan[1].heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan[1].heaDis.etaHyd, has value: -1.07735e-14" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 151320.960000 | | | | ((fan[1].eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= fan[1].eff.yMot, has value: -2.15471e-21" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.138584s reading init.xml | | | | | | 0.0106215s reading info.xml | | | | | | 0.00397422s [ 0.1%] pre-initialization | | | | | | 0.0340855s [ 0.6%] initialization | | | | | | 7.8508e-05s [ 0.0%] steps | | | | | | 0.229279s [ 3.7%] solver (excl. callbacks) | | | | | | 0.02484s [ 0.4%] creating output-file | | | | | | 1.37433s [ 22.4%] event-handling | | | | | | 0.0515572s [ 0.8%] overhead | | | | | | 4.42419s [ 72.0%] simulation | | | | | | 6.14233s [100.0%] total | | | | | events | | | | | | 281 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 26448 steps taken | | | | | | 37944 calls of functionODE | | | | | | 6468 evaluations of jacobian | | | | | | 1045 error test failures | | | | | | 221 convergence test failures | | | | | | 2.98834s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.