Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_10_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.ElectricHeater -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or mov.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ElectricHeater.mov: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((mov.per.haveWMot_nominal or not (mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or mov.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ElectricHeater.mov: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0105592s reading init.xml | | | | | | 0.000882355s reading info.xml | | | | | | 0.000418986s [ 1.8%] pre-initialization | | | | | | 0.000281448s [ 1.2%] initialization | | | | | | 1.633e-06s [ 0.0%] steps | | | | | | 0.00273042s [ 11.9%] solver (excl. callbacks) | | | | | | 0.00136781s [ 5.9%] creating output-file | | | | | | 0.000666443s [ 2.9%] event-handling | | | | | | 0.00437702s [ 19.0%] overhead | | | | | | 0.0131523s [ 57.2%] simulation | | | | | | 0.0229961s [100.0%] total | | | | | events | | | | | | 6 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2083 steps taken | | | | | | 3179 calls of functionODE | | | | | | 557 evaluations of jacobian | | | | | | 208 error test failures | | | | | | 7 convergence test failures | | | | | | 0.00231907s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.