Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(BuildingSystems.Buildings.Examples.Building1Zone0D,tolerance=1e-06,outputFormat="empty",numberOfIntervals=7200,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D") translateModel(BuildingSystems.Buildings.Examples.Building1Zone0D,tolerance=1e-06,outputFormat="empty",numberOfIntervals=7200,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001048/0.001048, allocations: 108 kB / 15.61 MB, free: 152 kB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001037/0.001037, allocations: 193.7 kB / 16.53 MB, free: 6.664 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.265/1.265, allocations: 222.9 MB / 240.2 MB, free: 4.387 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.002032/0.002032, allocations: 278.8 kB / 290.6 MB, free: 1.996 MB / 238.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.9068/0.9068, allocations: 169.3 MB / 0.4982 GB, free: 13.91 MB / 382.1 MB Notification: Performance of FrontEnd - loaded program: time 0.001578/0.001578, allocations: 98.62 kB / 0.5952 GB, free: 28.04 MB / 430.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1315/0.1331, allocations: 86.98 MB / 0.6802 GB, free: 0.7344 MB / 478.1 MB Notification: Performance of NFInst.instantiate(BuildingSystems.Buildings.Examples.Building1Zone0D): time 0.5318/0.665, allocations: 302.8 MB / 0.9758 GB, free: 8.465 MB / 0.6856 GB Notification: Performance of NFInst.instExpressions: time 0.04157/0.7066, allocations: 27.46 MB / 1.003 GB, free: 12.94 MB / 0.7169 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.008835/0.7154, allocations: 250.8 kB / 1.003 GB, free: 12.69 MB / 0.7169 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:109:3-111:146:writable] Warning: Connector toAmbienceSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:112:3-114:149:writable] Warning: Connector toAmbienceAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToSolids.mo:11:3-13:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ZoneTemplateGeneral.mo:63:3-67:55:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/RadiationDistribution.mo:13:3-15:72:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/AirvolumeGeneral.mo:40:3-41:97:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:52:3-55:54:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:56:3-59:53:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/SolarRadiationTransformers/SolarRadiationTransformerGeneral.mo:25:3-27:116:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:109:3-111:146:writable] Warning: Connector toAmbienceSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/BuildingTemplate.mo:112:3-114:149:writable] Warning: Connector toAmbienceAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToSolids.mo:11:3-13:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ZoneTemplateGeneral.mo:63:3-67:55:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/RadiationDistribution.mo:13:3-15:72:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/SurfaceGeneral.mo:4:3-6:117:writable] Warning: Connector toConstructionPort is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:5:3-7:118:writable] Warning: Connector toAirPort is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfaceToAir.mo:8:3-12:115:writable] Warning: Connector toSurfacesPort is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:9:3-12:23:writable] Warning: Connector toConstructionPorts is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:13:3-16:23:writable] Warning: Connector toSurfacesPorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Surfaces/SurfacesToAir.mo:17:3-19:113:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/AirvolumeGeneral.mo:40:3-41:97:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/Sources/RadiationFixed.mo:4:3-10:117:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:4:3-26:121:writable] Warning: Connector toSurfacePort_1 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToConstructionPortGeneral.mo:12:3-13:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ConstructionGeneral.mo:27:3-50:117:writable] Warning: Connector toSurfacePort_2 is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:4:3-5:117:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Constructions/Windows/RadiationTransmission/RadiationTransmissionSimple.mo:6:3-7:115:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:52:3-55:54:writable] Warning: Connector toAirPorts is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:8:3-9:55:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Interfaces/SurfaceToSurfacesPortGeneral.mo:10:3-11:55:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Ambience.mo:56:3-59:53:writable] Warning: Connector toSurfacePorts is not balanced: The number of potential variables (6) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/SolarRadiationTransformers/SolarRadiationTransformerGeneral.mo:25:3-27:116:writable] Warning: Connector radiationPort is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.006927/0.7224, allocations: 2.638 MB / 1.005 GB, free: 10.06 MB / 0.7169 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/Airvolumes/AirvolumeMixed.mo:70:5-70:12:writable] Warning: Conditional component 'air' is used in a non-connect context. Notification: Performance of NFTyping.typeBindings: time 0.01498/0.7374, allocations: 6.421 MB / 1.012 GB, free: 3.605 MB / 0.7169 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:8:3-10:54:writable] Warning: Connector radiationPort_out is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Buildings/BaseClasses/ShadowingElementGeneral.mo:5:3-7:56:writable] Warning: Connector radiationPort_in is not balanced: The number of potential variables (5) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeClassSections: time 0.008987/0.7464, allocations: 4.432 MB / 1.016 GB, free: 15.19 MB / 0.7325 GB Notification: Performance of NFFlatten.flatten: time 0.0221/0.7685, allocations: 21.34 MB / 1.037 GB, free: 9.781 MB / 0.7481 GB Notification: Performance of NFFlatten.resolveConnections: time 0.3959/1.164, allocations: 26.44 MB / 1.063 GB, free: 17.6 MB / 0.7637 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01618/1.181, allocations: 9.974 MB / 1.072 GB, free: 17.44 MB / 0.7637 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01934/1.2, allocations: 11.23 MB / 1.083 GB, free: 15.83 MB / 0.7637 GB Notification: Performance of NFPackage.collectConstants: time 0.009827/1.21, allocations: 3.067 MB / 1.086 GB, free: 15.83 MB / 0.7637 GB Notification: Performance of NFFlatten.collectFunctions: time 0.0162/1.226, allocations: 5.501 MB / 1.092 GB, free: 15.83 MB / 0.7637 GB Notification: Performance of NFScalarize.scalarize: time 0.01116/1.237, allocations: 6.534 MB / 1.098 GB, free: 15.22 MB / 0.7637 GB Notification: Performance of NFVerifyModel.verify: time 0.01935/1.257, allocations: 11.22 MB / 1.109 GB, free: 12.77 MB / 0.7637 GB Notification: Performance of NFConvertDAE.convert: time 0.03654/1.293, allocations: 35.12 MB / 1.143 GB, free: 8.051 MB / 0.7637 GB Notification: Performance of FrontEnd - DAE generated: time 6.352e-06/1.293, allocations: 3.125 kB / 1.143 GB, free: 8.051 MB / 0.7637 GB Notification: Performance of FrontEnd: time 1.693e-06/1.293, allocations: 1 kB / 1.143 GB, free: 8.051 MB / 0.7637 GB Notification: Performance of Transformations before backend: time 0.00113/1.294, allocations: 0 / 1.143 GB, free: 8.051 MB / 0.7637 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 4400 * Number of variables: 4400 Notification: Performance of Generate backend data structure: time 0.05526/1.35, allocations: 17.93 MB / 1.161 GB, free: 15.2 MB / 0.7794 GB Notification: Performance of prepare preOptimizeDAE: time 4.044e-05/1.35, allocations: 11.88 kB / 1.161 GB, free: 15.2 MB / 0.7794 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02199/1.372, allocations: 3.421 MB / 1.164 GB, free: 13.72 MB / 0.7794 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.02482/1.397, allocations: 9.991 MB / 1.174 GB, free: 7.352 MB / 0.7794 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.001311/1.398, allocations: 1.553 MB / 1.176 GB, free: 6.41 MB / 0.7794 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.007021/1.405, allocations: 1.593 MB / 1.177 GB, free: 5.891 MB / 0.7794 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.07565/1.481, allocations: 25.93 MB / 1.202 GB, free: 12.38 MB / 0.8106 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.000518/1.481, allocations: 20.66 kB / 1.202 GB, free: 12.38 MB / 0.8106 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.006398/1.488, allocations: 0.6719 MB / 1.203 GB, free: 11.71 MB / 0.8106 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.001931/1.49, allocations: 0.8475 MB / 1.204 GB, free: 10.86 MB / 0.8106 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.05687/1.546, allocations: 22.06 MB / 1.225 GB, free: 4.953 MB / 0.8262 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.1409/1.687, allocations: 85.26 MB / 1.309 GB, free: 14.92 MB / 0.92 GB Notification: Performance of preOpt comSubExp (simulation): time 0.01492/1.702, allocations: 6.063 MB / 1.315 GB, free: 8.832 MB / 0.92 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.006317/1.709, allocations: 3.177 MB / 1.318 GB, free: 5.66 MB / 0.92 GB Notification: Performance of preOpt evalFunc (simulation): time 0.002597/1.711, allocations: 2.448 MB / 1.32 GB, free: 2.715 MB / 0.92 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.006852/1.718, allocations: 3.428 MB / 1.324 GB, free: 15.23 MB / 0.9356 GB Notification: Performance of pre-optimization done (n=350): time 6.362e-06/1.718, allocations: 0 / 1.324 GB, free: 15.23 MB / 0.9356 GB Notification: Performance of matching and sorting (n=350): time 0.03683/1.755, allocations: 12.98 MB / 1.336 GB, free: 2.16 MB / 0.9356 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0002286/1.755, allocations: 0.536 MB / 1.337 GB, free: 1.512 MB / 0.9356 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.02159/1.777, allocations: 12.32 MB / 1.349 GB, free: 5.195 MB / 0.9512 GB Notification: Performance of collectPreVariables (initialization): time 0.0009202/1.778, allocations: 93.69 kB / 1.349 GB, free: 5.098 MB / 0.9512 GB Notification: Performance of collectInitialEqns (initialization): time 0.007535/1.785, allocations: 7.4 MB / 1.356 GB, free: 13.66 MB / 0.9669 GB Notification: Performance of collectInitialBindings (initialization): time 0.001781/1.787, allocations: 1.256 MB / 1.357 GB, free: 12.41 MB / 0.9669 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.005015/1.792, allocations: 2.027 MB / 1.359 GB, free: 10.38 MB / 0.9669 GB Notification: Performance of setup shared object (initialization): time 9.243e-05/1.792, allocations: 305.1 kB / 1.36 GB, free: 10.07 MB / 0.9669 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.01003/1.802, allocations: 5.096 MB / 1.365 GB, free: 4.965 MB / 0.9669 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.01172/1.814, allocations: 7.718 MB / 1.372 GB, free: 12.07 MB / 0.9825 GB Notification: Performance of analyzeInitialSystem (initialization): time 6.134/7.948, allocations: 0.9006 GB / 2.273 GB, free: 165.8 MB / 1.014 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 7.922e-05/7.948, allocations: 24 kB / 2.273 GB, free: 165.8 MB / 1.014 GB Notification: Performance of matching and sorting (n=838) (initialization): time 0.03676/7.985, allocations: 15.91 MB / 2.288 GB, free: 154.8 MB / 1.014 GB Notification: Performance of prepare postOptimizeDAE: time 0.0003122/7.986, allocations: 307.4 kB / 2.288 GB, free: 154.5 MB / 1.014 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001147/7.986, allocations: 91.47 kB / 2.289 GB, free: 154.4 MB / 1.014 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.007753/7.993, allocations: 2.53 MB / 2.291 GB, free: 152.3 MB / 1.014 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01335/8.007, allocations: 2.656 MB / 2.294 GB, free: 149.7 MB / 1.014 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02511/8.032, allocations: 30.06 MB / 2.323 GB, free: 119.8 MB / 1.014 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01514/8.047, allocations: 1.391 MB / 2.324 GB, free: 118.9 MB / 1.014 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.003017/8.05, allocations: 0.7223 MB / 2.325 GB, free: 118.1 MB / 1.014 GB Warning: Assuming fixed start value for the following 10 variables: building1.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building1.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building1.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building1.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] building2.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building2.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building2.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building2.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.02226/8.073, allocations: 10.38 MB / 2.335 GB, free: 107.8 MB / 1.014 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.01215/8.085, allocations: 7.677 MB / 2.343 GB, free: 98.88 MB / 1.014 GB Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 6.173/14.26, allocations: 0.9005 GB / 3.243 GB, free: 196.3 MB / 1.014 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 6.697e-05/14.26, allocations: 24 kB / 3.243 GB, free: 196.3 MB / 1.014 GB Notification: Performance of matching and sorting (n=838) (initialization_lambda0): time 0.0337/14.29, allocations: 15.86 MB / 3.259 GB, free: 185.3 MB / 1.014 GB Notification: Performance of prepare postOptimizeDAE: time 0.0001936/14.29, allocations: 308.7 kB / 3.259 GB, free: 185 MB / 1.014 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 9.264e-05/14.29, allocations: 87.98 kB / 3.259 GB, free: 184.9 MB / 1.014 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.007705/14.3, allocations: 2.529 MB / 3.262 GB, free: 182.8 MB / 1.014 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.01202/14.31, allocations: 2.654 MB / 3.264 GB, free: 180.2 MB / 1.014 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.02384/14.34, allocations: 30.04 MB / 3.293 GB, free: 151.2 MB / 1.014 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01189/14.35, allocations: 0.8599 MB / 3.294 GB, free: 150.5 MB / 1.014 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001379/14.35, allocations: 0.7214 MB / 3.295 GB, free: 149.8 MB / 1.014 GB Warning: Assuming fixed start value for the following 10 variables: building1.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building1.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building1.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building1.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building1.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building1.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] building2.zone.airvolume.mH2OLiq:VARIABLE(min = 0.0 start = building2.zone.airvolume.mH2OLiq_start unit = "kg" fixed = true protected = true ) "Liquid water mass" type: Real building2.ambientConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.ambientConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.groundConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.groundConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.innerConstructions.construction.layer[1].T[1]:VARIABLE(min = 0.0 start = building2.innerConstructions.construction.layer[1].T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the numerical node" type: Real [1,1] building2.window[1].heatTransfer.T:VARIABLE(min = 0.0 start = building2.window[1].heatTransfer.T_start unit = "K" fixed = true nominal = 300.0 ) "Temperature of the thermal node" type: Real [1] Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 386 * Number of states: 0 () * Number of discrete variables: 12 (ambience1.radiation[1].outsidePolarCircle,ambience1.radiation[2].outsidePolarCircle,ambience1.weatherDataReader.weatherData.conTim.tNext,$PRE.ambience1.weatherDataReader.weatherData.conTim.tNext,$whenCondition2,ambience2.radiation[1].outsidePolarCircle,ambience2.radiation[2].outsidePolarCircle,ambience2.weatherDataReader.weatherData.conTim.tNext,$PRE.ambience2.weatherDataReader.weatherData.conTim.tNext,$whenCondition1,building1.zone.coolingLoad.I.local_reset,building1.zone.heatingLoad.I.local_reset) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (760): * Single equations (assignments): 734 * Array equations: 0 * Algorithm blocks: 6 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 14 * Torn equation systems: 6 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 14 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 6 systems {(5,20), (1,3), (1,3), (1,3), (5,20), (1,3)} Notification: Performance of prepare postOptimizeDAE: time 0.002125/14.35, allocations: 0.7084 MB / 3.296 GB, free: 149 MB / 1.014 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.002205/14.35, allocations: 0.8466 MB / 3.297 GB, free: 148.5 MB / 1.014 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.02088/14.37, allocations: 9.551 MB / 3.306 GB, free: 138.9 MB / 1.014 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 2.407e-05/14.37, allocations: 47.94 kB / 3.306 GB, free: 138.9 MB / 1.014 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.418e-05/14.37, allocations: 4 kB / 3.306 GB, free: 138.9 MB / 1.014 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.01555/14.39, allocations: 7.841 MB / 3.314 GB, free: 130.9 MB / 1.014 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.0422/14.43, allocations: 25.54 MB / 3.339 GB, free: 105.2 MB / 1.014 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.376e-05/14.43, allocations: 8 kB / 3.339 GB, free: 105.2 MB / 1.014 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.003671/14.44, allocations: 0.7531 MB / 3.339 GB, free: 104.5 MB / 1.014 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.009943/14.45, allocations: 3.042 MB / 3.342 GB, free: 101.4 MB / 1.014 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0003563/14.45, allocations: 119.9 kB / 3.342 GB, free: 101.2 MB / 1.014 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.02233/14.47, allocations: 28.9 MB / 3.371 GB, free: 71.19 MB / 1.014 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 4.378e-06/14.47, allocations: 8 kB / 3.371 GB, free: 71.18 MB / 1.014 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.02529/14.49, allocations: 13.16 MB / 3.383 GB, free: 57.85 MB / 1.014 GB Notification: Performance of postOpt removeConstants (simulation): time 0.004967/14.5, allocations: 2.39 MB / 3.386 GB, free: 55.43 MB / 1.014 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.002582/14.5, allocations: 91.98 kB / 3.386 GB, free: 55.34 MB / 1.014 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.006412/14.51, allocations: 298.2 kB / 3.386 GB, free: 55.05 MB / 1.014 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0007888/14.51, allocations: 295.5 kB / 3.386 GB, free: 54.76 MB / 1.014 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0003713/14.51, allocations: 139.9 kB / 3.387 GB, free: 54.62 MB / 1.014 GB Notification: Performance of sorting global known variables: time 0.0138/14.52, allocations: 8.597 MB / 3.395 GB, free: 46.05 MB / 1.014 GB Notification: Performance of sort global known variables: time 2.91e-07/14.52, allocations: 0 / 3.395 GB, free: 46.05 MB / 1.014 GB Notification: Performance of remove unused functions: time 0.02019/14.54, allocations: 7.522 MB / 3.402 GB, free: 38.52 MB / 1.014 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 20 * Number of states: 18 (building2.zone.airvolume.mH2OLiq,building2.zone.airvolume.air.dynBal.U,building2.zone.airvolume.air.dynBal.m,building2.zone.airvolume.air.dynBal.mXi[1],building2.ambientConstructions.construction.layer[1].T[1],building2.groundConstructions.construction.layer[1].T[1],building2.innerConstructions.construction.layer[1].T[1],building2.window[1].heatTransfer.T,building1.zone.airvolume.mH2OLiq,building1.zone.airvolume.air.dynBal.U,building1.zone.airvolume.air.dynBal.m,building1.zone.airvolume.air.dynBal.mXi[1],building1.zone.heatingLoad.I.y,building1.zone.coolingLoad.I.y,building1.ambientConstructions.construction.layer[1].T[1],building1.groundConstructions.construction.layer[1].T[1],building1.innerConstructions.construction.layer[1].T[1],building1.window[1].heatTransfer.T) * Number of discrete variables: 4 ($whenCondition1,ambience2.weatherDataReader.weatherData.conTim.tNext,$whenCondition2,ambience1.weatherDataReader.weatherData.conTim.tNext) * Number of discrete states: 2 (ambience1.weatherDataReader.weatherData.conTim.tNext,ambience2.weatherDataReader.weatherData.conTim.tNext) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (340): * Single equations (assignments): 318 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 2 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 20 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 20 systems {(5,20), (1,1), (1,1), (1,1), (1,1), (1,1), (1,3), (1,3), (1,1), (1,1), (5,20), (1,1), (1,1), (1,1), (1,1), (1,1), (1,3), (1,3), (1,1), (1,1)} Notification: Performance of Backend phase and start with SimCode phase: time 0.001974/14.54, allocations: 0.7828 MB / 3.403 GB, free: 37.97 MB / 1.014 GB Notification: Performance of simCode: created initialization part: time 0.07895/14.62, allocations: 27.35 MB / 3.43 GB, free: 10.41 MB / 1.014 GB Notification: Performance of simCode: created event and clocks part: time 1.343e-05/14.62, allocations: 8.25 kB / 3.43 GB, free: 10.4 MB / 1.014 GB Notification: Performance of simCode: created simulation system equations: time 0.009637/14.63, allocations: 4.941 MB / 3.435 GB, free: 5.395 MB / 1.014 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01185/14.64, allocations: 2.304 MB / 3.437 GB, free: 3.219 MB / 1.014 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.3455/14.99, allocations: 28.22 MB / 3.464 GB, free: 447.4 MB / 1.014 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.0174/15.01, allocations: 9.784 MB / 3.474 GB, free: 446.4 MB / 1.014 GB Notification: Performance of simCode: alias equations: time 0.02027/15.03, allocations: 5.035 MB / 3.479 GB, free: 445.7 MB / 1.014 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.003401/15.03, allocations: 0.773 MB / 3.48 GB, free: 445.6 MB / 1.014 GB Notification: Performance of SimCode: time 7.51e-07/15.03, allocations: 0 / 3.48 GB, free: 445.6 MB / 1.014 GB Notification: Performance of Templates: time 0.2465/15.28, allocations: 188.9 MB / 3.664 GB, free: 302.3 MB / 1.014 GB make -j1 -f BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.makefile (rm -f BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe ; mkfifo BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe ; head -c 1048576 < BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe >> ../files/BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.sim & ./BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D -abortSlowSimulation -alarm=480 -lv LOG_STATS > BuildingSystems_BuildingSystems.Buildings.Examples.Building1Zone0D.pipe 2>&1)