Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.FixedResistances.Validation.PlugFlowPipes.TransportWaterAir -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STDOUT | warning | Removed more then one event from spatialDistribution. Step size to big! LOG_STDOUT | warning | time: 0.000000, spatialDistribution index: 5, number of events: 2 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0128715s reading init.xml | | | | | | 0.00121969s reading info.xml | | | | | | 0.000111129s [ 0.2%] pre-initialization | | | | | | 0.000350838s [ 0.5%] initialization | | | | | | 8.727e-06s [ 0.0%] steps | | | | | | 0.0024549s [ 3.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0125194s [ 17.5%] event-handling | | | | | | 0.00940328s [ 13.1%] overhead | | | | | | 0.0467681s [ 65.3%] simulation | | | | | | 0.0716164s [100.0%] total | | | | | events | | | | | | 7 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 858 steps taken | | | | | | 1498 calls of functionODE | | | | | | 359 evaluations of jacobian | | | | | | 129 error test failures | | | | | | 9 convergence test failures | | | | | | 0.00591144s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.