/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary_fmu --startTime=0 --stopTime=21600 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary/temp_Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary_fmu/model-qe3fbxyk/temp/0001_Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_terminated state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.IntegratedPrimarySecondary/temp_Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary_fmu/model-qe3fbxyk/temp/0001_Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary (logStatusError): fmi2SetContinuousStates: Illegal model exchange call sequence. fmi2SetContinuousStates is not allowed in model_state_error state. error: [setContinuousStates] fmi2_setContinuousStates failed for FMU "model.root.Buildings_8_Buildings_Applications_DataCenters_ChillerCooled_Equipment_Validation_IntegratedPrimarySecondary"