python3 -m fmpy simulate --output-file TransiEnt_TransiEnt.Components.Heat.Check.TestPipeGasAdvanced_res.csv --start-time 0 --stop-time 1200 --timeout 50 --relative-tolerance 1e-05 --interface-type ModelExchange --solver CVode --output-interval 0.48 TransiEnt_TransiEnt_Components_Heat_Check_TestPipeGasAdvanced.fmu LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables//ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/ambient/UndergroundTemperature_Duesseldorf_1m_2017.txt" LOG_STDOUT | info | >> Looking for file: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master//Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | >> Calling File: /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt LOG_STDOUT | info | ... loading "default" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Tables/electricity/ElectricityPrices_DayAhead_EPEX_Spot_2011.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/HeatTransfer_L4.mo:27:3-27:147:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe.airVolume.heatTransferInner.A_heat[3] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe.airVolume.heatTransferInner.A_heat[3], has value: -1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/HeatTransfer_L4.mo:27:3-27:147:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe.airVolume.heatTransferInner.A_heat[2] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe.airVolume.heatTransferInner.A_heat[2], has value: -1" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Basics/ControlVolumes/Fundamentals/HeatTransport/Generic_HT/HeatTransfer_L4.mo:27:3-27:147:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pipe.airVolume.heatTransferInner.A_heat[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= pipe.airVolume.heatTransferInner.A_heat[1], has value: -1" LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 LOG_ASSERT | debug | Model error: Argument of sqrt(pipe.airVolume.pressureLoss.zeta[3] * pipe.airVolume.pressureLoss.rho[3]) was -1.24912e-05 should be >= 0 LOG_ASSERT | debug | Solving non-linear system 370 failed at time=0. | | | | For more information please use -lv LOG_NLS. LOG_ASSERT | error | Failed to solve the initialization problem with global homotopy with equidistant step size. LOG_ASSERT | debug | Unable to solve initialization problem. Traceback (most recent call last): File "/usr/lib/python3.10/runpy.py", line 196, in _run_module_as_main return _run_code(code, main_globals, None, File "/usr/lib/python3.10/runpy.py", line 86, in _run_code exec(code, run_globals) File "/usr/local/lib/python3.10/dist-packages/fmpy/__main__.py", line 4, in main() File "/usr/local/lib/python3.10/dist-packages/fmpy/command_line.py", line 167, in main result = simulate_fmu(args.fmu_filename, File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 759, in simulate_fmu result = simulateME(model_description, fmu, start_time, stop_time, solver, step_size, relative_tolerance, start_values, apply_default_start_values, input, output, output_interval, record_events, timeout, step_finished, validate, set_stop_time) File "/usr/local/lib/python3.10/dist-packages/fmpy/simulation.py", line 933, in simulateME fmu.exitInitializationMode() File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 280, in exitInitializationMode return self.fmi2ExitInitializationMode(self.component) File "/usr/local/lib/python3.10/dist-packages/fmpy/fmi2.py", line 215, in w raise FMICallException(function=fname, status=res) fmpy.fmi1.FMICallException: fmi2ExitInitializationMode failed with status 3 (error).