Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo) Running command: translateModel(TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=28800,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter") translateModel(TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter,tolerance=1e-06,outputFormat="empty",numberOfIntervals=28800,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo): time 2.207/2.207, allocations: 389.5 MB / 409 MB, free: 12.76 MB / 318.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0005195/0.0005194, allocations: 31.89 kB / 0.489 GB, free: 4.914 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 0.6819/0.6819, allocations: 127.2 MB / 0.7027 GB, free: 5.664 MB / 0.4981 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo): time 0.08718/0.08718, allocations: 22.38 MB / 0.8394 GB, free: 16.57 MB / 0.5294 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01038/0.01038, allocations: 0.8848 MB / 0.9614 GB, free: 3.531 MB / 0.6388 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.249/0.249, allocations: 45.02 MB / 1.127 GB, free: 97.98 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.08193/0.08193, allocations: 13.54 MB / 1.27 GB, free: 93.66 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001515/0.001515, allocations: 108.7 kB / 1.403 GB, free: 7.312 MB / 0.7013 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001344/0.001344, allocations: 188.9 kB / 1.536 GB, free: 222.9 MB / 0.8263 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.56/1.56, allocations: 222.9 MB / 1.886 GB, free: 91.88 MB / 0.8888 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0005776/0.0005774, allocations: 31.94 kB / 2.068 GB, free: 15.27 MB / 0.92 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0006434/0.0006434, allocations: 31.92 kB / 2.249 GB, free: 5.473 MB / 1.092 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.066/1.066, allocations: 220.7 MB / 2.646 GB, free: 132.2 MB / 1.123 GB Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.1 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, "1.8.1") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.2 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.004991/0.004991, allocations: 307.2 kB / 2.893 GB, free: 111.9 MB / 1.123 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4545/0.4595, allocations: 229.5 MB / 3.117 GB, free: 11.23 MB / 1.233 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/Power2Heat/ElectricBoiler/ElectricBoiler.mo:45:3-45:50:writable] Warning: An inner declaration for outer component modelStatistics could not be found and was automatically generated. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/Power2Heat/ElectricBoiler/ElectricBoiler.mo:45:3-45:50:writable] Notification: The diagnostics message for the missing inner is: Your model is using an outer "modelStatistics" but it does not contain an inner "modelStatistics" component. Drag model TransiEnt.ModelStatistics into your model to make it work. Notification: Performance of NFInst.instantiate(TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter): time 0.04953/0.5091, allocations: 38.13 MB / 3.154 GB, free: 5.172 MB / 1.264 GB Notification: Performance of NFInst.instExpressions: time 0.0269/0.536, allocations: 15.46 MB / 3.17 GB, free: 5.668 MB / 1.28 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.004263/0.5403, allocations: 67.69 kB / 3.17 GB, free: 5.602 MB / 1.28 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectHeatingPower.mo:68:3-68:143:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.007192/0.5475, allocations: 1.966 MB / 3.172 GB, free: 3.625 MB / 1.28 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Producer/Heat/Power2Heat/ElectricBoiler/ElectricBoiler.mo:113:34-113:90:writable] Warning: Conditional component 'heatFlowBoundary' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Notification: Performance of NFTyping.typeBindings: time 0.008391/0.5559, allocations: 2.039 MB / 3.174 GB, free: 1.609 MB / 1.28 GB Warning: Allowing usage of enumeration expression: PtH.collectElectricPower.typeOfResource as Integer: CAST(Integer, PtH.collectElectricPower.typeOfResource). This is non-standard Modelica, use Integer(PtH.collectElectricPower.typeOfResource) instead! Warning: Allowing usage of enumeration expression: PtH.collectHeatingPower.typeOfResource as Integer: CAST(Integer, PtH.collectHeatingPower.typeOfResource). This is non-standard Modelica, use Integer(PtH.collectHeatingPower.typeOfResource) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:524:13-528:28:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.specificEnthalpy_pTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.specificEnthalpy_pTxi'. Notification: Performance of NFTyping.typeClassSections: time 0.006092/0.562, allocations: 1.975 MB / 3.175 GB, free: 15.64 MB / 1.295 GB Notification: Performance of NFFlatten.flatten: time 0.01038/0.5724, allocations: 5.499 MB / 3.181 GB, free: 10.12 MB / 1.295 GB Notification: Performance of NFFlatten.resolveConnections: time 0.005272/0.5777, allocations: 2.69 MB / 3.183 GB, free: 7.375 MB / 1.295 GB Notification: Performance of NFEvalConstants.evaluate: time 0.005051/0.5828, allocations: 2.471 MB / 3.186 GB, free: 4.895 MB / 1.295 GB Notification: Performance of NFSimplifyModel.simplify: time 0.004704/0.5875, allocations: 2.549 MB / 3.188 GB, free: 2.336 MB / 1.295 GB Notification: Performance of NFPackage.collectConstants: time 0.001977/0.5896, allocations: 452 kB / 3.189 GB, free: 1.895 MB / 1.295 GB Notification: Performance of NFFlatten.collectFunctions: time 0.003761/0.5933, allocations: 1.104 MB / 3.19 GB, free: 0.7891 MB / 1.295 GB Notification: Performance of NFScalarize.scalarize: time 0.002541/0.5959, allocations: 1.666 MB / 3.191 GB, free: 15.12 MB / 1.311 GB Notification: Performance of NFVerifyModel.verify: time 0.005374/0.6013, allocations: 2.758 MB / 3.194 GB, free: 12.34 MB / 1.311 GB Notification: Performance of NFConvertDAE.convert: time 0.01167/0.613, allocations: 7.557 MB / 3.202 GB, free: 4.762 MB / 1.311 GB Notification: Performance of FrontEnd - DAE generated: time 6.732e-06/0.613, allocations: 3.938 kB / 3.202 GB, free: 4.758 MB / 1.311 GB Notification: Performance of FrontEnd: time 1.493e-06/0.613, allocations: 4 kB / 3.202 GB, free: 4.754 MB / 1.311 GB Notification: Performance of Transformations before backend: time 0.0003266/0.6134, allocations: 0 / 3.202 GB, free: 4.754 MB / 1.311 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 803 * Number of variables: 803 Notification: Performance of Generate backend data structure: time 0.01544/0.6288, allocations: 6.38 MB / 3.208 GB, free: 14.28 MB / 1.326 GB Notification: Performance of prepare preOptimizeDAE: time 4.82e-05/0.6289, allocations: 9.516 kB / 3.208 GB, free: 14.27 MB / 1.326 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.001741/0.6306, allocations: 0.692 MB / 3.208 GB, free: 13.57 MB / 1.326 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.009099/0.6398, allocations: 4.973 MB / 3.213 GB, free: 8.535 MB / 1.326 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0003336/0.6401, allocations: 353.7 kB / 3.214 GB, free: 8.156 MB / 1.326 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0003994/0.6405, allocations: 256 kB / 3.214 GB, free: 7.906 MB / 1.326 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.005929/0.6465, allocations: 4.11 MB / 3.218 GB, free: 3.152 MB / 1.326 GB Notification: Performance of preOpt findStateOrder (simulation): time 6.681e-05/0.6466, allocations: 27.75 kB / 3.218 GB, free: 3.125 MB / 1.326 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0002514/0.6468, allocations: 124 kB / 3.218 GB, free: 3.004 MB / 1.326 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 6.463e-05/0.6469, allocations: 83.94 kB / 3.218 GB, free: 2.922 MB / 1.326 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.004827/0.6517, allocations: 2.812 MB / 3.221 GB, free: 104 kB / 1.326 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.02482/0.6766, allocations: 23.59 MB / 3.244 GB, free: 7.344 MB / 1.358 GB Notification: Performance of preOpt comSubExp (simulation): time 0.002695/0.6793, allocations: 1.16 MB / 3.245 GB, free: 6.074 MB / 1.358 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.001113/0.6805, allocations: 0.6003 MB / 3.246 GB, free: 5.434 MB / 1.358 GB Notification: Performance of preOpt evalFunc (simulation): time 0.005629/0.6861, allocations: 4.037 MB / 3.25 GB, free: 1.172 MB / 1.358 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.001397/0.6875, allocations: 0.8495 MB / 3.25 GB, free: 248 kB / 1.358 GB Notification: Performance of preOpt simplifyInStream (simulation): time 0.001812/0.6894, allocations: 392.7 kB / 3.251 GB, free: 15.85 MB / 1.373 GB Notification: Performance of pre-optimization done (n=216): time 6.322e-06/0.6894, allocations: 0 / 3.251 GB, free: 15.85 MB / 1.373 GB Notification: Performance of matching and sorting (n=216): time 0.004538/0.6939, allocations: 2.192 MB / 3.253 GB, free: 13.66 MB / 1.373 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0003608/0.6943, allocations: 0.6598 MB / 3.254 GB, free: 12.84 MB / 1.373 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.00911/0.7034, allocations: 5.569 MB / 3.259 GB, free: 7.289 MB / 1.373 GB Notification: Performance of collectPreVariables (initialization): time 0.000324/0.7038, allocations: 41.7 kB / 3.259 GB, free: 7.242 MB / 1.373 GB Notification: Performance of collectInitialEqns (initialization): time 0.002335/0.7061, allocations: 2.778 MB / 3.262 GB, free: 4.434 MB / 1.373 GB Notification: Performance of collectInitialBindings (initialization): time 0.0009515/0.7071, allocations: 0.7395 MB / 3.263 GB, free: 3.684 MB / 1.373 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.001233/0.7083, allocations: 0.8993 MB / 3.263 GB, free: 2.77 MB / 1.373 GB Notification: Performance of setup shared object (initialization): time 0.0001137/0.7085, allocations: 309.1 kB / 3.264 GB, free: 2.465 MB / 1.373 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.001873/0.7103, allocations: 1.081 MB / 3.265 GB, free: 1.363 MB / 1.373 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.00336/0.7137, allocations: 3.292 MB / 3.268 GB, free: 12.95 MB / 1.389 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.m_CDE_produced = $START.PtH.collectCosts_HeatProducer.m_CDE_produced (0.0 = $START.PtH.collectCosts_HeatProducer.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.other_demand = $START.PtH.collectCosts_HeatProducer.other_demand (0.0 = $START.PtH.collectCosts_HeatProducer.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.other_revenue = $START.PtH.collectCosts_HeatProducer.other_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.H_demand = $START.PtH.collectCosts_HeatProducer.H_demand (0.0 = $START.PtH.collectCosts_HeatProducer.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.H_revenue = $START.PtH.collectCosts_HeatProducer.H_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.Q_demand = $START.PtH.collectCosts_HeatProducer.Q_demand (0.0 = $START.PtH.collectCosts_HeatProducer.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.Q_revenue = $START.PtH.collectCosts_HeatProducer.Q_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.W_el_demand = $START.PtH.collectCosts_HeatProducer.W_el_demand (0.0 = $START.PtH.collectCosts_HeatProducer.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.W_el_revenue = $START.PtH.collectCosts_HeatProducer.W_el_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectElectricPower.E = $START.PtH.collectElectricPower.E (0.0 = $START.PtH.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectHeatingPower.E = $START.PtH.collectHeatingPower.E (0.0 = $START.PtH.collectHeatingPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.m_CDE_consumed = $START.PtH.collectCosts_HeatProducer.m_CDE_consumed (0.0 = $START.PtH.collectCosts_HeatProducer.m_CDE_consumed) Notification: Performance of analyzeInitialSystem (initialization): time 0.0108/0.7245, allocations: 11.49 MB / 3.279 GB, free: 15.01 MB / 1.405 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 9.341e-05/0.7246, allocations: 20 kB / 3.279 GB, free: 14.99 MB / 1.405 GB Notification: Performance of matching and sorting (n=568) (initialization): time 0.00866/0.7333, allocations: 4.136 MB / 3.283 GB, free: 10.84 MB / 1.405 GB Notification: Performance of prepare postOptimizeDAE: time 6.74e-05/0.7334, allocations: 45.34 kB / 3.283 GB, free: 10.8 MB / 1.405 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.0001877/0.7336, allocations: 132.8 kB / 3.283 GB, free: 10.67 MB / 1.405 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0001087/0.7337, allocations: 104 kB / 3.283 GB, free: 10.57 MB / 1.405 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002088/0.7358, allocations: 0.7914 MB / 3.284 GB, free: 9.773 MB / 1.405 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0001168/0.736, allocations: 151.4 kB / 3.284 GB, free: 9.625 MB / 1.405 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.003229/0.7392, allocations: 167.8 kB / 3.285 GB, free: 9.461 MB / 1.405 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0003418/0.7396, allocations: 236 kB / 3.285 GB, free: 9.23 MB / 1.405 GB Warning: The initial conditions are over specified. The following 74 initial equations are redundant, so they are removed from the initialization system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] PtH.collectCosts_HeatProducer.m_CDE_produced = $START.PtH.collectCosts_HeatProducer.m_CDE_produced PtH.collectCosts_HeatProducer.other_demand = $START.PtH.collectCosts_HeatProducer.other_demand PtH.collectCosts_HeatProducer.other_revenue = $START.PtH.collectCosts_HeatProducer.other_revenue PtH.collectCosts_HeatProducer.H_demand = $START.PtH.collectCosts_HeatProducer.H_demand PtH.collectCosts_HeatProducer.H_revenue = $START.PtH.collectCosts_HeatProducer.H_revenue PtH.collectCosts_HeatProducer.Q_demand = $START.PtH.collectCosts_HeatProducer.Q_demand PtH.collectCosts_HeatProducer.Q_revenue = $START.PtH.collectCosts_HeatProducer.Q_revenue PtH.collectCosts_HeatProducer.W_el_demand = $START.PtH.collectCosts_HeatProducer.W_el_demand PtH.collectCosts_HeatProducer.W_el_revenue = $START.PtH.collectCosts_HeatProducer.W_el_revenue modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg PtH.collectElectricPower.E = $START.PtH.collectElectricPower.E PtH.collectHeatingPower.E = $START.PtH.collectHeatingPower.E PtH.collectCosts_HeatProducer.m_CDE_consumed = $START.PtH.collectCosts_HeatProducer.m_CDE_consumed. Notification: Performance of preBalanceInitialSystem (initialization_lambda0): time 0.004686/0.7443, allocations: 2.814 MB / 3.288 GB, free: 6.32 MB / 1.405 GB Notification: Performance of partitionIndependentBlocks (initialization_lambda0): time 0.003219/0.7475, allocations: 3.288 MB / 3.291 GB, free: 1.914 MB / 1.405 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.m_CDE_produced = $START.PtH.collectCosts_HeatProducer.m_CDE_produced (0.0 = $START.PtH.collectCosts_HeatProducer.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.other_demand = $START.PtH.collectCosts_HeatProducer.other_demand (0.0 = $START.PtH.collectCosts_HeatProducer.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.other_revenue = $START.PtH.collectCosts_HeatProducer.other_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.H_demand = $START.PtH.collectCosts_HeatProducer.H_demand (0.0 = $START.PtH.collectCosts_HeatProducer.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.H_revenue = $START.PtH.collectCosts_HeatProducer.H_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.Q_demand = $START.PtH.collectCosts_HeatProducer.Q_demand (0.0 = $START.PtH.collectCosts_HeatProducer.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.Q_revenue = $START.PtH.collectCosts_HeatProducer.Q_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.W_el_demand = $START.PtH.collectCosts_HeatProducer.W_el_demand (0.0 = $START.PtH.collectCosts_HeatProducer.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.W_el_revenue = $START.PtH.collectCosts_HeatProducer.W_el_revenue (0.0 = $START.PtH.collectCosts_HeatProducer.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectElectricPower.E = $START.PtH.collectElectricPower.E (0.0 = $START.PtH.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectHeatingPower.E = $START.PtH.collectHeatingPower.E (0.0 = $START.PtH.collectHeatingPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: PtH.collectCosts_HeatProducer.m_CDE_consumed = $START.PtH.collectCosts_HeatProducer.m_CDE_consumed (0.0 = $START.PtH.collectCosts_HeatProducer.m_CDE_consumed) Notification: Performance of analyzeInitialSystem (initialization_lambda0): time 1.405/2.152, allocations: 11.43 MB / 3.302 GB, free: 157.3 MB / 1.405 GB Notification: Performance of solveInitialSystemEqSystem (initialization_lambda0): time 0.0001023/2.153, allocations: 24.12 kB / 3.302 GB, free: 157.3 MB / 1.405 GB Notification: Performance of matching and sorting (n=568) (initialization_lambda0): time 0.008497/2.161, allocations: 4.113 MB / 3.306 GB, free: 156.8 MB / 1.405 GB Notification: Performance of prepare postOptimizeDAE: time 6.335e-05/2.161, allocations: 41.03 kB / 3.306 GB, free: 156.8 MB / 1.405 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.000215/2.161, allocations: 136 kB / 3.306 GB, free: 156.8 MB / 1.405 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.0001659/2.162, allocations: 107 kB / 3.306 GB, free: 156.8 MB / 1.405 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.002187/2.164, allocations: 0.782 MB / 3.307 GB, free: 156.8 MB / 1.405 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.000161/2.164, allocations: 154.5 kB / 3.307 GB, free: 156.7 MB / 1.405 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.002644/2.167, allocations: 159.1 kB / 3.307 GB, free: 156.7 MB / 1.405 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0003414/2.167, allocations: 234.4 kB / 3.308 GB, free: 156.7 MB / 1.405 GB Warning: The initial conditions are over specified. The following 74 initial equations are redundant, so they are removed from the initialization_lambda0 system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] PtH.collectCosts_HeatProducer.m_CDE_produced = $START.PtH.collectCosts_HeatProducer.m_CDE_produced PtH.collectCosts_HeatProducer.other_demand = $START.PtH.collectCosts_HeatProducer.other_demand PtH.collectCosts_HeatProducer.other_revenue = $START.PtH.collectCosts_HeatProducer.other_revenue PtH.collectCosts_HeatProducer.H_demand = $START.PtH.collectCosts_HeatProducer.H_demand PtH.collectCosts_HeatProducer.H_revenue = $START.PtH.collectCosts_HeatProducer.H_revenue PtH.collectCosts_HeatProducer.Q_demand = $START.PtH.collectCosts_HeatProducer.Q_demand PtH.collectCosts_HeatProducer.Q_revenue = $START.PtH.collectCosts_HeatProducer.Q_revenue PtH.collectCosts_HeatProducer.W_el_demand = $START.PtH.collectCosts_HeatProducer.W_el_demand PtH.collectCosts_HeatProducer.W_el_revenue = $START.PtH.collectCosts_HeatProducer.W_el_revenue modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg PtH.collectElectricPower.E = $START.PtH.collectElectricPower.E PtH.collectHeatingPower.E = $START.PtH.collectHeatingPower.E PtH.collectCosts_HeatProducer.m_CDE_consumed = $START.PtH.collectCosts_HeatProducer.m_CDE_consumed. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 355 * Number of states: 0 () * Number of discrete variables: 11 ($PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,ptH_limiter.OpMode) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (442): * Single equations (assignments): 424 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 18 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Performance of prepare postOptimizeDAE: time 0.001268/2.168, allocations: 1.09 MB / 3.309 GB, free: 156.1 MB / 1.405 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.0009023/2.169, allocations: 0.5549 MB / 3.309 GB, free: 156.1 MB / 1.405 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.002908/2.172, allocations: 1.253 MB / 3.31 GB, free: 156 MB / 1.405 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 2.939e-05/2.172, allocations: 19.62 kB / 3.31 GB, free: 156 MB / 1.405 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.574e-05/2.172, allocations: 8.219 kB / 3.31 GB, free: 156 MB / 1.405 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 2.313e-05/2.172, allocations: 12.05 kB / 3.31 GB, free: 156 MB / 1.405 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.004836/2.177, allocations: 2.856 MB / 3.313 GB, free: 154.9 MB / 1.405 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.0001222/2.177, allocations: 59.69 kB / 3.313 GB, free: 154.9 MB / 1.405 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.000572/2.178, allocations: 135.1 kB / 3.313 GB, free: 154.9 MB / 1.405 GB Notification: Performance of postOpt tearingSystem (simulation): time 1.584e-05/2.178, allocations: 9.297 kB / 3.313 GB, free: 154.9 MB / 1.405 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 8.271e-05/2.178, allocations: 37.86 kB / 3.313 GB, free: 154.8 MB / 1.405 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 1.402e-05/2.178, allocations: 14.09 kB / 3.313 GB, free: 154.8 MB / 1.405 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 9.197e-06/2.178, allocations: 12.33 kB / 3.313 GB, free: 154.8 MB / 1.405 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.003184/2.181, allocations: 1.88 MB / 3.315 GB, free: 153.9 MB / 1.405 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001552/2.183, allocations: 0.9854 MB / 3.316 GB, free: 153.2 MB / 1.405 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0004096/2.183, allocations: 25.14 kB / 3.316 GB, free: 153.2 MB / 1.405 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.0009171/2.184, allocations: 36.39 kB / 3.316 GB, free: 153.2 MB / 1.405 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0002023/2.184, allocations: 93.33 kB / 3.316 GB, free: 153.2 MB / 1.405 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0001035/2.184, allocations: 49.45 kB / 3.316 GB, free: 153.2 MB / 1.405 GB Notification: Performance of sorting global known variables: time 0.006638/2.191, allocations: 3.659 MB / 3.32 GB, free: 152 MB / 1.405 GB Notification: Performance of sort global known variables: time 4.5e-07/2.191, allocations: 0 / 3.32 GB, free: 152 MB / 1.405 GB Notification: Performance of remove unused functions: time 0.007001/2.198, allocations: 1.681 MB / 3.322 GB, free: 151.7 MB / 1.405 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 23 * Number of states: 0 () * Number of discrete variables: 7 (ptH_limiter.OpMode,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled) * Number of discrete states: 4 (simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (91): * Single equations (assignments): 69 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 18 * When equations: 4 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.002619/2.201, allocations: 1.184 MB / 3.323 GB, free: 151.5 MB / 1.405 GB Notification: Performance of simCode: created initialization part: time 0.01082/2.211, allocations: 5.559 MB / 3.328 GB, free: 148.8 MB / 1.405 GB Notification: Performance of simCode: created event and clocks part: time 1.365e-05/2.211, allocations: 0 / 3.328 GB, free: 148.8 MB / 1.405 GB Notification: Performance of simCode: created simulation system equations: time 0.001535/2.213, allocations: 1.155 MB / 3.329 GB, free: 147.9 MB / 1.405 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.003562/2.217, allocations: 0.6901 MB / 3.33 GB, free: 147.6 MB / 1.405 GB Warning: The hideResult annotation could not be evaluated, probably due to missing annotation(Evaluate=true). It is removed. Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.01322/2.23, allocations: 8.575 MB / 3.338 GB, free: 143.6 MB / 1.405 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.002645/2.232, allocations: 2.843 MB / 3.341 GB, free: 142.6 MB / 1.405 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.001226/2.234, allocations: 406 kB / 3.342 GB, free: 142.5 MB / 1.405 GB Notification: Performance of SimCode: time 6.21e-07/2.234, allocations: 0 / 3.342 GB, free: 142.5 MB / 1.405 GB Notification: Performance of Templates: time 0.09658/2.33, allocations: 56.5 MB / 3.397 GB, free: 120.6 MB / 1.405 GB make -j1 -f TransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter.makefile make -j1 -f TransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiter.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterCalcHelperMain.o OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterCalcHelperMain.cpp In file included from OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterCalcHelperMain.cpp:28: ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:631:25: error: no matching function for call to 'TILMedia_createExternalObject' externalObject__ext = TILMedia_createExternalObject(objectType_.c_str(), mediumName_.c_str(), flags__ext, ConstArray(xi_).getData(), nc__ext, condensingIndex__ext, instanceName_.c_str()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:43:7: note: candidate function not viable: 4th argument ('const double *') would lose const qualifier void* TILMedia_createExternalObject(const char* objectType, const char* mixtureName, int flags, double* xi, int _nc, int condensingIndex, const char* instanceName) { ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:676:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_density_pTxi' d__ext = TILMedia_VLEFluidObjectFunctions_density_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:17:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_density_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:702:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_density_phxi' d__ext = TILMedia_VLEFluid_Cached_density_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:16:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_density_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:728:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:15:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:754:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi' s__ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:14:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:780:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi' s__ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:13:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:806:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_temperature_phxi' T__ext = TILMedia_VLEFluidObjectFunctions_temperature_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:12:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_temperature_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:881:3: error: no matching function for call to 'TILMedia_VLEFluid_VLEProperties_phxi' TILMedia_VLEFluid_VLEProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &d_l__ext, &h_l__ext, &p_l__ext, &s_l__ext, &T_l__ext, xi_l_.getData(), &d_v__ext, &h_v__ext, &p_v__ext, &s_v__ext, &T_v__ext, xi_v_.getData()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:10:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_VLEProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:978:3: error: no matching function for call to 'TILMedia_VLEFluid_additionalProperties_phxi' TILMedia_VLEFluid_additionalProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &x__ext, &cp__ext, &cv__ext, &beta__ext, &kappa__ext, &drhodp__ext, &drhodh__ext, drhodxi_.getData(), &a__ext, &gamma__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:9:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_additionalProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:1045:3: error: no matching function for call to 'TILMedia_VLEFluid_cricondenbar_xi' TILMedia_VLEFluid_cricondenbar_xi(ConstArray(xi_).getData(), vleFluidPointer__ext, &d__ext, &h__ext, &p__ext, &s__ext, &T__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:8:6: note: candidate function not viable: 1st argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_cricondenbar_xi(double*, void*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:1218:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:1244:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:1270:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:1296:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:1322:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:1348:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ 16 errors generated. make: *** [: OMCppTransiEnt_TransiEnt.Producer.Heat.Power2Heat.ElectricBoiler.Check.TestPtH_limiterCalcHelperMain.o] Error 1