Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo", uses=false) Using package BuildingSystems with version 2.0.0-beta (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo) Using package NcDataReader2 with version 2.5.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest") translateModel(BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.SingleCollectorWithStorageTest") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00125/0.00125, allocations: 104.6 kB / 16.27 MB, free: 6.008 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001297/0.001297, allocations: 194 kB / 17.2 MB, free: 5.617 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.264/1.264, allocations: 222.9 MB / 240.9 MB, free: 15.22 MB / 206.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/NcDataReader2 2.5.1-master/package.mo): time 0.002052/0.002052, allocations: 283.9 kB / 291.3 MB, free: 14.53 MB / 238.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/package.mo): time 0.9176/0.9176, allocations: 169.3 MB / 0.4988 GB, free: 4.484 MB / 382.1 MB Notification: Performance of FrontEnd - loaded program: time 0.001601/0.001601, allocations: 93.55 kB / 0.5959 GB, free: 15.14 MB / 414.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1513/0.1529, allocations: 86.98 MB / 0.6808 GB, free: 8.18 MB / 494.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Technologies/SolarThermal/Examples/SingleCollectorWithStorageTest.mo:35:5-35:25:writable] Error: Modified element reverseAction not found in class LimPID. Notification: Performance of FrontEnd: time 0.3632/0.5162, allocations: 56.11 MB / 0.7356 GB, free: 13.76 MB / 0.5137 GB