Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo", uses=false) Using package ThermoPower with version 3.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com,tolerance=1e-06,outputFormat="empty",numberOfIntervals=60000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com") translateModel(ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com,tolerance=1e-06,outputFormat="empty",numberOfIntervals=60000,variableFilter="",fileNamePrefix="ThermoPower_ThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001039/0.001039, allocations: 113.5 kB / 16.62 MB, free: 6.816 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001037/0.001037, allocations: 185.8 kB / 17.55 MB, free: 5.934 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.294/1.294, allocations: 205.1 MB / 223.4 MB, free: 12.44 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/package.mo): time 0.2642/0.2642, allocations: 48.84 MB / 319.6 MB, free: 11.27 MB / 270.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001363/0.001363, allocations: 67.84 kB / 389.6 MB, free: 48.95 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.0831/0.08448, allocations: 59.15 MB / 448.7 MB, free: 10.14 MB / 334.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermoPower 3.1.0-master/PowerPlants.mo:18290:30-18290:37:writable] Error: Modified element Pn not found in class Grid. Notification: Performance of FrontEnd: time 0.03258/0.1171, allocations: 35.39 MB / 484.1 MB, free: 6.621 MB / 366.1 MB