Environment - simulationEnvironment: startTime=1.5552e+07 stopTime=1.5984e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_latest_Buildings.Utilities.Plotters.Examples.SingleZoneVAV -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS stdout | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((false)) --> "*** Warning in SingleZoneVAV.hvac.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((false)) --> "*** Warning in SingleZoneVAV.hvac.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.152714s reading init.xml | | | | | | 0.0138164s reading info.xml | | | | | | 0.00398375s [ 0.1%] pre-initialization | | | | | | 0.0375449s [ 1.1%] initialization | | | | | | 0.000135344s [ 0.0%] steps | | | | | | 0.205705s [ 6.0%] solver (excl. callbacks) | | | | | | 0.0295233s [ 0.9%] creating output-file | | | | | | 0.616846s [ 18.0%] event-handling | | | | | | 0.044149s [ 1.3%] overhead | | | | | | 2.48969s [ 72.6%] simulation | | | | | | 3.42758s [100.0%] total | | | | | events | | | | | | 80 state events | | | | | | 481 time events | | | | | solver: dassl | | | | | | 14440 steps taken | | | | | | 20066 calls of functionODE | | | | | | 7306 evaluations of jacobian | | | | | | 741 error test failures | | | | | | 1 convergence test failures | | | | | | 1.8514s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. stdout | info | Wrote plot file "/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html".