Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.Decoupling -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 21600.000002 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -1.92094e-39" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 21600.000002 | | | | ((con.pum.pumSpe.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.heaDis.etaHyd, has value: -8.65505e-36" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 79228.800000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -7.83728e-11" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 79228.800000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -9.88262e-08" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79297.920000 | | | | ((pum.pumDp.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumDp.eff.yMot, has value: -2.55962e-14" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 79297.920000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -7.98849e-28" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0773308s reading init.xml | | | | | | 0.00727664s reading info.xml | | | | | | 0.00209422s [ 0.4%] pre-initialization | | | | | | 0.00138098s [ 0.3%] initialization | | | | | | 0.000192621s [ 0.0%] steps | | | | | | 0.0249356s [ 4.7%] solver (excl. callbacks) | | | | | | 0.0130881s [ 2.5%] creating output-file | | | | | | 0.00410502s [ 0.8%] event-handling | | | | | | 0.0519869s [ 9.8%] overhead | | | | | | 0.430166s [ 81.5%] simulation | | | | | | 0.52795s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 5 time events | | | | | solver: dassl | | | | | | 4671 steps taken | | | | | | 6596 calls of functionODE | | | | | | 503 evaluations of jacobian | | | | | | 230 error test failures | | | | | | 1 convergence test failures | | | | | | 0.0777164s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.