Environment - simulationEnvironment: startTime=1.58112e+07 stopTime=1.6416e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_latest_Buildings.Fluid.DXSystems.Cooling.AirSource.Examples.SpaceCooling -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in SpaceCooling.fan: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((not (fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fan.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SpaceCooling.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan.per.haveWMot_nominal or not (fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fan.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SpaceCooling.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in SpaceCooling.fan1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((not (fan1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fan1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SpaceCooling.fan1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan1.per.haveWMot_nominal or not (fan1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fan1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SpaceCooling.fan1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in SpaceCooling.fan2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((not (fan2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fan2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in SpaceCooling.fan2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((fan2.per.haveWMot_nominal or not (fan2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fan2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in SpaceCooling.fan2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((varSpeDX.watVapEva.nomVal.gamma <= varSpeDX.watVapEva.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.52681, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.646123 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 | | | | QLat_flow_nominal = -2694 | | | | " assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((mulStaDX.watVapEva.nomVal.gamma <= mulStaDX.watVapEva.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.52681, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.646123 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 | | | | QLat_flow_nominal = -2694 | | | | " assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:185:3-194:27:writable] | | | | The following assertion has been violated during initialization at time 15811200.000000 | | | | ((sinSpeDX.watVapEva.nomVal.gamma <= sinSpeDX.watVapEva.gammaMax)) --> "*** Warning: In DX coil model, gamma is too large for these coil conditions. | | | | Instead of gamma = 1.5, a value of 0.52681, which | | | | corresponds to a mass transfer effectiveness of 0.8, will be used. | | | | Coil nominal performance data are: | | | | nomVal.m_flow_nominal = 0.646123 | | | | dX_nominal = XEvaOut_nominal-XEvaWetBulOut_nominal = 0.00528111 - 0.00637893 = -0.00109782 | | | | QLat_flow_nominal = -2694 | | | | " LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/DXSystems/Cooling/BaseClasses/PartialCapacity.mo:121:7-134:38:writable] | | | | The following assertion has been violated at time 15849076.755967 | | | | ((not (sinSpeDX.dxCoi.TEvaIn > sinSpeDX.dxCoi.dryCoi.coiCap.sta[sinSpeDX.dxCoi.dryCoi.coiCap.stage].perCur.TEvaInMax or sinSpeDX.dxCoi.TEvaIn < sinSpeDX.dxCoi.dryCoi.coiCap.sta[sinSpeDX.dxCoi.dryCoi.coiCap.stage].perCur.TEvaInMin))) --> "*** Warning: Evaporator temperature TEvaIn is out of bounds in DX coil model at time = 1.58491e+07. | | | | stage = 1 | | | | TEvaInMin = 285.928 Kelvin (12.7778 degC) | | | | TEvaIn = 297.06 Kelvin (23.9098 degC) | | | | TEvaInMax = 297.039 Kelvin (23.8889 degC) | | | | Extrapolation can introduce large errors. | | | | This warning will only be reported once for each stage." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/DXSystems/Cooling/BaseClasses/Evaporation.mo:59:3-62:61:writable] | | | | The following assertion has been violated at time 15907121.280000 | | | | ((sinSpeDX.watVapEva.m >= 0.0)) --> "Variable violating min constraint: 0.0 <= sinSpeDX.watVapEva.m, has value: -6.09714e-18" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.109176s reading init.xml | | | | | | 0.00664175s reading info.xml | | | | | | 0.00274143s [ 0.0%] pre-initialization | | | | | | 0.0374026s [ 0.2%] initialization | | | | | | 7.4991e-05s [ 0.0%] steps | | | | | | 0.55851s [ 3.1%] solver (excl. callbacks) | | | | | | 0.0416036s [ 0.2%] creating output-file | | | | | | 5.05195s [ 28.1%] event-handling | | | | | | 0.0839867s [ 0.5%] overhead | | | | | | 12.2271s [ 67.9%] simulation | | | | | | 18.0034s [100.0%] total | | | | | events | | | | | | 2356 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 125784 steps taken | | | | | | 162539 calls of functionODE | | | | | | 33850 evaluations of jacobian | | | | | | 3122 error test failures | | | | | | 0 convergence test failures | | | | | | 6.82762s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.