Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_3.0.0_Buildings.Controls.OBC.ASHRAE.G36.TerminalUnits.DualDuctColdDuctMin.Validation.Controller -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel5.y)) --> "Warning: the hot-duct damper is leaking." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not duaDucCon.ala.truDel3.y)) --> "Warning: the cold-duct damper is leaking." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 2160.000000 | | | | ((duaDucCon.gre.greHys.y)) --> "Warning: the sum of minimum flow and heating maximum flow is greater than the cooling maximum flow." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 2160.000000 | | | | ((duaDucCon.actAirSet.gre.greHys.y)) --> "Warning: the sum of minimum flow and heating maximum flow is greater than the cooling maximum flow." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 12080.000001 | | | | ((not duaDucCon.ala.truDel4.y)) --> "Warning: hot-duct airflow sensor should be calibrated." assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Controls/OBC/CDL/Utilities/Assert.mo:11:3-14:28:writable] | | | | The following assertion has been violated at time 12080.000001 | | | | ((not duaDucCon.ala.truDel2.y)) --> "Warning: cold-duct airflow sensor should be calibrated." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0234876s reading init.xml | | | | | | 0.00190572s reading info.xml | | | | | | 0.00026127s [ 0.3%] pre-initialization | | | | | | 0.00028302s [ 0.3%] initialization | | | | | | 1.576e-05s [ 0.0%] steps | | | | | | 0.0179932s [ 18.9%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0371525s [ 39.1%] event-handling | | | | | | 0.00128838s [ 1.4%] overhead | | | | | | 0.0381276s [ 40.1%] simulation | | | | | | 0.0951217s [100.0%] total | | | | | events | | | | | | 53 state events | | | | | | 724 time events | | | | | solver: dassl | | | | | | 11585 steps taken | | | | | | 13382 calls of functionODE | | | | | | 10058 evaluations of jacobian | | | | | | 53 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00965161s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.