Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.MultipleBuildings.ThreeZonesTwoBuildings -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS stdout | info | ... loading "EnergyPlus" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Resources/Data/ThermalZones/EnergyPlus_9_6_0/Validation/TwoIdenticalZones/TwoIdenticalZones.dat" EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.20 08:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.20 08:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD stdout | info | Output ThreeZonesTwoBuildings.zon2.inf1.y has in Modelica the unit 1. assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zon2.zon1.duc.m_flow >= 0.0 and zon2.zon1.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= zon2.zon1.duc.m_flow <= 100000.0, has value: -2.73576e-14" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zon2.zon2.duc.m_flow >= 0.0 and zon2.zon2.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= zon2.zon2.duc.m_flow <= 100000.0, has value: -1.36788e-14" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((zon1.duc.m_flow >= 0.0 and zon1.duc.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= zon1.duc.m_flow <= 100000.0, has value: -2.63739e-14" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0218672s reading init.xml | | | | | | 0.00181055s reading info.xml | | | | | | 0.000558307s [ 0.0%] pre-initialization | | | | | | 15.3871s [ 98.5%] initialization | | | | | | 1.4948e-05s [ 0.0%] steps | | | | | | 0.00867187s [ 0.1%] solver (excl. callbacks) | | | | | | 0.00493794s [ 0.0%] creating output-file | | | | | | 0.0923044s [ 0.6%] event-handling | | | | | | 0.0134695s [ 0.1%] overhead | | | | | | 0.109549s [ 0.7%] simulation | | | | | | 15.6166s [100.0%] total | | | | | events | | | | | | 143 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2525 steps taken | | | | | | 2937 calls of functionODE | | | | | | 2152 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.0183531s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 8.18sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. Writing final SQL reports EnergyPlus Run Time=00hr 00min 0.51sec EnergyPlus Completed Successfully. stdout | info | 85800.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: The following schedule names are "Unused Schedules". These schedules are in the idf stdout | info | 85800.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. stdout | info | 85800.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: The following week schedule names are "Unused Schedules". These schedules are in the idf stdout | info | 85800.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used. stdout | info | 85800.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: The following day schedule names are "Unused Schedules". These schedules are in the idf stdout | info | 85800.000 ThreeZonesTwoBuildings.zon2.building: Warning from EnergyPlus: file but are never obtained by the simulation and therefore are NOT used.