Environment - simulationEnvironment: startTime=432000 stopTime=864000 tolerance=1e-07 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_10_Buildings.ThermalZones.EnergyPlus_9_6_0.Examples.SmallOffice.ASHRAE2006Winter -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.04.20 08:14 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 432086.400000 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -3.15117e-67" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 432691.200000 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -2.73945e-21" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 432691.200000 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -6.75324e-17" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 437529.600000 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -5.06562e-10" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 437529.600000 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -3.47677e-10" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 437529.600000 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -5.06562e-10" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 437529.600000 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -3.47677e-10" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 437529.600000 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -6.68229e-10" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 500515.200000 | | | | ((hvac.pumHeaCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.etaHyd, has value: -4.29709e-30" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:115:3-116:81:writable] | | | | The following assertion has been violated at time 500515.200000 | | | | ((hvac.pumHeaCoi.m_flow >= 0.0 and hvac.pumHeaCoi.m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumHeaCoi.m_flow <= 100000.0, has value: -4.79914e-16" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 500515.200000 | | | | ((hvac.pumHeaCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.heaDis.etaHyd, has value: -3.82099e-29" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 500601.600000 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -7.27197e-51" Updating Shadowing Calculations, Start Date=01/08/2017 Continuing Simulation at 01/08/2017 for SPAWN-RUNPERIOD assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 711244.800000 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -1.06295e-73" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.140533s reading init.xml | | | | | | 0.0117523s reading info.xml | | | | | | 0.00261916s [ 0.0%] pre-initialization | | | | | | 7.92343s [ 16.4%] initialization | | | | | | 0.00952321s [ 0.0%] steps | | | | | | 1.4833s [ 3.1%] solver (excl. callbacks) | | | | | | 0.0677586s [ 0.1%] creating output-file | | | | | | 4.85968s [ 10.1%] event-handling | | | | | | 0.0848485s [ 0.2%] overhead | | | | | | 33.778s [ 70.1%] simulation | | | | | | 48.2092s [100.0%] total | | | | | events | | | | | | 801 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 49647 steps taken | | | | | | 79098 calls of functionODE | | | | | | 25093 evaluations of jacobian | | | | | | 1515 error test failures | | | | | | 4377 convergence test failures | | | | | | 30.0544s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 40.87sec EnergyPlus Completed Successfully.