Environment - simulationEnvironment: startTime=2.592e+06 stopTime=3.6288e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=414.72 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.Loads.Heating.Examples.BuildingTimeSeriesWithETS -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Resources/Data/Experimental/DHC/Loads/Examples/MediumOffice-90.1-2010-5A.mos" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 2592000.000000 | | | | ((false)) --> "*** Warning in BuildingTimeSeriesWithETS.buiWitETS.bui.terUniHea.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 2592000.000000 | | | | ((false)) --> "*** Warning in BuildingTimeSeriesWithETS.buiWitETS.bui.terUniHea.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0316724s reading init.xml | | | | | | 0.00312707s reading info.xml | | | | | | 0.00119117s [ 0.6%] pre-initialization | | | | | | 0.00321099s [ 1.7%] initialization | | | | | | 9.808e-06s [ 0.0%] steps | | | | | | 0.0132536s [ 7.1%] solver (excl. callbacks) | | | | | | 0.00420205s [ 2.3%] creating output-file | | | | | | 0.00263978s [ 1.4%] event-handling | | | | | | 0.0193288s [ 10.4%] overhead | | | | | | 0.142549s [ 76.5%] simulation | | | | | | 0.186385s [100.0%] total | | | | | events | | | | | | 24 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 8189 steps taken | | | | | | 13474 calls of functionODE | | | | | | 1376 evaluations of jacobian | | | | | | 614 error test failures | | | | | | 19 convergence test failures | | | | | | 0.0289804s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.