Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.Loads.BaseClasses.Validation.TerminalUnitScaling -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in TerminalUnitScaling.ter.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in TerminalUnitScaling.ter.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in TerminalUnitScaling.terUniMul.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in TerminalUnitScaling.terUniMul.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in TerminalUnitScaling.terUniMulZonMul.fan: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in TerminalUnitScaling.terUniMulZonMul.fan: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.041667 | | | | ((sinHeaWat.ports[2].m_flow >= 0.0 and sinHeaWat.ports[2].m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= sinHeaWat.ports[2].m_flow <= 100000.0, has value: -6.01853e-36" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.041667 | | | | ((sinHeaWat.ports[3].m_flow >= 0.0 and sinHeaWat.ports[3].m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= sinHeaWat.ports[3].m_flow <= 100000.0, has value: -1.20371e-35" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 0.041667 | | | | ((terUniMul.hex.m1_flow >= 0.0 and terUniMul.hex.m1_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= terUniMul.hex.m1_flow <= 100000.0, has value: -3.00927e-36" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.041667 | | | | ((supHeaWat1.ports[1].m_flow >= -100000.0 and supHeaWat1.ports[1].m_flow <= 0.0)) --> "Variable violating min/max constraint: -100000.0 <= supHeaWat1.ports[1].m_flow <= 0.0, has value: 6.01853e-36" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 0.041667 | | | | ((terUniMulZonMul.hex.m1_flow >= 0.0 and terUniMulZonMul.hex.m1_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= terUniMulZonMul.hex.m1_flow <= 100000.0, has value: -3.00927e-36" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.041667 | | | | ((supHeaWat2.ports[1].m_flow >= -100000.0 and supHeaWat2.ports[1].m_flow <= 0.0)) --> "Variable violating min/max constraint: -100000.0 <= supHeaWat2.ports[1].m_flow <= 0.0, has value: 1.20371e-35" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0355326s reading init.xml | | | | | | 0.00310344s reading info.xml | | | | | | 0.00118778s [ 2.1%] pre-initialization | | | | | | 0.000601698s [ 1.0%] initialization | | | | | | 5.39e-06s [ 0.0%] steps | | | | | | 0.00133127s [ 2.3%] solver (excl. callbacks) | | | | | | 0.00354599s [ 6.2%] creating output-file | | | | | | 0.000709501s [ 1.2%] event-handling | | | | | | 0.01234s [ 21.5%] overhead | | | | | | 0.0376326s [ 65.6%] simulation | | | | | | 0.0573542s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 238 steps taken | | | | | | 350 calls of functionODE | | | | | | 75 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000509479s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.