Environment - simulationEnvironment: startTime=0 stopTime=360000 tolerance=1e-06 numberOfIntervals=2500 stepSize=144 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerBorefield -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS stdout | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" stdout | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.hex.pum1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.hex.pum1.per.haveWMot_nominal or not (ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.hex.pum1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.hex.pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.hex.pum2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.hex.pum2.per.haveWMot_nominal or not (ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.hex.pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.hex.pum2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumCon.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.chi.pumCon: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.chi.pumCon.per.haveWMot_nominal or not (ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumCon.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.chi.pumCon: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.chi.pumEva.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.chi.pumEva: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.chi.pumEva.per.haveWMot_nominal or not (ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.chi.pumEva.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.chi.pumEva: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (ets.borFie.pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or ets.borFie.pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.ets.borFie.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ets.borFie.pum.per.haveWMot_nominal or not (ets.borFie.pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or ets.borFie.pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.ets.borFie.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumChiWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.pumChiWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumChiWat.per.haveWMot_nominal or not (pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumChiWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.pumChiWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumHeaWat.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in ChillerBorefield.pumHeaWat: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pumHeaWat.per.haveWMot_nominal or not (pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumHeaWat.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in ChillerBorefield.pumHeaWat: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." stdout | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" stdout | info | ... loading "TStep" from "tmp/temperatureResponseMatrix/a61a052f480aedd8ecca298fe2b38b7cda930158TStep.mat" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Interfaces/PartialFourPortInterface.mo:28:3-29:84:writable] | | | | The following assertion has been violated at time 3840.000000 | | | | ((ets.hex.m2_flow >= 0.0 and ets.hex.m2_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.hex.m2_flow <= 100000.0, has value: -7.3727e-16" assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Experimental/DHC/Networks/BaseClasses/PartialDistribution2Pipe.mo:81:3-85:55:writable] | | | | The following assertion has been violated at time 28312.738701 | | | | ((ets.colHeaWat.mCon_flow[2] >= 0.0 and ets.colHeaWat.mCon_flow[2] <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= ets.colHeaWat.mCon_flow[2] <= 100000.0, has value: -4.42354e-20" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.245014s reading init.xml | | | | | | 0.0212374s reading info.xml | | | | | | 0.00748016s [ 0.0%] pre-initialization | | | | | | 38.1047s [ 49.8%] initialization | | | | | | 0.00452135s [ 0.0%] steps | | | | | | 2.96377s [ 3.9%] solver (excl. callbacks) | | | | | | 0.171403s [ 0.2%] creating output-file | | | | | | 2.89911s [ 3.8%] event-handling | | | | | | 0.21582s [ 0.3%] overhead | | | | | | 32.2045s [ 42.1%] simulation | | | | | | 76.5713s [100.0%] total | | | | | events | | | | | | 267 state events | | | | | | 6001 time events | | | | | solver: dassl | | | | | | 93147 steps taken | | | | | | 116840 calls of functionODE | | | | | | 67625 evaluations of jacobian | | | | | | 1054 error test failures | | | | | | 5 convergence test failures | | | | | | 29.8211s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.