Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.008 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.Examples.Performance.Example2 -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-426:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump_dp.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_dp.per.etaHydMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in Example2.pump_dp: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided." assert | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:428:3-437:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_dp.per.haveWMot_nominal or not (pump_dp.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump_dp.per.etaMotMet == BuildingSystems.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in Example2.pump_dp: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.500000 | | | | ((res[6].m_flow >= 0.0 and res[6].m_flow <= 100000.0)) --> "Variable violating min/max constraint: 0.0 <= res[6].m_flow <= 100000.0, has value: -4.08557e-12" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00736952s reading init.xml | | | | | | 0.00077364s reading info.xml | | | | | | 8.3877e-05s [ 0.4%] pre-initialization | | | | | | 0.000350517s [ 1.8%] initialization | | | | | | 1.5809e-05s [ 0.1%] steps | | | | | | 0.000917861s [ 4.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000866704s [ 4.4%] event-handling | | | | | | 0.00426512s [ 21.6%] overhead | | | | | | 0.0132617s [ 67.1%] simulation | | | | | | 0.0197616s [100.0%] total | | | | | events | | | | | | 40 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 697 steps taken | | | | | | 697 calls of functionODE | | | | | | 656 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000776128s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.