Environment - simulationEnvironment: startTime=0 stopTime=80 tolerance=1e-06 numberOfIntervals=500 stepSize=0.16 Regular simulation: ./PowerGrids_dev_PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS stdout | info | Using sparse solver for linear system 0, | | | | because density of 0.111 remains under threshold of 0.200. stdout | info | Using sparse solver for linear system 1, | | | | because density of 0.172 remains under threshold of 0.200. stdout | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. stdout | warning | Internal Numerical Jacobians without coloring are currently not supported by IDA with KLU. Colored numerical Jacobian will be used. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | busLoad.VPuCheck < busLoad.VPuMax assert | warning | Voltage too high (VPu=2.998 > 1.3), check if the numerical solution is valid assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | infiniteBus.componentPF.VPuCheck > infiniteBus.componentPF.VPuMin assert | warning | Voltage too low (VPu=0.502 < 0.7), check if the numerical solution is valid assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | busLoad.componentPF.VPuCheck < busLoad.componentPF.VPuMax assert | warning | Voltage too high (VPu=1.50549 > 1.3), check if the numerical solution is valid LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | The following assertion has been violated at time 4.665070 | | | | infiniteBus.VPuCheck < infiniteBus.VPuMax assert | info | Voltage too high (VPu=1.33433 > 1.3), check if the numerical solution is valid assert | info | The following assertion has been violated at time 24.652391 | | | | infiniteBus.VPuCheck > infiniteBus.VPuMin assert | info | Voltage too low (VPu=0.667 < 0.7), check if the numerical solution is valid LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00931872s reading init.xml | | | | | | 0.00109735s reading info.xml | | | | | | 0.00234508s [ 12.4%] pre-initialization | | | | | | 0.000452278s [ 2.4%] initialization | | | | | | 2.615e-06s [ 0.0%] steps | | | | | | 0.0106007s [ 56.3%] solver (excl. callbacks) | | | | | | 0.00054272s [ 2.9%] creating output-file | | | | | | 0.00494602s [ 26.2%] event-handling | | | | | | 0.00153711s [ 8.2%] overhead | | | | | | -0.00158452s [ -8.4%] simulation | | | | | | 0.018842s [100.0%] total | | | | | events | | | | | | 31 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 610 steps taken | | | | | | 756 calls of functionODE | | | | | | 361 evaluations of jacobian | | | | | | 3 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00241623s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.