Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo", uses=false) Using package IndustrialControlSystems with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode") translateModel(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001089/0.00109, allocations: 111.3 kB / 15.23 MB, free: 0.6406 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001843/0.001843, allocations: 195.9 kB / 16.14 MB, free: 6.711 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.598/1.598, allocations: 205.1 MB / 222 MB, free: 4.809 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo): time 0.05902/0.05902, allocations: 10.74 MB / 280.1 MB, free: 10.73 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002031/0.002031, allocations: 63.91 kB / 339.9 MB, free: 23.78 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1197/0.1217, allocations: 49.03 MB / 388.9 MB, free: 6.691 MB / 286.1 MB Notification: Performance of NFInst.instantiate(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode): time 0.004542/0.1263, allocations: 3.219 MB / 392.1 MB, free: 3.441 MB / 286.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/Controllers/AutoTuning/ATPIrelayNCmixedMode.mo:91:8-91:29:writable] Error: Operator reinit may not be used in an algorithm section (use translation flag --allowNonStandardModelica=reinitInAlgorithms to ignore). Notification: Performance of FrontEnd: time 0.000326/0.1267, allocations: 171.8 kB / 392.3 MB, free: 3.273 MB / 286.1 MB