Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr IDEAS_IDEAS.Buildings.Validation.Tests.Case650FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo", uses=false) Using package IDEAS with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IDEAS.Buildings.Validation.Tests.Case650FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Buildings.Validation.Tests.Case650FF") translateModel(IDEAS.Buildings.Validation.Tests.Case650FF,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="IDEAS_IDEAS.Buildings.Validation.Tests.Case650FF") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001224/0.001224, allocations: 111.3 kB / 15.23 MB, free: 0.6602 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001474/0.001474, allocations: 192.5 kB / 16.13 MB, free: 6.703 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.354/1.354, allocations: 222.9 MB / 239.8 MB, free: 4.598 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/package.mo): time 0.78/0.78, allocations: 132.2 MB / 422.2 MB, free: 1.988 MB / 350.1 MB Warning: Ignoring unknown experiment annotation option: __Dymola_Algorithm = "Lsodar" Notification: Performance of FrontEnd - loaded program: time 0.001212/0.001212, allocations: 60.06 kB / 0.5011 GB, free: 9.18 MB / 414.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2139/0.2151, allocations: 80.2 MB / 0.5794 GB, free: 9.199 MB / 494.1 MB Notification: Performance of NFInst.instantiate(IDEAS.Buildings.Validation.Tests.Case650FF): time 2.281/2.497, allocations: 0.6018 GB / 1.181 GB, free: 14.43 MB / 0.8106 GB Notification: Performance of NFInst.instExpressions: time 0.378/2.875, allocations: 235.7 MB / 1.411 GB, free: 6.41 MB / 0.8731 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.09143/2.966, allocations: 1.19 MB / 1.412 GB, free: 5.215 MB / 0.8731 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/InterzonalAirFlow/BaseClasses/PartialInterzonalAirFlowBoundary.mo:21:3-22:72:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialZone.mo:195:3-207:27:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Zone.mo:6:3-18:28:writable] Warning: Connector propsBus is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/BoundaryWall.mo:64:3-66:71:writable] Warning: Connector weaBus is not balanced: The number of potential variables (20) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:55:3-69:26:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:8:3-16:27:writable] Warning: Connector propsBus_a is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/ZoneBusVarMultiplicator.mo:18:3-26:26:writable] Warning: Connector propsBus_b is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Buildings/Components/Interfaces/PartialSurface.mo:145:3-157:26:writable] Warning: Connector propsBusInt is not balanced: The number of potential variables (10) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.02237/2.989, allocations: 6.878 MB / 1.419 GB, free: 15.1 MB / 0.8887 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Templates/Interfaces/BaseClasses/Structure.mo:50:63-50:98:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IDEAS 3.0.0/Templates/Interfaces/BaseClasses/Structure.mo:50:3-52:73:writable] Error: Non-array modification ‘"ThermodynamicTemperature"‘ for array component ‘quantity‘, possibly due to missing ‘each‘. Notification: Performance of FrontEnd: time 0.0002301/2.989, allocations: 42.89 kB / 1.419 GB, free: 15.07 MB / 0.8887 GB