Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr ClaRa_ClaRa.StaticCycles.Check.TestStacy6.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo", uses=false) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo) Running command: translateModel(ClaRa.StaticCycles.Check.TestStacy6,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="Time|staCy.Pump_preheater_LP3.outlet.m_flow|staCy.Pump_preheater_LP3.summary.outlet.m_flow|staCy.condenser.outlet.m_flow|staCy.condenser.summary.outlet.m_flow|staCy.feedwatertank.cond_out.m_flow|staCy.feedwatertank.summary.outlet_cond.m_flow|staCy.mixer.outlet.m_flow|staCy.mixer.summary.outlet.m_flow|staCy.mixer1.outlet.m_flow|staCy.mixer1.summary.outlet.m_flow|staCy.mixer3.outlet.m_flow|staCy.mixer3.summary.outlet.m_flow|staCy.mixer3_1.outlet.m_flow|staCy.mixer3_1.summary.outlet.m_flow|staCy.mixer3_2.outlet.m_flow|staCy.mixer3_2.summary.outlet.m_flow|staCy.mixer4_1.outlet.m_flow|staCy.mixer4_1.summary.outlet.m_flow|staCy.preheater_HP.cond_out.m_flow|staCy.preheater_HP.summary.outlet_cond.m_flow|staCy.preheater_HP.summary.outlet_tap.m_flow|staCy.preheater_HP.tap_out.m_flow|staCy.preheater_HP_IP1.cond_out.m_flow|staCy.preheater_HP_IP1.summary.outlet_cond.m_flow|staCy.preheater_HP_IP1.summary.outlet_tap.m_flow|staCy.preheater_HP_IP1.tap_out.m_flow|staCy.preheater_IP1.cond_out.m_flow|staCy.preheater_IP1.summary.outlet_cond.m_flow|staCy.preheater_IP1.summary.outlet_tap.m_flow|staCy.preheater_IP1.tap_out.m_flow|staCy.preheater_IP3.cond_out.m_flow|staCy.preheater_IP3.summary.outlet_cond.m_flow|staCy.preheater_IP3.summary.outlet_tap.m_flow|staCy.preheater_IP3.tap_out.m_flow|staCy.preheater_LP1.cond_out.m_flow|staCy.preheater_LP1.summary.outlet_cond.m_flow|staCy.preheater_LP1.summary.outlet_tap.m_flow|staCy.preheater_LP1.tap_out.m_flow|staCy.preheater_LP2.cond_out.m_flow|staCy.preheater_LP2.summary.outlet_cond.m_flow|staCy.preheater_LP2.summary.outlet_tap.m_flow|staCy.preheater_LP2.tap_out.m_flow|staCy.preheater_LP3.cond_out.m_flow|staCy.preheater_LP3.summary.outlet_cond.m_flow|staCy.preheater_LP3.summary.outlet_tap.m_flow|staCy.preheater_LP3.tap_out.m_flow|staCy.pump_cond.outlet.m_flow|staCy.pump_cond.summary.outlet.m_flow|staCy.pump_fw.outlet.m_flow|staCy.pump_fw.summary.outlet.m_flow|staCy.pump_preheater_IP3.outlet.m_flow|staCy.pump_preheater_IP3.summary.outlet.m_flow|staCy.pump_preheater_LP2.outlet.m_flow|staCy.pump_preheater_LP2.summary.outlet.m_flow|staCy.split_LP.outlet_1.m_flow|staCy.split_LP.outlet_2.m_flow|staCy.split_LP.summary.outlet1.m_flow|staCy.split_LP.summary.outlet2.m_flow|staCy.split_LP1.outlet_1.m_flow|staCy.split_LP1.outlet_2.m_flow|staCy.split_LP1.summary.outlet1.m_flow|staCy.split_LP1.summary.outlet2.m_flow|staCy.split_LP2.outlet_1.m_flow|staCy.split_LP2.outlet_2.m_flow|staCy.split_LP2.summary.outlet1.m_flow|staCy.split_LP2.summary.outlet2.m_flow|staCy.split_LP3.outlet_1.m_flow|staCy.split_LP3.outlet_2.m_flow|staCy.split_LP3.summary.outlet1.m_flow|staCy.split_LP3.summary.outlet2.m_flow|staCy.split_LP4.outlet_1.m_flow|staCy.split_LP4.outlet_2.m_flow|staCy.split_LP4.summary.outlet1.m_flow|staCy.split_LP4.summary.outlet2.m_flow|staCy.split_LP5.outlet_1.m_flow|staCy.split_LP5.outlet_2.m_flow|staCy.split_LP5.summary.outlet1.m_flow|staCy.split_LP5.summary.outlet2.m_flow|staCy.split_LP_turbine2.outlet_1.m_flow|staCy.split_LP_turbine2.outlet_2.m_flow|staCy.split_LP_turbine2.summary.outlet1.m_flow|staCy.split_LP_turbine2.summary.outlet2.m_flow|staCy.turbine_HP.outlet.m_flow|staCy.turbine_HP.summary.outlet.m_flow|staCy.turbine_IP1.outlet.m_flow|staCy.turbine_IP1.summary.outlet.m_flow|staCy.turbine_IP2.outlet.m_flow|staCy.turbine_IP2.summary.outlet.m_flow|staCy.turbine_IP3.outlet.m_flow|staCy.turbine_IP3.summary.outlet.m_flow|staCy.turbine_LP1.outlet.m_flow|staCy.turbine_LP1.summary.outlet.m_flow|staCy.turbine_LP2.outlet.m_flow|staCy.turbine_LP2.summary.outlet.m_flow|staCy.turbine_LP3.outlet.m_flow|staCy.turbine_LP3.summary.outlet.m_flow|staCy.turbine_LP4.outlet.m_flow|staCy.turbine_LP4.summary.outlet.m_flow|staCy.valve1.outlet.m_flow|staCy.valve1.summary.outlet.m_flow|staCy.valve2.outlet.m_flow|staCy.valve2.summary.outlet.m_flow|staCy.valve3.outlet.m_flow|staCy.valve3.summary.outlet.m_flow|staCy.valve4.outlet.m_flow|staCy.valve4.summary.outlet.m_flow|staCy.valve5.outlet.m_flow|staCy.valve5.summary.outlet.m_flow|staCy.valve_IP1.outlet.m_flow|staCy.valve_IP1.summary.outlet.m_flow|staCy.valve_IP2.outlet.m_flow|staCy.valve_IP2.summary.outlet.m_flow|staCy.valve_IP3.outlet.m_flow|staCy.valve_IP3.summary.outlet.m_flow|staCy.valve_IP_control.outlet.m_flow|staCy.valve_IP_control.summary.outlet.m_flow|staCy.valve_LP1.outlet.m_flow|staCy.valve_LP1.summary.outlet.m_flow|staCy.valve_LP2.outlet.m_flow|staCy.valve_LP2.summary.outlet.m_flow|staCy.valve_LP3.outlet.m_flow|staCy.valve_LP3.summary.outlet.m_flow|staCy.valve_dp_nom.outlet.m_flow|staCy.valve_dp_nom.summary.outlet.m_flow|staCy.valve_dp_nom2_1.outlet.m_flow|staCy.valve_dp_nom2_1.summary.outlet.m_flow|staCy.valve_dp_nom3_1.outlet.m_flow|staCy.valve_dp_nom3_1.summary.outlet.m_flow",fileNamePrefix="ClaRa_ClaRa.StaticCycles.Check.TestStacy6") translateModel(ClaRa.StaticCycles.Check.TestStacy6,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="Time|staCy.Pump_preheater_LP3.outlet.m_flow|staCy.Pump_preheater_LP3.summary.outlet.m_flow|staCy.condenser.outlet.m_flow|staCy.condenser.summary.outlet.m_flow|staCy.feedwatertank.cond_out.m_flow|staCy.feedwatertank.summary.outlet_cond.m_flow|staCy.mixer.outlet.m_flow|staCy.mixer.summary.outlet.m_flow|staCy.mixer1.outlet.m_flow|staCy.mixer1.summary.outlet.m_flow|staCy.mixer3.outlet.m_flow|staCy.mixer3.summary.outlet.m_flow|staCy.mixer3_1.outlet.m_flow|staCy.mixer3_1.summary.outlet.m_flow|staCy.mixer3_2.outlet.m_flow|staCy.mixer3_2.summary.outlet.m_flow|staCy.mixer4_1.outlet.m_flow|staCy.mixer4_1.summary.outlet.m_flow|staCy.preheater_HP.cond_out.m_flow|staCy.preheater_HP.summary.outlet_cond.m_flow|staCy.preheater_HP.summary.outlet_tap.m_flow|staCy.preheater_HP.tap_out.m_flow|staCy.preheater_HP_IP1.cond_out.m_flow|staCy.preheater_HP_IP1.summary.outlet_cond.m_flow|staCy.preheater_HP_IP1.summary.outlet_tap.m_flow|staCy.preheater_HP_IP1.tap_out.m_flow|staCy.preheater_IP1.cond_out.m_flow|staCy.preheater_IP1.summary.outlet_cond.m_flow|staCy.preheater_IP1.summary.outlet_tap.m_flow|staCy.preheater_IP1.tap_out.m_flow|staCy.preheater_IP3.cond_out.m_flow|staCy.preheater_IP3.summary.outlet_cond.m_flow|staCy.preheater_IP3.summary.outlet_tap.m_flow|staCy.preheater_IP3.tap_out.m_flow|staCy.preheater_LP1.cond_out.m_flow|staCy.preheater_LP1.summary.outlet_cond.m_flow|staCy.preheater_LP1.summary.outlet_tap.m_flow|staCy.preheater_LP1.tap_out.m_flow|staCy.preheater_LP2.cond_out.m_flow|staCy.preheater_LP2.summary.outlet_cond.m_flow|staCy.preheater_LP2.summary.outlet_tap.m_flow|staCy.preheater_LP2.tap_out.m_flow|staCy.preheater_LP3.cond_out.m_flow|staCy.preheater_LP3.summary.outlet_cond.m_flow|staCy.preheater_LP3.summary.outlet_tap.m_flow|staCy.preheater_LP3.tap_out.m_flow|staCy.pump_cond.outlet.m_flow|staCy.pump_cond.summary.outlet.m_flow|staCy.pump_fw.outlet.m_flow|staCy.pump_fw.summary.outlet.m_flow|staCy.pump_preheater_IP3.outlet.m_flow|staCy.pump_preheater_IP3.summary.outlet.m_flow|staCy.pump_preheater_LP2.outlet.m_flow|staCy.pump_preheater_LP2.summary.outlet.m_flow|staCy.split_LP.outlet_1.m_flow|staCy.split_LP.outlet_2.m_flow|staCy.split_LP.summary.outlet1.m_flow|staCy.split_LP.summary.outlet2.m_flow|staCy.split_LP1.outlet_1.m_flow|staCy.split_LP1.outlet_2.m_flow|staCy.split_LP1.summary.outlet1.m_flow|staCy.split_LP1.summary.outlet2.m_flow|staCy.split_LP2.outlet_1.m_flow|staCy.split_LP2.outlet_2.m_flow|staCy.split_LP2.summary.outlet1.m_flow|staCy.split_LP2.summary.outlet2.m_flow|staCy.split_LP3.outlet_1.m_flow|staCy.split_LP3.outlet_2.m_flow|staCy.split_LP3.summary.outlet1.m_flow|staCy.split_LP3.summary.outlet2.m_flow|staCy.split_LP4.outlet_1.m_flow|staCy.split_LP4.outlet_2.m_flow|staCy.split_LP4.summary.outlet1.m_flow|staCy.split_LP4.summary.outlet2.m_flow|staCy.split_LP5.outlet_1.m_flow|staCy.split_LP5.outlet_2.m_flow|staCy.split_LP5.summary.outlet1.m_flow|staCy.split_LP5.summary.outlet2.m_flow|staCy.split_LP_turbine2.outlet_1.m_flow|staCy.split_LP_turbine2.outlet_2.m_flow|staCy.split_LP_turbine2.summary.outlet1.m_flow|staCy.split_LP_turbine2.summary.outlet2.m_flow|staCy.turbine_HP.outlet.m_flow|staCy.turbine_HP.summary.outlet.m_flow|staCy.turbine_IP1.outlet.m_flow|staCy.turbine_IP1.summary.outlet.m_flow|staCy.turbine_IP2.outlet.m_flow|staCy.turbine_IP2.summary.outlet.m_flow|staCy.turbine_IP3.outlet.m_flow|staCy.turbine_IP3.summary.outlet.m_flow|staCy.turbine_LP1.outlet.m_flow|staCy.turbine_LP1.summary.outlet.m_flow|staCy.turbine_LP2.outlet.m_flow|staCy.turbine_LP2.summary.outlet.m_flow|staCy.turbine_LP3.outlet.m_flow|staCy.turbine_LP3.summary.outlet.m_flow|staCy.turbine_LP4.outlet.m_flow|staCy.turbine_LP4.summary.outlet.m_flow|staCy.valve1.outlet.m_flow|staCy.valve1.summary.outlet.m_flow|staCy.valve2.outlet.m_flow|staCy.valve2.summary.outlet.m_flow|staCy.valve3.outlet.m_flow|staCy.valve3.summary.outlet.m_flow|staCy.valve4.outlet.m_flow|staCy.valve4.summary.outlet.m_flow|staCy.valve5.outlet.m_flow|staCy.valve5.summary.outlet.m_flow|staCy.valve_IP1.outlet.m_flow|staCy.valve_IP1.summary.outlet.m_flow|staCy.valve_IP2.outlet.m_flow|staCy.valve_IP2.summary.outlet.m_flow|staCy.valve_IP3.outlet.m_flow|staCy.valve_IP3.summary.outlet.m_flow|staCy.valve_IP_control.outlet.m_flow|staCy.valve_IP_control.summary.outlet.m_flow|staCy.valve_LP1.outlet.m_flow|staCy.valve_LP1.summary.outlet.m_flow|staCy.valve_LP2.outlet.m_flow|staCy.valve_LP2.summary.outlet.m_flow|staCy.valve_LP3.outlet.m_flow|staCy.valve_LP3.summary.outlet.m_flow|staCy.valve_dp_nom.outlet.m_flow|staCy.valve_dp_nom.summary.outlet.m_flow|staCy.valve_dp_nom2_1.outlet.m_flow|staCy.valve_dp_nom2_1.summary.outlet.m_flow|staCy.valve_dp_nom3_1.outlet.m_flow|staCy.valve_dp_nom3_1.summary.outlet.m_flow",fileNamePrefix="ClaRa_ClaRa.StaticCycles.Check.TestStacy6") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo): time 0.1354/0.1354, allocations: 22.38 MB / 37.5 MB, free: 2.25 MB / 26.18 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009759/0.0009758, allocations: 100.1 kB / 44.64 MB, free: 4.438 MB / 34.91 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001488/0.001488, allocations: 191.2 kB / 51.89 MB, free: 8.816 MB / 46.55 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.545/1.545, allocations: 222.9 MB / 281.9 MB, free: 2.34 MB / 206.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/package.mo): time 0.906/0.906, allocations: 126.8 MB / 465.2 MB, free: 12.55 MB / 366.1 MB Warning: Ignoring unknown experiment annotation option: method = "dassl" Notification: Performance of FrontEnd - loaded program: time 0.001763/0.001763, allocations: 90.67 kB / 0.546 GB, free: 44.74 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2219/0.2237, allocations: 81.79 MB / 0.6259 GB, free: 4.172 MB / 446.1 MB Notification: Performance of NFInst.instantiate(ClaRa.StaticCycles.Check.TestStacy6): time 0.1056/0.3293, allocations: 115.8 MB / 0.739 GB, free: 24 kB / 0.545 GB Notification: Performance of NFInst.instExpressions: time 0.5746/0.904, allocations: 52.02 MB / 0.7898 GB, free: 17.68 MB / 0.5607 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.03395/0.9381, allocations: 405.3 kB / 0.7902 GB, free: 17.68 MB / 0.5607 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). Notification: Performance of NFTyping.typeComponents: time 0.0115/0.9496, allocations: 3.159 MB / 0.7933 GB, free: 17.15 MB / 0.5607 GB Notification: Performance of NFTyping.typeBindings: time 0.01952/0.9692, allocations: 3.571 MB / 0.7968 GB, free: 16.12 MB / 0.5607 GB Notification: Performance of NFTyping.typeClassSections: time 0.009297/0.9785, allocations: 1.713 MB / 0.7984 GB, free: 16.03 MB / 0.5607 GB Notification: Performance of NFFlatten.flatten: time 0.02213/1.001, allocations: 9.957 MB / 0.8082 GB, free: 11.39 MB / 0.5607 GB Notification: Performance of NFFlatten.resolveConnections: time 0.007884/1.009, allocations: 3.879 MB / 0.812 GB, free: 9.852 MB / 0.5607 GB Notification: Performance of NFEvalConstants.evaluate: time 0.01403/1.023, allocations: 5.172 MB / 0.817 GB, free: 7.152 MB / 0.5607 GB Notification: Performance of NFSimplifyModel.simplify: time 0.01074/1.033, allocations: 4.272 MB / 0.8212 GB, free: 4.344 MB / 0.5607 GB Notification: Performance of NFPackage.collectConstants: time 0.004437/1.038, allocations: 0.4915 MB / 0.8217 GB, free: 4.344 MB / 0.5607 GB Notification: Performance of NFFlatten.collectFunctions: time 0.01151/1.049, allocations: 1.623 MB / 0.8232 GB, free: 3.727 MB / 0.5607 GB Notification: Performance of NFScalarize.scalarize: time 0.007066/1.057, allocations: 2.768 MB / 0.8259 GB, free: 1.914 MB / 0.5607 GB Notification: Performance of NFVerifyModel.verify: time 0.01463/1.071, allocations: 4.691 MB / 0.8305 GB, free: 14.55 MB / 0.5763 GB Notification: Performance of NFConvertDAE.convert: time 0.02481/1.096, allocations: 13.57 MB / 0.8438 GB, free: 5.102 MB / 0.5763 GB Notification: Performance of FrontEnd - DAE generated: time 9.788e-06/1.096, allocations: 4 kB / 0.8438 GB, free: 5.098 MB / 0.5763 GB Notification: Performance of FrontEnd: time 2.545e-06/1.096, allocations: 0.6562 kB / 0.8438 GB, free: 5.098 MB / 0.5763 GB Notification: Performance of Transformations before backend: time 0.00066/1.097, allocations: 0 / 0.8438 GB, free: 5.098 MB / 0.5763 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 475 * Number of variables: 475 Notification: Performance of Generate backend data structure: time 0.0443/1.141, allocations: 11.11 MB / 0.8546 GB, free: 10.7 MB / 0.5919 GB Notification: Performance of prepare preOptimizeDAE: time 5.753e-05/1.141, allocations: 8.031 kB / 0.8546 GB, free: 10.7 MB / 0.5919 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.006335/1.148, allocations: 1.159 MB / 0.8558 GB, free: 9.523 MB / 0.5919 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.03417/1.182, allocations: 12.55 MB / 0.868 GB, free: 13.13 MB / 0.6075 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0003275/1.182, allocations: 197.2 kB / 0.8682 GB, free: 12.95 MB / 0.6075 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0009749/1.183, allocations: 271.4 kB / 0.8685 GB, free: 12.68 MB / 0.6075 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.007609/1.191, allocations: 4.848 MB / 0.8732 GB, free: 6.324 MB / 0.6075 GB Notification: Performance of preOpt findStateOrder (simulation): time 6.421e-05/1.191, allocations: 35.69 kB / 0.8732 GB, free: 6.289 MB / 0.6075 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0004003/1.191, allocations: 142.2 kB / 0.8734 GB, free: 6.152 MB / 0.6075 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.0001395/1.191, allocations: 107.8 kB / 0.8735 GB, free: 6.047 MB / 0.6075 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.002541/1.194, allocations: 1.421 MB / 0.8749 GB, free: 4.625 MB / 0.6075 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.04901/1.243, allocations: 27.56 MB / 0.9018 GB, free: 8.234 MB / 0.6388 GB Notification: Performance of preOpt comSubExp (simulation): time 0.005182/1.248, allocations: 4.345 MB / 0.906 GB, free: 1.965 MB / 0.6388 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.003495/1.252, allocations: 2.242 MB / 0.9082 GB, free: 15.08 MB / 0.6544 GB Notification: Performance of preOpt evalFunc (simulation): time 0.000253/1.252, allocations: 123.9 kB / 0.9083 GB, free: 14.96 MB / 0.6544 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0003005/1.252, allocations: 330.2 kB / 0.9087 GB, free: 14.62 MB / 0.6544 GB Notification: Performance of pre-optimization done (n=230): time 8.526e-06/1.252, allocations: 7.984 kB / 0.9087 GB, free: 14.62 MB / 0.6544 GB Notification: Performance of matching and sorting (n=230): time 0.01873/1.271, allocations: 4.346 MB / 0.9129 GB, free: 10.27 MB / 0.6544 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.004627/1.276, allocations: 5.512 MB / 0.9183 GB, free: 3.453 MB / 0.6544 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.03363/1.309, allocations: 12.21 MB / 0.9302 GB, free: 7.297 MB / 0.67 GB Notification: Performance of collectPreVariables (initialization): time 0.000942/1.31, allocations: 109.7 kB / 0.9303 GB, free: 7.184 MB / 0.67 GB Notification: Performance of collectInitialEqns (initialization): time 0.005888/1.316, allocations: 2.642 MB / 0.9329 GB, free: 4.605 MB / 0.67 GB Notification: Performance of collectInitialBindings (initialization): time 0.001695/1.318, allocations: 0.8835 MB / 0.9338 GB, free: 3.746 MB / 0.67 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.01082/1.329, allocations: 2.656 MB / 0.9364 GB, free: 1.074 MB / 0.67 GB Notification: Performance of setup shared object (initialization): time 0.0001181/1.329, allocations: 305.1 kB / 0.9366 GB, free: 0.7734 MB / 0.67 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.006342/1.335, allocations: 2.526 MB / 0.9391 GB, free: 14.24 MB / 0.6857 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.0063/1.342, allocations: 3.214 MB / 0.9423 GB, free: 10.99 MB / 0.6857 GB Notification: Performance of analyzeInitialSystem (initialization): time 0.007166/1.349, allocations: 4.228 MB / 0.9464 GB, free: 6.688 MB / 0.6857 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 2.052e-05/1.349, allocations: 0 / 0.9464 GB, free: 6.688 MB / 0.6857 GB Notification: Performance of matching and sorting (n=1231) (initialization): time 0.0164/1.365, allocations: 8.441 MB / 0.9546 GB, free: 14.18 MB / 0.7013 GB Notification: Performance of prepare postOptimizeDAE: time 3.585e-05/1.365, allocations: 12 kB / 0.9546 GB, free: 14.16 MB / 0.7013 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 2.747e-05/1.365, allocations: 4 kB / 0.9546 GB, free: 14.16 MB / 0.7013 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.00207/1.368, allocations: 0.6683 MB / 0.9553 GB, free: 13.49 MB / 0.7013 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.005792/1.373, allocations: 1.806 MB / 0.9571 GB, free: 11.68 MB / 0.7013 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.00958/1.383, allocations: 6.156 MB / 0.9631 GB, free: 5.402 MB / 0.7013 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.01073/1.394, allocations: 0.6145 MB / 0.9637 GB, free: 4.781 MB / 0.7013 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.001213/1.395, allocations: 311.9 kB / 0.964 GB, free: 4.477 MB / 0.7013 GB Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 11 * Number of states: 0 () * Number of discrete variables: 12 (staCy.valve_dp_nom3_1.table1.tableID,staCy.valve_IP_control.table1.tableID,staCy.valve_dp_nom2_1.table1.tableID,staCy.valve_IP3.table1.tableID,staCy.valve_IP1.table1.tableID,staCy.valve_LP1.table1.tableID,staCy.valve_LP2.table1.tableID,staCy.valve_dp_nom.table1.tableID,staCy.valve_LP3.table1.tableID,staCy.valve_IP2.table1.tableID,staCy.boiler.table2.tableID,staCy.boiler.table1.tableID) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (1145): * Single equations (assignments): 1144 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 1 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 0 systems * Non-linear torn systems (#iteration vars, #inner vars): 1 system {(1,86)} Notification: Performance of prepare postOptimizeDAE: time 0.006316/1.401, allocations: 2.304 MB / 0.9662 GB, free: 2.164 MB / 0.7013 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.007007/1.408, allocations: 1.065 MB / 0.9673 GB, free: 1.086 MB / 0.7013 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.004105/1.412, allocations: 1.581 MB / 0.9688 GB, free: 15.48 MB / 0.7169 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 5.875e-05/1.412, allocations: 68 kB / 0.9689 GB, free: 15.41 MB / 0.7169 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 6.687e-05/1.413, allocations: 60.31 kB / 0.9689 GB, free: 15.35 MB / 0.7169 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 5.482e-05/1.413, allocations: 63.97 kB / 0.969 GB, free: 15.29 MB / 0.7169 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.04523/1.458, allocations: 29.56 MB / 0.9978 GB, free: 0.9844 MB / 0.7325 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 5.131e-05/1.458, allocations: 44 kB / 0.9979 GB, free: 0.9414 MB / 0.7325 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.0009456/1.459, allocations: 403.2 kB / 0.9983 GB, free: 0.5469 MB / 0.7325 GB Notification: Performance of postOpt tearingSystem (simulation): time 5.011e-05/1.459, allocations: 60 kB / 0.9983 GB, free: 500 kB / 0.7325 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0001494/1.459, allocations: 99.98 kB / 0.9984 GB, free: 400 kB / 0.7325 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 7.125e-05/1.459, allocations: 87.59 kB / 0.9985 GB, free: 312 kB / 0.7325 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 4.563e-05/1.459, allocations: 75.69 kB / 0.9986 GB, free: 236 kB / 0.7325 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.007011/1.466, allocations: 4.923 MB / 1.003 GB, free: 10.65 MB / 0.7482 GB Notification: Performance of postOpt removeConstants (simulation): time 0.0048/1.471, allocations: 2.462 MB / 1.006 GB, free: 8.156 MB / 0.7482 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001005/1.472, allocations: 115.9 kB / 1.006 GB, free: 8.043 MB / 0.7482 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.002536/1.475, allocations: 79.98 kB / 1.006 GB, free: 7.965 MB / 0.7482 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.0002807/1.475, allocations: 302.6 kB / 1.006 GB, free: 7.668 MB / 0.7482 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0001192/1.475, allocations: 123.9 kB / 1.006 GB, free: 7.547 MB / 0.7482 GB Notification: Performance of sorting global known variables: time 0.01536/1.49, allocations: 7.994 MB / 1.014 GB, free: 15.61 MB / 0.7638 GB Notification: Performance of sort global known variables: time 2.054e-06/1.49, allocations: 0 / 1.014 GB, free: 15.61 MB / 0.7638 GB Notification: Performance of remove unused functions: time 0.009623/1.5, allocations: 1.992 MB / 1.016 GB, free: 13.62 MB / 0.7638 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 210 * Number of states: 0 () * Number of discrete variables: 12 (staCy.boiler.table1.tableID,staCy.boiler.table2.tableID,staCy.valve_IP2.table1.tableID,staCy.valve_LP3.table1.tableID,staCy.valve_dp_nom.table1.tableID,staCy.valve_LP2.table1.tableID,staCy.valve_LP1.table1.tableID,staCy.valve_IP1.table1.tableID,staCy.valve_IP3.table1.tableID,staCy.valve_dp_nom2_1.table1.tableID,staCy.valve_IP_control.table1.tableID,staCy.valve_dp_nom3_1.table1.tableID) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (224): * Single equations (assignments): 212 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 12 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/ClaRa/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.003426/1.504, allocations: 1.426 MB / 1.018 GB, free: 12.77 MB / 0.7638 GB Notification: Performance of simCode: created initialization part: time 0.01205/1.516, allocations: 5.167 MB / 1.023 GB, free: 7.586 MB / 0.7638 GB Notification: Performance of simCode: created event and clocks part: time 3.915e-05/1.516, allocations: 12.19 kB / 1.023 GB, free: 7.574 MB / 0.7638 GB Notification: Performance of simCode: created simulation system equations: time 0.001882/1.518, allocations: 0.9355 MB / 1.024 GB, free: 6.648 MB / 0.7638 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01665/1.534, allocations: 1.04 MB / 1.025 GB, free: 5.609 MB / 0.7638 GB Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.03821/1.572, allocations: 17.85 MB / 1.042 GB, free: 3.098 MB / 0.7794 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.3688/1.941, allocations: 4.404 MB / 1.046 GB, free: 306.2 MB / 0.7794 GB Notification: Performance of simCode: alias equations: time 0.005341/1.947, allocations: 1.191 MB / 1.047 GB, free: 306.1 MB / 0.7794 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.002322/1.949, allocations: 0.5959 MB / 1.048 GB, free: 306.1 MB / 0.7794 GB Notification: Performance of SimCode: time 7.61e-07/1.949, allocations: 0 / 1.048 GB, free: 306.1 MB / 0.7794 GB Notification: Performance of Templates: time 0.1212/2.07, allocations: 65.18 MB / 1.112 GB, free: 268.7 MB / 0.7794 GB make -j1 -f ClaRa_ClaRa.StaticCycles.Check.TestStacy6.makefile make -j1 -f ClaRa_ClaRa.StaticCycles.Check.TestStacy6.makefile clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ClaRa_ClaRa_StaticCycles_Check_TestStacy6 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=1 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ClaRa_ClaRa.StaticCycles.Check.TestStacy6.o ClaRa_ClaRa.StaticCycles.Check.TestStacy6.c clang -Os -fPIC -falign-functions -mfpmath=sse -fno-dollars-in-identifiers -Wno-parentheses-equality -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c" -I"/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc" -I. -DOPENMODELICA_XML_FROM_FILE_AT_RUNTIME -DOMC_MODEL_PREFIX=ClaRa_ClaRa_StaticCycles_Check_TestStacy6 -DOMC_NUM_MIXED_SYSTEMS=0 -DOMC_NUM_LINEAR_SYSTEMS=0 -DOMC_NUM_NONLINEAR_SYSTEMS=1 -DOMC_NDELAY_EXPRESSIONS=0 -DOMC_NVAR_STRING=0 -c -o ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.o ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c In file included from ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:7: ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:39:136: error: use of undeclared identifier 'ModelicaFormatMessage' return TILMedia_createExternalObject_errorInterface(objectType, mixtureName, flags, xi, _nc, condensingIndex, instanceName, (void*)ModelicaFormatMessage, (void*)ModelicaFormatError, 0); ^ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:39:166: error: use of undeclared identifier 'ModelicaFormatError' return TILMedia_createExternalObject_errorInterface(objectType, mixtureName, flags, xi, _nc, condensingIndex, instanceName, (void*)ModelicaFormatMessage, (void*)ModelicaFormatError, 0); ^ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:74:51: error: use of undeclared identifier 'ModelicaFormatMessage' TILMedia_redirectModelicaFormatMessage((void*)ModelicaFormatMessage); ^ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:75:49: error: use of undeclared identifier 'ModelicaFormatError' TILMedia_redirectModelicaFormatError((void*)ModelicaFormatError); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:22:75: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:87:78: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:51:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:86:77: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:80:75: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:87:78: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:109:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:86:77: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:138:75: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:87:78: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:167:74: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, _vleFluidPointer_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:86:77: note: passing argument to parameter here double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:970:125: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _externalObject_ext = TILMedia_createExternalObject(MMC_STRINGDATA(_objectType), MMC_STRINGDATA(_mediumName), _flags_ext, (const double*) _xi_c89, _nc_ext, _condensingIndex_ext, MMC_STRINGDATA(_instanceName)); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:35:105: note: passing argument to parameter 'xi' here void* TILMedia_createExternalObject(const char* objectType, const char* mixtureName, int flags, double* xi, int _nc, int condensingIndex, const char* instanceName) { ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:1011:72: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _d_bubble_ext = TILMedia_VLEFluidFunctions_bubbleDensity_pxi(_p_ext, (const double*) _xi_c89, MMC_STRINGDATA(_vleFluidName), _nc_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:9:68: note: passing argument to parameter here double TILMedia_VLEFluidFunctions_bubbleDensity_pxi(double, double*, const char*, int); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:1038:81: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_bubble_ext = TILMedia_VLEFluidFunctions_bubbleSpecificEnthalpy_pxi(_p_ext, (const double*) _xi_c89, MMC_STRINGDATA(_vleFluidName), _nc_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:8:77: note: passing argument to parameter here double TILMedia_VLEFluidFunctions_bubbleSpecificEnthalpy_pxi(double, double*, const char*, int); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:1067:68: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _d_ext = TILMedia_VLEFluidFunctions_density_phxi(_p_ext, _h_ext, (const double*) _xi_c89, MMC_STRINGDATA(_vleFluidName), _nc_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:7:71: note: passing argument to parameter here double TILMedia_VLEFluidFunctions_density_phxi(double, double, double*,const char*, int); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:1098:77: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi(_p_ext, _T_ext, (const double*) _xi_c89, MMC_STRINGDATA(_vleFluidName), _nc_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:6:80: note: passing argument to parameter here double TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi(double, double, double*,const char*, int); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:1129:77: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _h_ext = TILMedia_VLEFluidFunctions_specificEnthalpy_psxi(_p_ext, _s_ext, (const double*) _xi_c89, MMC_STRINGDATA(_vleFluidName), _nc_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:5:80: note: passing argument to parameter here double TILMedia_VLEFluidFunctions_specificEnthalpy_psxi(double, double, double*,const char*, int); ^ ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.c:1160:76: warning: passing 'const double *' to parameter of type 'double *' discards qualifiers [-Wincompatible-pointer-types-discards-qualifiers] _s_ext = TILMedia_VLEFluidFunctions_specificEntropy_phxi(_p_ext, _h_ext, (const double*) _xi_c89, MMC_STRINGDATA(_vleFluidName), _nc_ext); ^~~~~~~~~~~~~~~~~~~~~~~ ./ClaRa_ClaRa.StaticCycles.Check.TestStacy6_includes.h:4:79: note: passing argument to parameter here double TILMedia_VLEFluidFunctions_specificEntropy_phxi(double, double, double*,const char*, int); ^ 13 warnings and 4 errors generated. make: *** [: ClaRa_ClaRa.StaticCycles.Check.TestStacy6_functions.o] Error 1