Environment - simulationEnvironment: startTime=1.296e+06 stopTime=1.3824e+06 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.Examples.Tutorial.CDL.System1 -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 1296000.000000 | | | | not (pumRad.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumRad.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in System1.pumRad: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 1296000.000000 | | | | pumRad.per.haveWMot_nominal or not (pumRad.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumRad.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in System1.pumRad: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 1296000.000000 | | | | not (pumBoi.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pumBoi.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in System1.pumBoi: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 1296000.000000 | | | | pumBoi.per.haveWMot_nominal or not (pumBoi.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pumBoi.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in System1.pumBoi: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | The following assertion has been violated at time 1296881.280000 | | | | valBoi.res3.y >= 0.0 and valBoi.res3.y <= 1.0 assert | info | Variable violating min/max constraint: 0.0 <= valBoi.res3.y <= 1.0, has value: -2.22045e-16 assert | info | The following assertion has been violated at time 1296881.280000 | | | | valBoi.filter.y >= 0.0 and valBoi.filter.y <= 1.0 assert | info | Variable violating min/max constraint: 0.0 <= valBoi.filter.y <= 1.0, has value: 1 assert | info | The following assertion has been violated at time 1296984.960000 | | | | valRad.res3.y >= 0.0 and valRad.res3.y <= 1.0 assert | info | Variable violating min/max constraint: 0.0 <= valRad.res3.y <= 1.0, has value: -2.22045e-16 assert | info | The following assertion has been violated at time 1296984.960000 | | | | valRad.filter.y >= 0.0 and valRad.filter.y <= 1.0 assert | info | Variable violating min/max constraint: 0.0 <= valRad.filter.y <= 1.0, has value: 1 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0494044s reading init.xml | | | | | | 0.00385614s reading info.xml | | | | | | 0.000919674s [ 0.5%] pre-initialization | | | | | | 0.0333406s [ 19.2%] initialization | | | | | | 1.4447e-05s [ 0.0%] steps | | | | | | 0.00415926s [ 2.4%] solver (excl. callbacks) | | | | | | 0.00522262s [ 3.0%] creating output-file | | | | | | 0.00115791s [ 0.7%] event-handling | | | | | | 0.0304919s [ 17.5%] overhead | | | | | | 0.0985445s [ 56.7%] simulation | | | | | | 0.173851s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 558 steps taken | | | | | | 716 calls of functionODE | | | | | | 64 evaluations of jacobian | | | | | | 7 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00609419s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.