Environment - simulationEnvironment: startTime=0 stopTime=1200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.48 Regular simulation: ./Buildings_10_Buildings.Fluid.HeatExchangers.Validation.PrescribedOutlet -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00707415s reading init.xml | | | | | | 0.000620503s reading info.xml | | | | | | 0.000350998s [ 1.7%] pre-initialization | | | | | | 0.000148318s [ 0.7%] initialization | | | | | | 1.744e-06s [ 0.0%] steps | | | | | | 0.00100488s [ 4.9%] solver (excl. callbacks) | | | | | | 0.0015542s [ 7.6%] creating output-file | | | | | | 0.000440252s [ 2.2%] event-handling | | | | | | 0.00551049s [ 27.0%] overhead | | | | | | 0.0114018s [ 55.9%] simulation | | | | | | 0.0204126s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 318 steps taken | | | | | | 424 calls of functionODE | | | | | | 116 evaluations of jacobian | | | | | | 10 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000133161s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.