Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 Regular simulation: ./Buildings_1.6_Buildings.Fluid.Movers.Validation.PowerEuler -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump_dp.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in PowerEuler.pump_dp: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in PowerEuler.pump_dp: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pump_m_flow.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning in PowerEuler.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in PowerEuler.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.018585s reading init.xml | | | | | | 0.00191942s reading info.xml | | | | | | 9.9616e-05s [ 0.3%] pre-initialization | | | | | | 0.000819897s [ 2.5%] initialization | | | | | | 4.949e-06s [ 0.0%] steps | | | | | | 0.000723589s [ 2.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000358581s [ 1.1%] event-handling | | | | | | 0.00894059s [ 27.4%] overhead | | | | | | 0.02172s [ 66.5%] simulation | | | | | | 0.0326672s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 72 steps taken | | | | | | 89 calls of functionODE | | | | | | 57 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00011598s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.