Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_1.6_Buildings.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo", uses=false) Using package Buildings with version 12.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator") translateModel(Buildings.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001325/0.001325, allocations: 111.3 kB / 15.23 MB, free: 0.6602 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001531/0.001531, allocations: 189.2 kB / 16.13 MB, free: 6.656 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.38/1.38, allocations: 222.9 MB / 239.8 MB, free: 4.602 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/package.mo): time 2.798/2.798, allocations: 472.6 MB / 0.7447 GB, free: 4.965 MB / 0.5919 GB Notification: Performance of FrontEnd - loaded program: time 0.001311/0.001311, allocations: 65.5 kB / 0.9114 GB, free: 33.65 MB / 0.7169 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3427/0.3441, allocations: 159.9 MB / 1.068 GB, free: 10.88 MB / 0.8262 GB Notification: Performance of NFInst.instantiate(Buildings.Fluid.HeatPumps.ModularReversible.Examples.AirToWater2D_OneRoomRadiator): time 1.04/1.384, allocations: 352.1 MB / 1.411 GB, free: 8.789 MB / 1.029 GB Notification: Performance of NFInst.instExpressions: time 0.08618/1.47, allocations: 48.87 MB / 1.459 GB, free: 1.117 MB / 1.061 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.01564/1.486, allocations: 234.7 kB / 1.459 GB, free: 0.8867 MB / 1.061 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/Characteristics/efficiencyParameters_yMot.mo:5:3-6:45:writable] Error: Could not evaluate structural parameter (or constant): pumHeaPum.eff.per.pressure.V_flow which gives dimensions of array: y. Array dimensions must be known at compile time. Notification: Performance of FrontEnd: time 0.02232/1.508, allocations: 4.549 MB / 1.464 GB, free: 12.33 MB / 1.076 GB