Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Validation.PumpCurveDerivatives -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump1.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (forcedPump1.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or forcedPump1.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in PumpCurveDerivatives.forcedPump1: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | forcedPump1.per.haveWMot_nominal or not (forcedPump1.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or forcedPump1.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in PumpCurveDerivatives.forcedPump1: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. assert | info | The following assertion has been violated at time 0.423800 | | | | pump1.eta >= 0.0 assert | info | Variable violating min constraint: 0.0 <= pump1.eta, has value: -8.54211e-05 assert | info | The following assertion has been violated at time 0.423800 | | | | pump1.heaDis.etaHyd >= 0.0 assert | info | Variable violating min constraint: 0.0 <= pump1.heaDis.etaHyd, has value: -555.282 assert | info | The following assertion has been violated at time 0.423800 | | | | pump1.eff.yMot >= 0.0 assert | info | Variable violating min constraint: 0.0 <= pump1.eff.yMot, has value: -6.77122e-06 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0197924s reading init.xml | | | | | | 0.00180772s reading info.xml | | | | | | 0.000110137s [ 0.3%] pre-initialization | | | | | | 0.000851837s [ 2.6%] initialization | | | | | | 3.657e-06s [ 0.0%] steps | | | | | | 0.00101118s [ 3.1%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000345957s [ 1.0%] event-handling | | | | | | 0.00796864s [ 24.2%] overhead | | | | | | 0.0226748s [ 68.8%] simulation | | | | | | 0.0329662s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 252 steps taken | | | | | | 381 calls of functionODE | | | | | | 51 evaluations of jacobian | | | | | | 24 error test failures | | | | | | 0 convergence test failures | | | | | | 7.5455e-05s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.