Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.FMI.Validation.HeaterFan_noReverseFlow -abortSlowSimulation -alarm=480 -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in HeaterFan_noReverseFlow.floMac.com: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | false assert | warning | *** Warning in HeaterFan_noReverseFlow.floMac.com: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00957845s reading init.xml | | | | | | 0.00118705s reading info.xml | | | | | | 0.000110448s [ 1.6%] pre-initialization | | | | | | 0.000268984s [ 3.8%] initialization | | | | | | 4.41e-07s [ 0.0%] steps | | | | | | 5.4111e-05s [ 0.8%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.9954e-05s [ 0.3%] event-handling | | | | | | 0.00316249s [ 44.7%] overhead | | | | | | 0.00345234s [ 48.8%] simulation | | | | | | 0.00706877s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 5000 steps taken | | | | | | 5000 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.