Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr SolarTherm_SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.Exchanger.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo", uses=false) Using package SolarTherm with version 0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: "" <> buildModelFMU(SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.Exchanger,fileNamePrefix="SolarTherm_SolarTherm_Models_PowerBlocks_sCO2Cycle_OffDesign_Exchanger",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(SolarTherm.Models.PowerBlocks.sCO2Cycle.OffDesign.Exchanger,fileNamePrefix="SolarTherm_SolarTherm_Models_PowerBlocks_sCO2Cycle_OffDesign_Exchanger",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001169/0.001169, allocations: 111.3 kB / 15.23 MB, free: 0.6602 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001379/0.001379, allocations: 193.1 kB / 16.13 MB, free: 6.66 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.61/1.61, allocations: 205.1 MB / 222 MB, free: 4.75 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/package.mo): time 0.1127/0.1127, allocations: 24.84 MB / 294.2 MB, free: 12.58 MB / 254.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.00138/0.00138, allocations: 68.62 kB / 357.3 MB, free: 8.445 MB / 254.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1224/0.1238, allocations: 52.28 MB / 409.6 MB, free: 4.121 MB / 302.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SolarTherm 0.2.0-master/Models/PowerBlocks/sCO2Cycle/OffDesign/Exchanger.mo:8:3-8:97:writable] Error: Class SolarTherm.Types.Conductance not found in scope Exchanger. Notification: Performance of FrontEnd: time 0.003441/0.1273, allocations: 1.604 MB / 411.2 MB, free: 2.5 MB / 302.1 MB