/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithLatentGain_res.mat --tempDir=temp_Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain_fmu --startTime=0 --stopTime=604800 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithLatentGain_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.intGai.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.intGai.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.outdoorTemp.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.outdoorTemp.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.reference.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.reference.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.senMasFra.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.tableSolRadWindow.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.tableSolRadWindow.tableName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.ventRate.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain.ventRate.tableName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.ThermalZones.ReducedOrder.Validation.RoomWithLatentGain/temp_Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain_fmu/model-q3bh8ra9/temp/0001_Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain (logStatusError): fmi2SetTime: Illegal model exchange call sequence. fmi2SetTime is not allowed in model_state_terminated state. error: [doStep] fmi2_setTime failed for FMU "model.root.Buildings_latest_Buildings_ThermalZones_ReducedOrder_Validation_RoomWithLatentGain"