Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.04 Regular simulation: ./Buildings_latest_Buildings.Fluid.FixedResistances.Examples.FlowJunction -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00453644s reading init.xml | | | | | | 0.000445877s reading info.xml | | | | | | 0.000320381s [ 3.1%] pre-initialization | | | | | | 0.000145924s [ 1.4%] initialization | | | | | | 1.102e-06s [ 0.0%] steps | | | | | | 0.001053s [ 10.1%] solver (excl. callbacks) | | | | | | 0.00112623s [ 10.8%] creating output-file | | | | | | 0.000299339s [ 2.9%] event-handling | | | | | | 0.00167489s [ 16.1%] overhead | | | | | | 0.00578509s [ 55.6%] simulation | | | | | | 0.010406s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 292 steps taken | | | | | | 448 calls of functionODE | | | | | | 111 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 1 convergence test failures | | | | | | 0.000153522s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.