Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum1.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox.pum1: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pum1.per.haveWMot_nominal or not (pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum1.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox.pum1: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | not (pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum2.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox.pum2: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. assert | warning | The following assertion has been violated during initialization at time 0.000000 | | | | pum2.per.haveWMot_nominal or not (pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum2.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve) assert | warning | *** Warning in Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox.pum2: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve. LOG_SUCCESS | info | The initialization finished successfully without homotopy method. assert | info | The following assertion has been violated at time 300.000000 | | | | pum1.eff.yMot >= 0.0 assert | info | Variable violating min constraint: 0.0 <= pum1.eff.yMot, has value: -2.13331e-11 assert | info | The following assertion has been violated at time 650.000000 | | | | pum2.eff.yMot >= 0.0 assert | info | Variable violating min constraint: 0.0 <= pum2.eff.yMot, has value: -6.38028e-11 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0212244s reading init.xml | | | | | | 0.00223891s reading info.xml | | | | | | 0.000883717s [ 2.6%] pre-initialization | | | | | | 0.000566312s [ 1.6%] initialization | | | | | | 3.096e-06s [ 0.0%] steps | | | | | | 0.00100585s [ 2.9%] solver (excl. callbacks) | | | | | | 0.00230721s [ 6.7%] creating output-file | | | | | | 0.00102444s [ 3.0%] event-handling | | | | | | 0.0100124s [ 29.0%] overhead | | | | | | 0.0186911s [ 54.2%] simulation | | | | | | 0.0344942s [100.0%] total | | | | | events | | | | | | 8 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 137 steps taken | | | | | | 137 calls of functionODE | | | | | | 130 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000398845s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.