/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox_res.mat --tempDir=temp_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox_fmu --startTime=0 --stopTime=1000 --timeout=50 --tolerance=1e-06 Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox/temp_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox_fmu/model-gezcturv/temp/0001_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311: The following assertion has been violated at time 0.000000 pum2.eff.yMot >= 0.0 assert | warning | Variable violating min constraint: 0.0 <= pum2.eff.yMot, has value: -0.155738 info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox_res.mat (bufferSize=1) info: Parameter model.root.Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox.setMasFlo2.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox.setMasFlo2.tableName will not be stored in the result file, because the signal type is not supported assert | debug | Solving non-linear system 963 failed at time=308.019999999628. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox/temp_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox_fmu/model-gezcturv/temp/0001_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable floSwiBox.con.truFalHol.y assert | debug | Solving non-linear system 963 failed at time=308.019999999628. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox/temp_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox_fmu/model-gezcturv/temp/0001_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox" assert | debug | Solving non-linear system 963 failed at time=308.019999999628. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Experimental.DHC.EnergyTransferStations.Combined.Subsystems.Validation.SwitchBox/temp_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox_fmu/model-gezcturv/temp/0001_Buildings_latest_Buildings_Experimental_DHC_EnergyTransferStations_Combined_Subsystems_Validation_SwitchBox (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable floSwiBox.con.truFalHol.y info: Final Statistics for 'model.root': NumSteps = 8021 NumRhsEvals = 8022 NumLinSolvSetups = 402 NumNonlinSolvIters = 8021 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 info: 1 warnings info: 6 errors