/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Utilities.Plotters.Examples.SingleZoneVAV_res.mat --tempDir=temp_Buildings_9_Buildings_Utilities_Plotters_Examples_SingleZoneVAV_fmu --startTime=1.5552e+07 --stopTime=1.5984e+07 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Utilities_Plotters_Examples_SingleZoneVAV.fmu stdout | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. stdout | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. stdout | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. stdout | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: hvac.cooCoi.m1_flow + hvac.ideVal.preMasFlo.m_flow error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/temp_Buildings_9_Buildings_Utilities_Plotters_Examples_SingleZoneVAV_fmu/model-48hnyc1t/temp/0001_Buildings_9_Buildings_Utilities_Plotters_Examples_SingleZoneVAV (logFmi2Call): internalEventUpdate: terminated by an assertion. assert | debug | division by zero at time 0, (a=0) / (b=0), where divisor b expression is: hvac.cooCoi.m1_flow + hvac.ideVal.preMasFlo.m_flow error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/temp_Buildings_9_Buildings_Utilities_Plotters_Examples_SingleZoneVAV_fmu/model-48hnyc1t/temp/0001_Buildings_9_Buildings_Utilities_Plotters_Examples_SingleZoneVAV (logFmi2Call): internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Buildings_9_Buildings_Utilities_Plotters_Examples_SingleZoneVAV" stdout | info | Wrote plot file "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html". error: [initialize] Initialization of system "model.root" failed error: [simulate] Model "model" is in wrong model state info: 0 warnings info: 5 errors