/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop_res.mat --tempDir=temp_Buildings_9_Buildings_Fluid_Boilers_Examples_BoilerPolynomialClosedLoop_fmu --startTime=0 --stopTime=14400 --timeout=50 --tolerance=1e-06 Buildings_9_Buildings_Fluid_Boilers_Examples_BoilerPolynomialClosedLoop.fmu warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop/temp_Buildings_9_Buildings_Fluid_Boilers_Examples_BoilerPolynomialClosedLoop_fmu/model-s80y8n2p/temp/0001_Buildings_9_Buildings_Fluid_Boilers_Examples_BoilerPolynomialClosedLoop (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 pumLoa.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. warning: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop/temp_Buildings_9_Buildings_Fluid_Boilers_Examples_BoilerPolynomialClosedLoop_fmu/model-s80y8n2p/temp/0001_Buildings_9_Buildings_Fluid_Boilers_Examples_BoilerPolynomialClosedLoop (logStatusWarning): /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348: The following assertion has been violated during initialization at time 0.000000 pumBoi.nominalValuesDefineDefaultPressureCurve assert | warning | *** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning. info: maximum step size for 'model.root': 0.001000 info: Result file: Buildings_9_Buildings.Fluid.Boilers.Examples.BoilerPolynomialClosedLoop_res.mat (bufferSize=1) error: [operator()] Timeout occurred during simulation info: 2 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 246405 NumRhsEvals = 246408 NumLinSolvSetups = 12323 NumNonlinSolvIters = 246407 NumNonlinSolvConvFails = 0 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21